minimal Common Oncology Data Elements (mCODE) Implementation Guide
4.0.0-ballot - STU4 Ballot United States of America flag

This page is part of the HL7 FHIR Implementation Guide: minimal Common Oncology Data Elements (mCODE) Release 1 - US Realm | STU1 (v4.0.0-ballot: STU4 Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 3.0.0. For a full list of available versions, see the Directory of published versions

Resource Profile: ECOG Performance Status Profile

Official URL: http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-ecog-performance-status Version: 4.0.0-ballot
Active as of 2024-04-10 Maturity Level: 4 Computable Name: ECOGPerformanceStatus
Other Identifiers: OID:2.16.840.1.113883.4.642.40.15.42.17

The Eastern Cooperative Oncology Group (ECOG) Performance Status represents the patient’s functional status and is used to determine their ability to tolerate therapies in serious illness, specifically for chemotherapy. (Definition from: LOINC)

Conformance

Observation resources associated with an in-scope patient with Observation.code LOINC 89247-1 SHALL conform to this profile. Beyond this requirement, a producer of resources SHOULD ensure that any resource instance associated with an in-scope patient that would reasonably be expected to conform to this profile SHOULD be published in this form.

Usage:

Changes since version true:

  • No changes
  • Formal Views of Profile Content

    Description of Profiles, Differentials, Snapshots and how the different presentations work.

    This structure is derived from USCoreObservationClinicalTestResultProfile

    NameFlagsCard.TypeDescription & Constraintsdoco
    .. Observation 0..* USCoreObservationClinicalTestResultProfile Measurements and simple assertions
    ... basedOn 0..* Reference(ServiceRequest | CarePlan) Fulfills plan, proposal or order
    ... partOf 0..* Reference(Procedure) Part of referenced event
    ... code 1..1 CodeableConcept Clinical Test Name
    Required Pattern: At least the following
    .... coding 1..* Coding Code defined by a terminology system
    Fixed Value: (complex)
    ..... system 1..1 uri Identity of the terminology system
    Fixed Value: http://loinc.org
    ..... code 1..1 code Symbol in syntax defined by the system
    Fixed Value: 89247-1
    ... effective[x] 0..1 Clinically relevant time/time-period for observation
    .... effectiveDateTime dateTime
    .... effectivePeriod Period
    ... value[x] 0..1 integer Result Value
    ... interpretation S 0..* CodeableConcept High, low, normal, etc.
    Binding: LOINC Answer List LL529-9 (required)
    ... bodySite 0..1 CodeableConcept Not used in this profile
    ... specimen 0..1 Reference(Specimen) Not used in this profile
    ... device 0..1 Reference(Device | DeviceMetric) Not used in this profile
    ... hasMember 0..* Reference(Observation | QuestionnaireResponse | MolecularSequence) Not used in this profile
    ... component 0..* BackboneElement Not used in this profile

    doco Documentation for this format

    Terminology Bindings (Differential)

    PathConformanceValueSetURI
    Observation.interpretationrequiredLOINC LL529-9
    http://loinc.org/vs/LL529-9
    NameFlagsCard.TypeDescription & Constraintsdoco
    .. Observation C 0..* USCoreObservationClinicalTestResultProfile Measurements and simple assertions
    obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
    obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
    us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present
    ... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
    ... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
    ... basedOn Σ 0..* Reference(ServiceRequest | CarePlan) Fulfills plan, proposal or order
    ... status ?!SΣ 1..1 code registered | preliminary | final | amended +
    Binding: ObservationStatus (required): Codes providing the status of an observation.

    ... Slices for category S 1..* CodeableConcept Classification of type of observation
    Slice: Unordered, Open by pattern:$this
    Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


    .... category:clinical-test S 1..1 CodeableConcept Classification of type of observation
    Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.



