This page is part of the Quality Improvement Core Framework (v6.0.0: STU6 (v6.0.0)) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-devicerequest | Version: 6.0.0 | |||
Active as of 2019-07-11 | Computable Name: QICoreDeviceRequest |
Profile of DeviceRequest for decision support/quality metrics. Defines the core set of elements and extensions for quality rule and measure authors.
The FHIR R4 and the QI-Core DeviceRequest profile describes the request to use of a device by a patient. The device may be any pertinent device specified in the Device resource. Examples of devices that may be requested include a wheelchair, hearing aids, or an insulin pump. The request may lead to the dispensing of the device to the patient or for use by the patient. Orders or recommendations for use of a device for a patient use the ServiceRequest resource.
To create an expression specifically requesting information that a DeviceRequest intentionally did not occur for a medical, patient or system reason, use the profile QICore-Devicenotrequested.
The following example illustrates the use of DeviceRequest:
define "Device Indicating Frailty":
[DeviceRequest: "Frailty Device"] FrailtyDeviceOrder
where FrailtyDeviceOrder.status in { 'active', 'on-hold', 'completed' }
and FrailtyDeviceOrder.intent in { 'order', 'original-order', 'reflex-order', 'filler-order', 'instance-order' }
General DeviceRequest Example |
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from DeviceRequest
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceRequest | DeviceRequest | |||
modifierExtension:doNotPerform | ?! | 0..1 | R5 DeviceRequest.doNotPerform | (QI-Core) Extension |
value[x] | 1..1 | boolean | (QI-Core) Value of extension Fixed Value: false | |
identifier | 0..* | Identifier | (QI-Core) External Request identifier | |
status | 0..1 | code | (QI-Core) draft | active | on-hold | revoked | completed | entered-in-error | unknown | |
intent | 1..1 | code | (QI-Core) proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option | |
code[x] | 1..1 | Reference(Device), CodeableConcept | (QI-Core) Device requested Binding: FHIRDeviceTypes (preferred) | |
subject | 1..1 | Reference(QICore Patient) | (QI-Core) Focus of request | |
authoredOn | 0..1 | dateTime | (QI-Core) When recorded | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
DeviceRequest.code[x] | preferred | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceRequest | 0..* | DeviceRequest | Medical device request | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Slices for modifierExtension | ?! | 0..* | Extension | Extension Slice: Unordered, Open by value:url |
modifierExtension:doNotPerform | ?! | 0..1 | R5 DeviceRequest.doNotPerform | (QI-Core) Extension |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform" | |
value[x] | 1..1 | boolean | (QI-Core) Value of extension Fixed Value: false | |
identifier | Σ | 0..* | Identifier | (QI-Core) External Request identifier |
status | ?!Σ | 0..1 | code | (QI-Core) draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. |
intent | ?!Σ | 1..1 | code | (QI-Core) proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. |
code[x] | Σ | 1..1 | (QI-Core) Device requested Binding: FHIRDeviceTypes (preferred) | |
codeReference | Reference(Device) | |||
codeCodeableConcept | CodeableConcept | |||
subject | Σ | 1..1 | Reference(QICore Patient) | (QI-Core) Focus of request |
authoredOn | Σ | 0..1 | dateTime | (QI-Core) When recorded |
Documentation for this format |
Path | Conformance | ValueSet | URI |
DeviceRequest.status | required | RequestStatushttp://hl7.org/fhir/ValueSet/request-status|4.0.1 from the FHIR Standard | |
DeviceRequest.intent | required | RequestIntenthttp://hl7.org/fhir/ValueSet/request-intent|4.0.1 from the FHIR Standard | |
DeviceRequest.code[x] | preferred | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | DeviceRequest | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | DeviceRequest | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | DeviceRequest | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
DeviceRequest | 0..* | DeviceRequest | Medical device request | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
Slices for modifierExtension | ?! | 0..* | Extension | Extension Slice: Unordered, Open by value:url | ||||
modifierExtension:doNotPerform | ?! | 0..1 | R5 DeviceRequest.doNotPerform | (QI-Core) Extension | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform" | |||||
