QI-Core Implementation Guide: STU 4 (v4.0.0 for FHIR 4.0.1)

QI-Core Implementation Guide - This is the current published version.. See the Directory of published versions

Communication/negation-example

Formats: Narrative, XML, JSON, Turtle

Raw xml


<Communication xmlns="http://hl7.org/fhir">
  <id value="negation-example"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: negation-example</p><p><b>status</b>: not-done</p><p><b>statusReason</b>: Patient has moved away (finding) <span style="background: LightGoldenRodYellow">(Details : {SNOMED CT code '184081006' = 'Patient has moved away', given as 'Patient has moved away (finding)'})</span></p><p><b>category</b>: Alert <span style="background: LightGoldenRodYellow">(Details : {http://acme.org/messagetypes code 'Alert' = 'Alert)</span></p><p><b>medium</b>: written <span style="background: LightGoldenRodYellow">(Details : {http://terminology.hl7.org/CodeSystem/v3-ParticipationMode code 'WRITTEN' = 'written', given as 'written'})</span></p><p><b>subject</b>: <a href="Patient-example.html">Generated Summary: id: example; Medical record number = 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim Chalmers , Peter James Windsor (MAIDEN); ph: (03) 5555 6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate: 1974-12-25; </a></p><p><b>encounter</b>: <a href="Encounter-example.html">Generated Summary: id: example; status: in-progress; <span title="{http://terminology.hl7.org/CodeSystem/v3-ActCode IMP}">inpatient encounter</span>; <span title="Codes: {http://www.ama-assn.org/go/cpt 99223}">Inpatient Hospital Care</span></a></p><p><b>sent</b>: Dec 13, 2014 2:01:10 AM</p><p><b>received</b>: Dec 13, 2014 2:01:11 AM</p><p><b>recipient</b>: <a href="Practitioner-example.html">Generated Summary: id: example; 23; active; Adam Careful </a></p><p><b>sender</b>: <a href="Device-example.html">Generated Summary: id: example; 345675, Serial Number = AMID-342135-8464; status: active; manufacturer: Acme Devices, Inc; lotNumber: 43453424; modelNumber: AB 45-J; <span title="Codes: {http://snomed.info/sct 86184003}">ECG</span>; ph: ext 4352; Author: Practitioner/example; Made: Jun 28, 2015 4:03:32 AM; Annotation: QA Checked</a></p><h3>Payloads</h3><table class="grid"><tr><td>-</td><td><b>Content[x]</b></td></tr><tr><td>*</td><td>Patient 1 has moved away</td></tr></table></div>
  </text>
  <extension
             url="http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-recorded">
    <valueDateTime value="2014-12-12T18:01:10-08:00"/>
  </extension>
  <modifierExtension
                     url="http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-notDone">
    <valueBoolean value="true"/>
  </modifierExtension>
  <status value="not-done"/>
  <statusReason>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="184081006"/>
      <display value="Patient has moved away (finding)"/>
    </coding>
  </statusReason>
  <category>
    <coding>
      <system value="http://acme.org/messagetypes"/>
      <code value="Alert"/>
    </coding>
    <text value="Alert"/>
  </category>
  <medium>
    <coding>
      <system value="http://terminology.hl7.org/CodeSystem/v3-ParticipationMode"/>
      <code value="WRITTEN"/>
      <display value="written"/>
    </coding>
    <text value="written"/>
  </medium>
  <subject>
    <reference value="Patient/example"/>
  </subject>
  <encounter>
    <reference value="Encounter/example"/>
  </encounter>
  <sent value="2014-12-12T18:01:10-08:00"/>
  <received value="2014-12-12T18:01:11-08:00"/>
  <recipient>
    <reference value="Practitioner/example"/>
  </recipient>
  <sender>
    <reference value="Device/example"/>
  </sender>
  <payload>
    <contentString value="Patient 1 has moved away"/>
  </payload>
</Communication>