    Required Pattern: At least the following
    ..... coding 1..* Coding Code defined by a terminology system
    Fixed Value: (complex)
    ...... system 1..1 uri Identity of the terminology system
    Fixed Value: http://hl7.org/fhir/us/core/CodeSystem/us-core-observation-category
    ...... code 1..1 code Symbol in syntax defined by the system
    Fixed Value: clinical-test
    ... code SΣ 1..1 CodeableConcept Clinical Test Name
    Binding: US Core Clinical Test Codes (extensible)
    Required Pattern: At least the following
    .... coding 1..* Coding Code defined by a terminology system
    Fixed Value: (complex)
    ..... system 1..1 uri Identity of the terminology system
    Fixed Value: http://loinc.org
    ..... code 1..1 code Symbol in syntax defined by the system
    Fixed Value: 89247-1
    ... subject SΣ 1..1 Reference(Cancer Patient Profile) Who and/or what the observation is about
    ... effective[x] SΣC 0..1 Clinically relevant time/time-period for observation
    us-core-1: Datetime must be at least to day.
    .... effectiveDateTime dateTime
    ... value[x] SΣC 0..1 integer Result Value
    us-core-3: SHALL use UCUM for coded quantity units.
    ... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
    Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

    ... interpretation S 0..* CodeableConcept High, low, normal, etc.
    Binding: LOINC Answer List LL529-9 (required)
    ... bodySite 0..1 CodeableConcept Not used in this profile
    Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

    ... specimen 0..1 Reference(Specimen) Not used in this profile
    ... device 0..1 Reference(Device | DeviceMetric) Not used in this profile
    ... hasMember Σ 0..* Reference(Observation | QuestionnaireResponse | MolecularSequence) Not used in this profile
    ... component Σ 0..* BackboneElement Not used in this profile
    .... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
    .... code Σ 1..1 CodeableConcept Type of component observation (code / type)
    Binding: LOINCCodes (example): Codes identifying names of simple observations.


    doco Documentation for this format

    Terminology Bindings

    PathConformanceValueSet / CodeURI
    Observation.statusrequiredObservationStatus
    http://hl7.org/fhir/ValueSet/observation-status|4.0.1
    from the FHIR Standard
    Observation.categorypreferredObservationCategoryCodes
    http://hl7.org/fhir/ValueSet/observation-category
    from the FHIR Standard
    Observation.category:clinical-testpreferredPattern: clinical-test
    http://hl7.org/fhir/ValueSet/observation-category
    from the FHIR Standard
    Observation.codeextensiblePattern: LOINC code 89247-1
    http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-test-codes
    Observation.dataAbsentReasonextensibleDataAbsentReason
    http://hl7.org/fhir/ValueSet/data-absent-reason
    from the FHIR Standard
    Observation.interpretationrequiredLOINC LL529-9
    http://loinc.org/vs/LL529-9
    Observation.bodySiteexampleSNOMEDCTBodyStructures
    http://hl7.org/fhir/ValueSet/body-site
    from the FHIR Standard
    Observation.component.codeexampleLOINCCodes (a valid code from LOINC)
    http://hl7.org/fhir/ValueSet/observation-codes
    from the FHIR Standard
    NameFlagsCard.TypeDescription & Constraintsdoco
    .. Observation C 0..* USCoreObservationClinicalTestResultProfile Measurements and simple assertions
    obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
    obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
    us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present
    ... id Σ 0..1 id Logical id of this artifact
    ... meta Σ 0..1 Meta Metadata about the resource
    ... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
    ... language 0..1 code Language of the resource content
    Binding: CommonLanguages (preferred): A human language.

    Additional BindingsPurpose
    AllLanguages Max Binding
    ... text 0..1 Narrative Text summary of the resource, for human interpretation
    ... contained 0..* Resource Contained, inline Resources
    ... extension 0..* Extension Additional content defined by implementations
    ... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
    ... identifier Σ 0..* Identifier Business Identifier for observation
    ... basedOn Σ 0..* Reference(ServiceRequest | CarePlan) Fulfills plan, proposal or order
    ... partOf Σ 0..* Reference(Procedure) Part of referenced event
    ... status ?!SΣ 1..1 code registered | preliminary | final | amended +
    Binding: ObservationStatus (required): Codes providing the status of an observation.

    ... Slices for category S 1..* CodeableConcept Classification of type of observation
    Slice: Unordered, Open by pattern:$this
    Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


    .... category:clinical-test S 1..1 CodeableConcept Classification of type of observation
    Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.



