QI-Core Implementation Guide: STU 4 (v4.0.0 for FHIR 4.0.1)

QI-Core Implementation Guide - This is the current published version.. See the Directory of published versions

Communication/example

Formats: Narrative, XML, JSON, Turtle

Raw xml


<Communication xmlns="http://hl7.org/fhir">
  <id value="example"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-communication"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>meta</b>: </p><p><b>partOf</b>: Serum Potassium Observation</p><p><b>status</b>: not-done</p><p><b>statusReason</b>: Recipient Unavailable <span style="background: LightGoldenRodYellow">(Details : {http://terminology.hl7.org/CodeSystem/communication-not-done-reason code 'recipient-unavailable' = 'Recipient Unavailable)</span></p><p><b>category</b>: Alert <span style="background: LightGoldenRodYellow">(Details : {http://acme.org/messagetypes code 'Alert' = 'Alert)</span></p><p><b>medium</b>: written <span style="background: LightGoldenRodYellow">(Details : {http://terminology.hl7.org/CodeSystem/v3-ParticipationMode code 'WRITTEN' = 'written', given as 'written'})</span></p><p><b>subject</b>: <a href="Patient-example.html">Generated Summary: id: example; Medical record number = 12345 (USUAL); active; Peter James Chalmers (OFFICIAL), Jim Chalmers , Peter James Windsor (MAIDEN); ph: (03) 5555 6473(WORK), ph: (03) 3410 5613(MOBILE), ph: (03) 5555 8834(OLD); gender: male; birthDate: 1974-12-25; </a></p><p><b>topic</b>: Hyperkalemia <span style="background: LightGoldenRodYellow">(Details )</span></p><p><b>encounter</b>: <a href="Encounter-example.html">Generated Summary: id: example; status: in-progress; <span title="{http://terminology.hl7.org/CodeSystem/v3-ActCode IMP}">inpatient encounter</span>; <span title="Codes: {http://www.ama-assn.org/go/cpt 99223}">Inpatient Hospital Care</span></a></p><p><b>sent</b>: Dec 13, 2014 2:01:10 AM</p><p><b>received</b>: Dec 13, 2014 2:01:11 AM</p><p><b>recipient</b>: <a href="Practitioner-example.html">Generated Summary: id: example; 23; active; Adam Careful </a></p><p><b>sender</b>: <a href="Device-example.html">Generated Summary: id: example; 345675, Serial Number = AMID-342135-8464; status: active; manufacturer: Acme Devices, Inc; lotNumber: 43453424; modelNumber: AB 45-J; <span title="Codes: {http://snomed.info/sct 86184003}">ECG</span>; ph: ext 4352; Author: Practitioner/example; Made: Jun 28, 2015 4:03:32 AM; Annotation: QA Checked</a></p><blockquote><p><b>payload</b></p><p><b>content</b>: Patient 1 has a very high serum potassium value (7.2 mmol/L on 2014-Dec-12 at 5:55 pm)</p></blockquote><blockquote><p><b>payload</b></p><p><b>content</b>: Serum Potassium Observation</p></blockquote></div>
  </text>
<!--  NOTE: This identifier is based on an example in the base spec and does not make sense in this context  -->
<!--  <identifier>
    <type>
        <text value="Paging System"/>
    </type>
    <system value="urn:oid:1.3.4.5.6.7"/>
    <value value="2345678901"/>
  </identifier>  -->
  <partOf>
    <display value="Serum Potassium Observation"/>
  </partOf>
  <status value="not-done"/>
  <statusReason>
    <coding>
      <system
              value="http://terminology.hl7.org/CodeSystem/communication-not-done-reason"/>
      <code value="recipient-unavailable"/>
    </coding>
  </statusReason>
  <category>
    <coding>
      <system value="http://acme.org/messagetypes"/>
      <code value="Alert"/>
    </coding>
    <text value="Alert"/>
  </category>
  <medium>
    <coding>
      <system value="http://terminology.hl7.org/CodeSystem/v3-ParticipationMode"/>
      <code value="WRITTEN"/>
      <display value="written"/>
    </coding>
    <text value="written"/>
  </medium>
  <subject>
    <reference value="Patient/example"/>
  </subject>
  <topic>
    <text value="Hyperkalemia"/>
  </topic>
  <encounter>
    <reference value="Encounter/example"/>
  </encounter>
  <sent value="2014-12-12T18:01:10-08:00"/>
  <received value="2014-12-12T18:01:11-08:00"/>
  <recipient>
    <reference value="Practitioner/example"/>
  </recipient>
  <sender>
    <reference value="Device/example"/>
  </sender>
  <payload>
    <contentString
                   value="Patient 1 has a very high serum potassium value (7.2 mmol/L on 2014-Dec-12 at 5:55 pm)"/>
  </payload>
  <payload>
  <!--   Reference to the lab result    -->
    <contentReference>
      <display value="Serum Potassium Observation"/>
    </contentReference>
  </payload>
</Communication>