This page is part of the Quality Improvement Core Framework (v3.1.0: STU 3) based on FHIR R3. The current version which supercedes this version is 4.1.1. For a full list of available versions, see the Directory of published versions
General Device Example |
The official URL for this profile is:
http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-device
Profile of Device for decision support/quality metrics. Defines the core set of elements and extensions for quality rule and measure authors.
This profile builds on US Core Device Profile.
This profile was published on Wed Aug 22 00:00:00 AEST 2018 as a draft by Health Level Seven, Inc. - CQI WG.
Description of Profiles, Differentials, and Snapshots.
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | |||
udi | S | 1..1 | BackboneElement | |
deviceIdentifier | 0..1 | string | ||
carrierHRF | 0..1 | string | ||
carrierAIDC | 0..1 | base64Binary | ||
status | S | 0..1 | code | |
type | S | 1..1 | CodeableConcept | Binding: FHIR Device Types (preferred) |
patient | S | 1..1 | Reference(QICore-Patient) | |
owner | 0..1 | Reference(QICore-Organization) | ||
location | S | 0..1 | Reference(QICore-Location) | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | I | 0..* | US Core Implanted Device Profile | |
id | Σ | 0..1 | id | Logical id of this artifact |
meta | Σ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: Common Languages (extensible) | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | 0..* | Identifier | Instance identifier | |
udi | SΣI | 1..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored |
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI |
name | Σ | 0..1 | string | Device Name as appears on UDI label |
jurisdiction | 0..1 | uri | Regional UDI authority | |
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String |
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
issuer | 0..1 | uri | UDI Issuing Organization | |
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required) | |
status | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
type | S | 1..1 | CodeableConcept | What kind of device this is Binding: FHIR Device Types (preferred) |
lotNumber | 0..1 | string | Lot number of manufacture | |
manufacturer | 0..1 | string | Name of device manufacturer | |
manufactureDate | 0..1 | dateTime | Date when the device was made | |
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
model | 0..1 | string | Model id assigned by the manufacturer | |
version | 0..1 | string | Version number (i.e. software) | |
patient | S | 1..1 | Reference(QICore-Patient) | Patient to whom Device is affixed |
owner | 0..1 | Reference(QICore-Organization) | Organization responsible for device | |
contact | 0..* | ContactPoint | Details for human/organization for support | |
location | S | 0..1 | Reference(QICore-Location) | Where the resource is found |
url | 0..1 | uri | Network address to contact device | |
note | 0..* | Annotation | Device notes and comments | |
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device Binding: DeviceSafety (example) |
Documentation for this format |
Differential View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | 0..* | |||
udi | S | 1..1 | BackboneElement | |
deviceIdentifier | 0..1 | string | ||
carrierHRF | 0..1 | string | ||
carrierAIDC | 0..1 | base64Binary | ||
status | S | 0..1 | code | |
type | S | 1..1 | CodeableConcept | Binding: FHIR Device Types (preferred) |
patient | S | 1..1 | Reference(QICore-Patient) | |
owner | 0..1 | Reference(QICore-Organization) | ||
location | S | 0..1 | Reference(QICore-Location) | |
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | I | 0..* | US Core Implanted Device Profile | |
id | Σ | 0..1 | id | Logical id of this artifact |
meta | Σ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: Common Languages (extensible) | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | 0..* | Identifier | Instance identifier | |
udi | SΣI | 1..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored |
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI |
name | Σ | 0..1 | string | Device Name as appears on UDI label |
jurisdiction | 0..1 | uri | Regional UDI authority | |
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String |
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
issuer | 0..1 | uri | UDI Issuing Organization | |
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required) | |
status | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
type | S | 1..1 | CodeableConcept | What kind of device this is Binding: FHIR Device Types (preferred) |
lotNumber | 0..1 | string | Lot number of manufacture | |
manufacturer | 0..1 | string | Name of device manufacturer | |
manufactureDate | 0..1 | dateTime | Date when the device was made | |
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
model | 0..1 | string | Model id assigned by the manufacturer | |
version | 0..1 | string | Version number (i.e. software) | |
patient | S | 1..1 | Reference(QICore-Patient) | Patient to whom Device is affixed |
owner | 0..1 | Reference(QICore-Organization) | Organization responsible for device | |
contact | 0..* | ContactPoint | Details for human/organization for support | |
location | S | 0..1 | Reference(QICore-Location) | Where the resource is found |
url | 0..1 | uri | Network address to contact device | |
note | 0..* | Annotation | Device notes and comments | |
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device Binding: DeviceSafety (example) |
Documentation for this format |
Path | Name | Conformance | ValueSet |
Device.language | Common Languages | extensible | Common Languages |
Device.udi.entryType | UDIEntryType | required | UDIEntryType |
Device.status | FHIRDeviceStatus | required | FHIRDeviceStatus |
Device.type | FHIR Device Types | preferred | FHIR Device Types |
Device.safety | DeviceSafety | example | DeviceSafety |
Id | Path | Details | Requirements |
dom-2 | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-1 | Device | If the resource is contained in another resource, it SHALL NOT contain any narrative : contained.text.empty() | |
dom-4 | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-3 | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource : contained.where(('#'+id in %resource.descendants().reference).not()).empty() | |
ele-1 | Device.udi | All FHIR elements must have a @value or children : hasValue() | (children().count() > id.count()) |