    Required Pattern: At least the following
    ..... id 0..1 string Unique id for inter-element referencing
    ..... extension 0..* Extension Additional content defined by implementations
    ..... coding 1..* Coding Code defined by a terminology system
    Fixed Value: (complex)
    ...... id 0..1 string Unique id for inter-element referencing
    ...... extension 0..* Extension Additional content defined by implementations
    ...... system 1..1 uri Identity of the terminology system
    Fixed Value: http://hl7.org/fhir/us/core/CodeSystem/us-core-observation-category
    ...... version 0..1 string Version of the system - if relevant
    ...... code 1..1 code Symbol in syntax defined by the system
    Fixed Value: clinical-test
    ...... display 0..1 string Representation defined by the system
    ...... userSelected 0..1 boolean If this coding was chosen directly by the user
    ..... text 0..1 string Plain text representation of the concept
    ... code SΣ 1..1 CodeableConcept Clinical Test Name
    Binding: US Core Clinical Test Codes (extensible)
    Required Pattern: At least the following
    .... id 0..1 string Unique id for inter-element referencing
    .... extension 0..* Extension Additional content defined by implementations
    .... coding 1..* Coding Code defined by a terminology system
    Fixed Value: (complex)
    ..... id 0..1 string Unique id for inter-element referencing
    ..... extension 0..* Extension Additional content defined by implementations
    ..... system 1..1 uri Identity of the terminology system
    Fixed Value: http://loinc.org
    ..... version 0..1 string Version of the system - if relevant
    ..... code 1..1 code Symbol in syntax defined by the system
    Fixed Value: 89247-1
    ..... display 0..1 string Representation defined by the system
    ..... userSelected 0..1 boolean If this coding was chosen directly by the user
    .... text 0..1 string Plain text representation of the concept
    ... subject SΣ 1..1 Reference(Cancer Patient Profile) Who and/or what the observation is about
    ... focus Σ 0..* Reference(Resource) What the observation is about, when it is not about the subject of record
    ... encounter Σ 0..1 Reference(Encounter) Healthcare event during which this observation is made
    ... effective[x] SΣC 0..1 Clinically relevant time/time-period for observation
    us-core-1: Datetime must be at least to day.
    .... effectiveDateTime dateTime S
    .... effectivePeriod Period
    ... issued Σ 0..1 instant Date/Time this version was made available
    ... performer Σ 0..* Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Who is responsible for the observation
    ... value[x] SΣC 0..1 integer Result Value
    us-core-3: SHALL use UCUM for coded quantity units.
    ... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
    Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

    ... interpretation S 0..* CodeableConcept High, low, normal, etc.
    Binding: LOINC Answer List LL529-9 (required)
    ... note 0..* Annotation Comments about the observation
    ... bodySite 0..1 CodeableConcept Not used in this profile
    Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

    ... method 0..1 CodeableConcept How it was done
    Binding: ObservationMethods (example): Methods for simple observations.

    ... specimen 0..1 Reference(Specimen) Not used in this profile
    ... device 0..1 Reference(Device | DeviceMetric) Not used in this profile
    ... referenceRange C 0..* BackboneElement Provides guide for interpretation
    obs-3: Must have at least a low or a high or text
    .... id 0..1 string Unique id for inter-element referencing
    .... extension 0..* Extension Additional content defined by implementations
    .... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
    .... low C 0..1 SimpleQuantity Low Range, if relevant
    .... high C 0..1 SimpleQuantity High Range, if relevant
    .... type 0..1 CodeableConcept Reference range qualifier
    Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

    .... appliesTo 0..* CodeableConcept Reference range population
    Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


    .... age 0..1 Range Applicable age range, if relevant
    .... text 0..1 string Text based reference range in an observation
    ... hasMember Σ 0..* Reference(Observation | QuestionnaireResponse | MolecularSequence) Not used in this profile
    ... derivedFrom Σ 0..* Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) Related measurements the observation is made from
    ... component Σ 0..* BackboneElement Not used in this profile
    .... id 0..1 string Unique id for inter-element referencing
    .... extension 0..* Extension Additional content defined by implementations
    .... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
    .... code Σ 1..1 CodeableConcept Type of component observation (code / type)
    Binding: LOINCCodes (example): Codes identifying names of simple observations.