value[x] | 1..1 | boolean | (QI-Core) Value of extension Fixed Value: false | |||||
identifier | Σ | 0..* | Identifier | (QI-Core) External Request identifier | ||||
instantiatesCanonical | Σ | 0..* | canonical(ActivityDefinition | PlanDefinition) | Instantiates FHIR protocol or definition | ||||
instantiatesUri | Σ | 0..* | uri | Instantiates external protocol or definition | ||||
basedOn | Σ | 0..* | Reference(Resource) | What request fulfills | ||||
priorRequest | Σ | 0..* | Reference(Resource) | What request replaces | ||||
groupIdentifier | Σ | 0..1 | Identifier | Identifier of composite request | ||||
status | ?!Σ | 0..1 | code | (QI-Core) draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. | ||||
intent | ?!Σ | 1..1 | code | (QI-Core) proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. | ||||
priority | Σ | 0..1 | code | routine | urgent | asap | stat Binding: RequestPriority (required): Identifies the level of importance to be assigned to actioning the request. | ||||
code[x] | Σ | 1..1 | (QI-Core) Device requested Binding: FHIRDeviceTypes (preferred) | |||||
codeReference | Reference(Device) | |||||||
codeCodeableConcept | CodeableConcept | |||||||
parameter | 0..* | BackboneElement | Device details | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | 0..1 | CodeableConcept | Device detail Binding: (unbound) (example): A code that identifies the device detail. | |||||
value[x] | 0..1 | Value of detail | ||||||
valueCodeableConcept | CodeableConcept | |||||||
valueQuantity | Quantity | |||||||
valueRange | Range | |||||||
valueBoolean | boolean | |||||||
subject | Σ | 1..1 | Reference(QICore Patient) | (QI-Core) Focus of request | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Encounter motivating request | ||||
occurrence[x] | Σ | 0..1 | Desired time or schedule for use | |||||
occurrenceDateTime | dateTime | |||||||
occurrencePeriod | Period | |||||||
occurrenceTiming | Timing | |||||||
authoredOn | Σ | 0..1 | dateTime | (QI-Core) When recorded | ||||
requester | Σ | 0..1 | Reference(Device | Practitioner | PractitionerRole | Organization) | Who/what is requesting diagnostics | ||||
performerType | Σ | 0..1 | CodeableConcept | Filler role Binding: ParticipantRoles (example): Indicates specific responsibility of an individual within the care team, such as "Primary physician", "Team coordinator", "Caregiver", etc. | ||||
performer | Σ | 0..1 | Reference(Practitioner | PractitionerRole | Organization | CareTeam | HealthcareService | Patient | Device | RelatedPerson) | Requested Filler | ||||
reasonCode | Σ | 0..* | CodeableConcept | Coded Reason for request Binding: Condition/Problem/DiagnosisCodes (example): Diagnosis or problem codes justifying the reason for requesting the device. | ||||
reasonReference | Σ | 0..* | Reference(Condition | Observation | DiagnosticReport | DocumentReference) | Linked Reason for request | ||||
insurance | 0..* | Reference(Coverage | ClaimResponse) | Associated insurance coverage | |||||
supportingInfo | 0..* | Reference(Resource) | Additional clinical information | |||||
note | 0..* | Annotation | Notes or comments | |||||
relevantHistory | 0..* | Reference(Provenance) | Request provenance | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
DeviceRequest.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
DeviceRequest.status | required | RequestStatushttp://hl7.org/fhir/ValueSet/request-status|4.0.1 from the FHIR Standard | ||||
DeviceRequest.intent | required | RequestIntenthttp://hl7.org/fhir/ValueSet/request-intent|4.0.1 from the FHIR Standard | ||||
DeviceRequest.priority | required | RequestPriorityhttp://hl7.org/fhir/ValueSet/request-priority|4.0.1 from the FHIR Standard | ||||
DeviceRequest.code[x] | preferred | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard | ||||
DeviceRequest.parameter.code | example | |||||
DeviceRequest.performerType | example | ParticipantRoleshttp://hl7.org/fhir/ValueSet/participant-role from the FHIR Standard | ||||
DeviceRequest.reasonCode | example | Condition/Problem/DiagnosisCodeshttp://hl7.org/fhir/ValueSet/condition-code from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | DeviceRequest | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | DeviceRequest | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | DeviceRequest | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from DeviceRequest
