Pharmaceutical Quality - Chemistry, Manufacturing and Controls (PQ-CMC) Submissions to FDA
1.0.0 - STU1 United States of America flag

This page is part of the Pharmaceutical Quality - Chemistry, Manufacturing and Controls (PQ-CMC) Submissions to FDA (v1.0.0: STU1) based on FHIR (HL7® FHIR® Standard) v5.0.0. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

Data Type Profile: Analytical Instrument Data ( Abstract )

Official URL: http://hl7.org/fhir/us/pq-cmc-fda/StructureDefinition/pqcmc-analytical-intstrument-data Version: 1.0.0
Active as of 2024-12-11 Computable Name: AnalyticalInstrumentData
Other Identifiers: OID:2.16.840.1.113883.4.642.40.36.42.55

Any attached file that contains analytical instrument data

Usage:

  • This DataType Constraint is not used by any profiles in this Implementation Guide

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from PqcmcAttachment

NameFlagsCard.TypeDescription & Constraintsdoco
.. Attachment 0..* PqcmcAttachment This is an abstractprofile.
Content in a format defined elsewhere
... contentType 1..1 code Mime type of the content, with charset etc.
Binding: Analytical Instrument Data File Types (required)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Attachment.contentTyperequiredPqcmcAnalyticalInstrumentDataTypes
http://hl7.org/fhir/us/pq-cmc-fda/ValueSet/pqcmc-analytical-instrument-data-types
from this IG
NameFlagsCard.TypeDescription & Constraintsdoco
.. Attachment C 0..* PqcmcAttachment This is an abstractprofile.
Content in a format defined elsewhere
att-1: If the Attachment has data, it SHALL have a contentType
ele-1: All FHIR elements must have a @value or children
... contentType SΣC 1..1 code Mime type of the content, with charset etc.
Binding: Analytical Instrument Data File Types (required)
ele-1: All FHIR elements must have a @value or children
Example General: text/plain; charset=UTF-8, image/png
... data SC 1..1 base64Binary Data inline, base64ed
ele-1: All FHIR elements must have a @value or children
... title SΣ 1..1 string Document file name including the file extension
ele-1: All FHIR elements must have a @value or children
Example General: Official Corporate Logo

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Attachment.contentTyperequiredPqcmcAnalyticalInstrumentDataTypes
http://hl7.org/fhir/us/pq-cmc-fda/ValueSet/pqcmc-analytical-instrument-data-types
from this IG

Constraints

IdGradePath(s)DetailsRequirements
att-1errorAttachmentIf the Attachment has data, it SHALL have a contentType
: data.empty() or contentType.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
NameFlagsCard.TypeDescription & Constraintsdoco
.. Attachment C 0..* PqcmcAttachment This is an abstractprofile.
Content in a format defined elsewhere
att-1: If the Attachment has data, it SHALL have a contentType
... id 0..1 id Unique id for inter-element referencing
... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
... contentType SΣC 1..1 code Mime type of the content, with charset etc.
Binding: Analytical Instrument Data File Types (required)
Example General: text/plain; charset=UTF-8, image/png
... data SC 1..1 base64Binary Data inline, base64ed
... url Σ 0..1 url Uri where the data can be found
Example General: http://www.acme.com/logo-small.png
... size Σ 0..1 integer64 Number of bytes of content (if url provided)
... hash Σ 0..1 base64Binary Hash of the data (sha-1, base64ed)
... title SΣ 1..1 string Document file name including the file extension
Example General: Official Corporate Logo
... creation Σ 0..1 dateTime Date attachment was first created
... height 0..1 positiveInt Height of the image in pixels (photo/video)
... width 0..1 positiveInt Width of the image in pixels (photo/video)
... frames 0..1 positiveInt Number of frames if > 1 (photo)
... duration 0..1 decimal Length in seconds (audio / video)
... pages 0..1 positiveInt Number of printed pages