    .... value[x] Σ 0..1 Actual component result
    ..... valueQuantity Quantity
    ..... valueCodeableConcept CodeableConcept
    ..... valueString string
    ..... valueBoolean boolean
    ..... valueInteger integer
    ..... valueRange Range
    ..... valueRatio Ratio
    ..... valueSampledData SampledData
    ..... valueTime time
    ..... valueDateTime dateTime
    ..... valuePeriod Period
    .... dataAbsentReason C 0..1 CodeableConcept Why the component result is missing
    Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

    .... interpretation 0..* CodeableConcept High, low, normal, etc.
    Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


    .... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result

    doco Documentation for this format

    Terminology Bindings

    PathConformanceValueSet / CodeURI
    Observation.languagepreferredCommonLanguages
    Additional Bindings Purpose
    AllLanguages Max Binding
    http://hl7.org/fhir/ValueSet/languages
    from the FHIR Standard
    Observation.statusrequiredObservationStatus
    http://hl7.org/fhir/ValueSet/observation-status|4.0.1
    from the FHIR Standard
    Observation.categorypreferredObservationCategoryCodes
    http://hl7.org/fhir/ValueSet/observation-category
    from the FHIR Standard
    Observation.category:clinical-testpreferredPattern: clinical-test
    http://hl7.org/fhir/ValueSet/observation-category
    from the FHIR Standard
    Observation.codeextensiblePattern: LOINC code 89247-1
    http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-test-codes
    Observation.dataAbsentReasonextensibleDataAbsentReason
    http://hl7.org/fhir/ValueSet/data-absent-reason
    from the FHIR Standard
    Observation.interpretationrequiredLOINC LL529-9
    http://loinc.org/vs/LL529-9
    Observation.bodySiteexampleSNOMEDCTBodyStructures
    http://hl7.org/fhir/ValueSet/body-site
    from the FHIR Standard
    Observation.methodexampleObservationMethods
    http://hl7.org/fhir/ValueSet/observation-methods
    from the FHIR Standard
    Observation.referenceRange.typepreferredObservationReferenceRangeMeaningCodes
    http://hl7.org/fhir/ValueSet/referencerange-meaning
    from the FHIR Standard
    Observation.referenceRange.appliesToexampleObservationReferenceRangeAppliesToCodes
    http://hl7.org/fhir/ValueSet/referencerange-appliesto
    from the FHIR Standard
    Observation.component.codeexampleLOINCCodes (a valid code from LOINC)
    http://hl7.org/fhir/ValueSet/observation-codes
    from the FHIR Standard
    Observation.component.dataAbsentReasonextensibleDataAbsentReason
    http://hl7.org/fhir/ValueSet/data-absent-reason
    from the FHIR Standard
    Observation.component.interpretationextensibleObservationInterpretationCodes
    http://hl7.org/fhir/ValueSet/observation-interpretation
    from the FHIR Standard

    This structure is derived from USCoreObservationClinicalTestResultProfile

    Summary

    Must-Support: 1 element

    Structures

    This structure refers to these other structures:

    Maturity: 4

    Differential View

    This structure is derived from USCoreObservationClinicalTestResultProfile

    NameFlagsCard.TypeDescription & Constraintsdoco
    .. Observation 0..* USCoreObservationClinicalTestResultProfile Measurements and simple assertions
    ... basedOn 0..* Reference(ServiceRequest | CarePlan) Fulfills plan, proposal or order
    ... partOf 0..* Reference(Procedure) Part of referenced event
    ... code 1..1 CodeableConcept Clinical Test Name
    Required Pattern: At least the following
    .... coding 1..* Coding Code defined by a terminology system
    Fixed Value: (complex)
    ..... system 1..1 uri Identity of the terminology system
    Fixed Value: http://loinc.org
    ..... code 1..1 code Symbol in syntax defined by the system
    Fixed Value: 89247-1
    ... effective[x] 0..1 Clinically relevant time/time-period for observation
    .... effectiveDateTime dateTime
    .... effectivePeriod Period
    ... value[x] 0..1 integer Result Value
    ... interpretation S 0..* CodeableConcept High, low, normal, etc.
    Binding: LOINC Answer List LL529-9 (required)
    ... bodySite 0..1 CodeableConcept Not used in this profile
    ... specimen 0..1 Reference(Specimen) Not used in this profile
    ... device 0..1 Reference(Device | DeviceMetric) Not used in this profile
    ... hasMember 0..* Reference(Observation | QuestionnaireResponse | MolecularSequence) Not used in this profile
    ... component 0..* BackboneElement Not used in this profile

    doco Documentation for this format

    Terminology Bindings (Differential)