Differential View
This structure is derived from DeviceRequest
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceRequest | DeviceRequest | |||
modifierExtension:doNotPerform | ?! | 0..1 | R5 DeviceRequest.doNotPerform | (QI-Core) Extension |
value[x] | 1..1 | boolean | (QI-Core) Value of extension Fixed Value: false | |
identifier | 0..* | Identifier | (QI-Core) External Request identifier | |
status | 0..1 | code | (QI-Core) draft | active | on-hold | revoked | completed | entered-in-error | unknown | |
intent | 1..1 | code | (QI-Core) proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option | |
code[x] | 1..1 | Reference(Device), CodeableConcept | (QI-Core) Device requested Binding: FHIRDeviceTypes (preferred) | |
subject | 1..1 | Reference(QICore Patient) | (QI-Core) Focus of request | |
authoredOn | 0..1 | dateTime | (QI-Core) When recorded | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
DeviceRequest.code[x] | preferred | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
DeviceRequest | 0..* | DeviceRequest | Medical device request | |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
Slices for modifierExtension | ?! | 0..* | Extension | Extension Slice: Unordered, Open by value:url |
modifierExtension:doNotPerform | ?! | 0..1 | R5 DeviceRequest.doNotPerform | (QI-Core) Extension |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform" | |
value[x] | 1..1 | boolean | (QI-Core) Value of extension Fixed Value: false | |
identifier | Σ | 0..* | Identifier | (QI-Core) External Request identifier |
status | ?!Σ | 0..1 | code | (QI-Core) draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. |
intent | ?!Σ | 1..1 | code | (QI-Core) proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. |
code[x] | Σ | 1..1 | (QI-Core) Device requested Binding: FHIRDeviceTypes (preferred) | |
codeReference | Reference(Device) | |||
codeCodeableConcept | CodeableConcept | |||
subject | Σ | 1..1 | Reference(QICore Patient) | (QI-Core) Focus of request |
authoredOn | Σ | 0..1 | dateTime | (QI-Core) When recorded |
Documentation for this format |
Path | Conformance | ValueSet | URI |
DeviceRequest.status | required | RequestStatushttp://hl7.org/fhir/ValueSet/request-status|4.0.1 from the FHIR Standard | |
DeviceRequest.intent | required | RequestIntenthttp://hl7.org/fhir/ValueSet/request-intent|4.0.1 from the FHIR Standard | |
DeviceRequest.code[x] | preferred | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | DeviceRequest | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | DeviceRequest | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | DeviceRequest | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
DeviceRequest | 0..* | DeviceRequest | Medical device request | |||||
id | Σ | 0..1 | id | Logical id of this artifact | ||||
meta | Σ | 0..1 | Meta | Metadata about the resource | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
language | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
Slices for modifierExtension | ?! | 0..* | Extension | Extension Slice: Unordered, Open by value:url | ||||
modifierExtension:doNotPerform | ?! | 0..1 | R5 DeviceRequest.doNotPerform | (QI-Core) Extension | ||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..0 | |||||||
url | 1..1 | uri | "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceRequest.doNotPerform" | |||||
value[x] | 1..1 | boolean | (QI-Core) Value of extension Fixed Value: false | |||||
identifier | Σ | 0..* | Identifier | (QI-Core) External Request identifier | ||||
instantiatesCanonical | Σ | 0..* | canonical(ActivityDefinition | PlanDefinition) | Instantiates FHIR protocol or definition | ||||
instantiatesUri | Σ | 0..* | uri | Instantiates external protocol or definition | ||||
basedOn | Σ | 0..* | Reference(Resource) | What request fulfills | ||||
priorRequest | Σ | 0..* | Reference(Resource) | What request replaces | ||||
groupIdentifier | Σ | 0..1 | Identifier | Identifier of composite request | ||||
status | ?!Σ | 0..1 | code | (QI-Core) draft | active | on-hold | revoked | completed | entered-in-error | unknown Binding: RequestStatus (required): Codes representing the status of the request. | ||||
intent | ?!Σ | 1..1 | code | (QI-Core) proposal | plan | directive | order | original-order | reflex-order | filler-order | instance-order | option Binding: RequestIntent (required): The kind of diagnostic request. | ||||
