This page is part of the Quality Improvement Core Framework (v2.1.0: STU 3 Ballot 1) based on FHIR R3. The current version which supercedes this version is 4.1.1. For a full list of available versions, see the Directory of published versions
General Device Example |
The official URL for this profile is:
http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-device
This profile builds on US Core Implanted Device Profile.
This profile was published on Mon Aug 21 16:00:00 AEST 2017 as a draft by Health Level Seven International (Clinical Quality Information - QICore).
Description of Profiles, Differentials, and Snapshots.
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | I | 0..* | Item used in healthcare | |
id | Σ | 0..1 | id | Logical id of this artifact |
meta | Σ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: Common Languages (extensible) | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | 0..* | Identifier | Instance identifier | |
udi | SΣI | 1..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored |
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI |
name | Σ | 0..1 | string | Device Name as appears on UDI label |
jurisdiction | 0..1 | uri | Regional UDI authority | |
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String |
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
issuer | 0..1 | uri | UDI Issuing Organization | |
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required) | |
status | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
type | S | 1..1 | CodeableConcept | What kind of device this is Binding: FHIR Device Types (preferred) |
lotNumber | 0..1 | string | Lot number of manufacture | |
manufacturer | 0..1 | string | Name of device manufacturer | |
manufactureDate | 0..1 | dateTime | Date when the device was made | |
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
model | 0..1 | string | Model id assigned by the manufacturer | |
version | 0..1 | string | Version number (i.e. software) | |
patient | S | 1..1 | Reference(QICore-Patient) | Patient to whom Device is affixed |
owner | 0..1 | Reference(QICore-Organization) | Organization responsible for device | |
contact | 0..* | ContactPoint | Details for human/organization for support | |
location | S | 0..1 | Reference(QICore-Location) | Where the resource is found |
url | 0..1 | uri | Network address to contact device | |
note | 0..* | Annotation | Device notes and comments | |
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device Binding: DeviceSafety (example) |
Documentation for this format |
Differential View
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Device | I | 0..* | Item used in healthcare | |
id | Σ | 0..1 | id | Logical id of this artifact |
meta | Σ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: Common Languages (extensible) | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | 0..* | Identifier | Instance identifier | |
udi | SΣI | 1..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored |
deviceIdentifier | Σ | 0..1 | string | Mandatory fixed portion of UDI |
name | Σ | 0..1 | string | Device Name as appears on UDI label |
jurisdiction | 0..1 | uri | Regional UDI authority | |
carrierHRF | Σ | 0..1 | string | UDI Human Readable Barcode String |
carrierAIDC | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
issuer | 0..1 | uri | UDI Issuing Organization | |
entryType | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required) | |
status | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
type | S | 1..1 | CodeableConcept | What kind of device this is Binding: FHIR Device Types (preferred) |
lotNumber | 0..1 | string | Lot number of manufacture | |
manufacturer | 0..1 | string | Name of device manufacturer | |
manufactureDate | 0..1 | dateTime | Date when the device was made | |
expirationDate | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
model | 0..1 | string | Model id assigned by the manufacturer | |
version | 0..1 | string | Version number (i.e. software) | |
patient | S | 1..1 | Reference(QICore-Patient) | Patient to whom Device is affixed |
owner | 0..1 | Reference(QICore-Organization) | Organization responsible for device | |
contact | 0..* | ContactPoint | Details for human/organization for support | |
location | S | 0..1 | Reference(QICore-Location) | Where the resource is found |
url | 0..1 | uri | Network address to contact device | |
note | 0..* | Annotation | Device notes and comments | |
safety | Σ | 0..* | CodeableConcept | Safety Characteristics of Device Binding: DeviceSafety (example) |
Documentation for this format |
Path | Name | Conformance | ValueSet |
Device.language | Common Languages | extensible | Common Languages |
Device.udi.entryType | UDIEntryType | required | UDIEntryType |
Device.status | FHIRDeviceStatus | required | FHIRDeviceStatus |
Device.type | FHIR Device Types | preferred | FHIR Device Types |
Device.safety | DeviceSafety | example | DeviceSafety |
Id | Path | Details | Requirements |
dom-2 | Device | If the resource is contained in another resource, it SHALL NOT contain nested Resources : contained.contained.empty() | |
dom-1 | Device | If the resource is contained in another resource, it SHALL NOT contain any narrative : contained.text.empty() | |
dom-4 | Device | If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated : contained.meta.versionId.empty() and contained.meta.lastUpdated.empty() | |
dom-3 | Device | If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource : contained.where(('#'+id in %resource.descendants().reference).not()).empty() | |
ele-1 | Device.udi | All FHIR elements must have a @value or children : hasValue() | (children().count() > id.count()) |