    PathConformanceValueSetURI
    Observation.interpretationrequiredLOINC LL529-9
    http://loinc.org/vs/LL529-9

    Key Elements View

    NameFlagsCard.TypeDescription & Constraintsdoco
    .. Observation C 0..* USCoreObservationClinicalTestResultProfile Measurements and simple assertions
    obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
    obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
    us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present
    ... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
    ... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
    ... basedOn Σ 0..* Reference(ServiceRequest | CarePlan) Fulfills plan, proposal or order
    ... status ?!SΣ 1..1 code registered | preliminary | final | amended +
    Binding: ObservationStatus (required): Codes providing the status of an observation.

    ... Slices for category S 1..* CodeableConcept Classification of type of observation
    Slice: Unordered, Open by pattern:$this
    Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


    .... category:clinical-test S 1..1 CodeableConcept Classification of type of observation
    Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.



    Required Pattern: At least the following
    ..... coding 1..* Coding Code defined by a terminology system
    Fixed Value: (complex)
    ...... system 1..1 uri Identity of the terminology system
    Fixed Value: http://hl7.org/fhir/us/core/CodeSystem/us-core-observation-category
    ...... code 1..1 code Symbol in syntax defined by the system
    Fixed Value: clinical-test
    ... code SΣ 1..1 CodeableConcept Clinical Test Name
    Binding: US Core Clinical Test Codes (extensible)
    Required Pattern: At least the following
    .... coding 1..* Coding Code defined by a terminology system
    Fixed Value: (complex)
    ..... system 1..1 uri Identity of the terminology system
    Fixed Value: http://loinc.org
    ..... code 1..1 code Symbol in syntax defined by the system
    Fixed Value: 89247-1
    ... subject SΣ 1..1 Reference(Cancer Patient Profile) Who and/or what the observation is about
    ... effective[x] SΣC 0..1 Clinically relevant time/time-period for observation
    us-core-1: Datetime must be at least to day.
    .... effectiveDateTime dateTime
    ... value[x] SΣC 0..1 integer Result Value
    us-core-3: SHALL use UCUM for coded quantity units.
    ... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
    Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

    ... interpretation S 0..* CodeableConcept High, low, normal, etc.
    Binding: LOINC Answer List LL529-9 (required)
    ... bodySite 0..1 CodeableConcept Not used in this profile
    Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

    ... specimen 0..1 Reference(Specimen) Not used in this profile
    ... device 0..1 Reference(Device | DeviceMetric) Not used in this profile
    ... hasMember Σ 0..* Reference(Observation | QuestionnaireResponse | MolecularSequence) Not used in this profile
    ... component Σ 0..* BackboneElement Not used in this profile
    .... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
    .... code Σ 1..1 CodeableConcept Type of component observation (code / type)
    Binding: LOINCCodes (example): Codes identifying names of simple observations.


    doco Documentation for this format

    Terminology Bindings

    PathConformanceValueSet / CodeURI
    Observation.statusrequiredObservationStatus
    http://hl7.org/fhir/ValueSet/observation-status|4.0.1
    from the FHIR Standard
    Observation.categorypreferredObservationCategoryCodes
    http://hl7.org/fhir/ValueSet/observation-category
    from the FHIR Standard
    Observation.category:clinical-testpreferredPattern: clinical-test
    http://hl7.org/fhir/ValueSet/observation-category
    from the FHIR Standard
    Observation.codeextensiblePattern: LOINC code 89247-1
    http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-test-codes
    Observation.dataAbsentReasonextensibleDataAbsentReason
    http://hl7.org/fhir/ValueSet/data-absent-reason
    from the FHIR Standard
    Observation.interpretationrequiredLOINC LL529-9
    http://loinc.org/vs/LL529-9
    Observation.bodySiteexampleSNOMEDCTBodyStructures
    http://hl7.org/fhir/ValueSet/body-site
    from the FHIR Standard
    Observation.component.codeexampleLOINCCodes (a valid code from LOINC)
    http://hl7.org/fhir/ValueSet/observation-codes
    from the FHIR Standard