priority | Σ | 0..1 | code | routine | urgent | asap | stat Binding: RequestPriority (required): Identifies the level of importance to be assigned to actioning the request. | ||||
code[x] | Σ | 1..1 | (QI-Core) Device requested Binding: FHIRDeviceTypes (preferred) | |||||
codeReference | Reference(Device) | |||||||
codeCodeableConcept | CodeableConcept | |||||||
parameter | 0..* | BackboneElement | Device details | |||||
id | 0..1 | string | Unique id for inter-element referencing | |||||
extension | 0..* | Extension | Additional content defined by implementations | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
code | 0..1 | CodeableConcept | Device detail Binding: (unbound) (example): A code that identifies the device detail. | |||||
value[x] | 0..1 | Value of detail | ||||||
valueCodeableConcept | CodeableConcept | |||||||
valueQuantity | Quantity | |||||||
valueRange | Range | |||||||
valueBoolean | boolean | |||||||
subject | Σ | 1..1 | Reference(QICore Patient) | (QI-Core) Focus of request | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Encounter motivating request | ||||
occurrence[x] | Σ | 0..1 | Desired time or schedule for use | |||||
occurrenceDateTime | dateTime | |||||||
occurrencePeriod | Period | |||||||
occurrenceTiming | Timing | |||||||
authoredOn | Σ | 0..1 | dateTime | (QI-Core) When recorded | ||||
requester | Σ | 0..1 | Reference(Device | Practitioner | PractitionerRole | Organization) | Who/what is requesting diagnostics | ||||
performerType | Σ | 0..1 | CodeableConcept | Filler role Binding: ParticipantRoles (example): Indicates specific responsibility of an individual within the care team, such as "Primary physician", "Team coordinator", "Caregiver", etc. | ||||
performer | Σ | 0..1 | Reference(Practitioner | PractitionerRole | Organization | CareTeam | HealthcareService | Patient | Device | RelatedPerson) | Requested Filler | ||||
reasonCode | Σ | 0..* | CodeableConcept | Coded Reason for request Binding: Condition/Problem/DiagnosisCodes (example): Diagnosis or problem codes justifying the reason for requesting the device. | ||||
reasonReference | Σ | 0..* | Reference(Condition | Observation | DiagnosticReport | DocumentReference) | Linked Reason for request | ||||
insurance | 0..* | Reference(Coverage | ClaimResponse) | Associated insurance coverage | |||||
supportingInfo | 0..* | Reference(Resource) | Additional clinical information | |||||
note | 0..* | Annotation | Notes or comments | |||||
relevantHistory | 0..* | Reference(Provenance) | Request provenance | |||||
Documentation for this format |
Path | Conformance | ValueSet | URI | |||
DeviceRequest.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
DeviceRequest.status | required | RequestStatushttp://hl7.org/fhir/ValueSet/request-status|4.0.1 from the FHIR Standard | ||||
DeviceRequest.intent | required | RequestIntenthttp://hl7.org/fhir/ValueSet/request-intent|4.0.1 from the FHIR Standard | ||||
DeviceRequest.priority | required | RequestPriorityhttp://hl7.org/fhir/ValueSet/request-priority|4.0.1 from the FHIR Standard | ||||
DeviceRequest.code[x] | preferred | FHIRDeviceTypeshttp://hl7.org/fhir/ValueSet/device-kind from the FHIR Standard | ||||
DeviceRequest.parameter.code | example | |||||
DeviceRequest.performerType | example | ParticipantRoleshttp://hl7.org/fhir/ValueSet/participant-role from the FHIR Standard | ||||
DeviceRequest.reasonCode | example | Condition/Problem/DiagnosisCodeshttp://hl7.org/fhir/ValueSet/condition-code from the FHIR Standard |
Id | Grade | Path(s) | Details | Requirements |
dom-2 | error | DeviceRequest | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-3 | error | DeviceRequest | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource : contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty() | |
dom-4 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-5 | error | DeviceRequest | If a resource is contained in another resource, it SHALL NOT have a security label : contained.meta.security.empty() | |
dom-6 | best practice | DeviceRequest | A resource should have narrative for robust management : text.`div`.exists() | |
ele-1 | error | **ALL** elements | All FHIR elements must have a @value or children : hasValue() or (children().count() > id.count()) | |
ext-1 | error | **ALL** extensions | Must have either extensions or value[x], not both : extension.exists() != value.exists() |
This structure is derived from DeviceRequest