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Attachment.contentTyperequiredPqcmcAnalyticalInstrumentDataTypes
http://hl7.org/fhir/us/pq-cmc-fda/ValueSet/pqcmc-analytical-instrument-data-types
from this IG
Attachment.languagerequiredAllLanguages
http://hl7.org/fhir/ValueSet/all-languages|5.0.0
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
att-1errorAttachmentIf the Attachment has data, it SHALL have a contentType
: data.empty() or contentType.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

This structure is derived from PqcmcAttachment

Summary

Differential View

This structure is derived from PqcmcAttachment

NameFlagsCard.TypeDescription & Constraintsdoco
.. Attachment 0..* PqcmcAttachment This is an abstractprofile.
Content in a format defined elsewhere
... contentType 1..1 code Mime type of the content, with charset etc.
Binding: Analytical Instrument Data File Types (required)

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSetURI
Attachment.contentTyperequiredPqcmcAnalyticalInstrumentDataTypes
http://hl7.org/fhir/us/pq-cmc-fda/ValueSet/pqcmc-analytical-instrument-data-types
from this IG

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Attachment C 0..* PqcmcAttachment This is an abstractprofile.
Content in a format defined elsewhere
att-1: If the Attachment has data, it SHALL have a contentType
ele-1: All FHIR elements must have a @value or children
... contentType SΣC 1..1 code Mime type of the content, with charset etc.
Binding: Analytical Instrument Data File Types (required)
ele-1: All FHIR elements must have a @value or children
Example General: text/plain; charset=UTF-8, image/png
... data SC 1..1 base64Binary Data inline, base64ed
ele-1: All FHIR elements must have a @value or children
... title SΣ 1..1 string Document file name including the file extension
ele-1: All FHIR elements must have a @value or children
Example General: Official Corporate Logo

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Attachment.contentTyperequiredPqcmcAnalyticalInstrumentDataTypes
http://hl7.org/fhir/us/pq-cmc-fda/ValueSet/pqcmc-analytical-instrument-data-types
from this IG

Constraints

IdGradePath(s)DetailsRequirements
att-1errorAttachmentIf the Attachment has data, it SHALL have a contentType
: data.empty() or contentType.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Attachment C 0..* PqcmcAttachment This is an abstractprofile.
Content in a format defined elsewhere
att-1: If the Attachment has data, it SHALL have a contentType
... id 0..1 id Unique id for inter-element referencing
... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
... contentType SΣC 1..1 code Mime type of the content, with charset etc.
Binding: Analytical Instrument Data File Types (required)
Example General: text/plain; charset=UTF-8, image/png
... data SC 1..1 base64Binary Data inline, base64ed
... url Σ 0..1 url Uri where the data can be found
Example General: http://www.acme.com/logo-small.png
... size Σ 0..1 integer64 Number of bytes of content (if url provided)
... hash Σ 0..1 base64Binary Hash of the data (sha-1, base64ed)
... title SΣ 1..1 string Document file name including the file extension
Example General: Official Corporate Logo
... creation Σ 0..1 dateTime Date attachment was first created
... height 0..1 positiveInt Height of the image in pixels (photo/video)
... width 0..1 positiveInt Width of the image in pixels (photo/video)
... frames 0..1 positiveInt Number of frames if > 1 (photo)
... duration 0..1 decimal Length in seconds (audio / video)
... pages 0..1 positiveInt Number of printed pages

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Attachment.contentTyperequiredPqcmcAnalyticalInstrumentDataTypes
http://hl7.org/fhir/us/pq-cmc-fda/ValueSet/pqcmc-analytical-instrument-data-types
from this IG
Attachment.languagerequiredAllLanguages
http://hl7.org/fhir/ValueSet/all-languages|5.0.0
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
att-1errorAttachmentIf the Attachment has data, it SHALL have a contentType
: data.empty() or contentType.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

This structure is derived from PqcmcAttachment

Summary

 