    Snapshot View

    NameFlagsCard.TypeDescription & Constraintsdoco
    .. Observation C 0..* USCoreObservationClinicalTestResultProfile Measurements and simple assertions
    obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
    obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
    us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present
    ... id Σ 0..1 id Logical id of this artifact
    ... meta Σ 0..1 Meta Metadata about the resource
    ... implicitRules ?!Σ 0..1 uri A set of rules under which this content was created
    ... language 0..1 code Language of the resource content
    Binding: CommonLanguages (preferred): A human language.

    Additional BindingsPurpose
    AllLanguages Max Binding
    ... text 0..1 Narrative Text summary of the resource, for human interpretation
    ... contained 0..* Resource Contained, inline Resources
    ... extension 0..* Extension Additional content defined by implementations
    ... modifierExtension ?! 0..* Extension Extensions that cannot be ignored
    ... identifier Σ 0..* Identifier Business Identifier for observation
    ... basedOn Σ 0..* Reference(ServiceRequest | CarePlan) Fulfills plan, proposal or order
    ... partOf Σ 0..* Reference(Procedure) Part of referenced event
    ... status ?!SΣ 1..1 code registered | preliminary | final | amended +
    Binding: ObservationStatus (required): Codes providing the status of an observation.

    ... Slices for category S 1..* CodeableConcept Classification of type of observation
    Slice: Unordered, Open by pattern:$this
    Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.


    .... category:clinical-test S 1..1 CodeableConcept Classification of type of observation
    Binding: ObservationCategoryCodes (preferred): Codes for high level observation categories.



    Required Pattern: At least the following
    ..... id 0..1 string Unique id for inter-element referencing
    ..... extension 0..* Extension Additional content defined by implementations
    ..... coding 1..* Coding Code defined by a terminology system
    Fixed Value: (complex)
    ...... id 0..1 string Unique id for inter-element referencing
    ...... extension 0..* Extension Additional content defined by implementations
    ...... system 1..1 uri Identity of the terminology system
    Fixed Value: http://hl7.org/fhir/us/core/CodeSystem/us-core-observation-category
    ...... version 0..1 string Version of the system - if relevant
    ...... code 1..1 code Symbol in syntax defined by the system
    Fixed Value: clinical-test
    ...... display 0..1 string Representation defined by the system
    ...... userSelected 0..1 boolean If this coding was chosen directly by the user
    ..... text 0..1 string Plain text representation of the concept
    ... code SΣ 1..1 CodeableConcept Clinical Test Name
    Binding: US Core Clinical Test Codes (extensible)
    Required Pattern: At least the following
    .... id 0..1 string Unique id for inter-element referencing
    .... extension 0..* Extension Additional content defined by implementations
    .... coding 1..* Coding Code defined by a terminology system
    Fixed Value: (complex)
    ..... id 0..1 string Unique id for inter-element referencing
    ..... extension 0..* Extension Additional content defined by implementations
    ..... system 1..1 uri Identity of the terminology system
    Fixed Value: http://loinc.org
    ..... version 0..1 string Version of the system - if relevant
    ..... code 1..1 code Symbol in syntax defined by the system
    Fixed Value: 89247-1
    ..... display 0..1 string Representation defined by the system
    ..... userSelected 0..1 boolean If this coding was chosen directly by the user
    .... text 0..1 string Plain text representation of the concept
    ... subject SΣ 1..1 Reference(Cancer Patient Profile) Who and/or what the observation is about
    ... focus Σ 0..* Reference(Resource) What the observation is about, when it is not about the subject of record
    ... encounter Σ 0..1 Reference(Encounter) Healthcare event during which this observation is made
    ... effective[x] SΣC 0..1 Clinically relevant time/time-period for observation
    us-core-1: Datetime must be at least to day.
    .... effectiveDateTime dateTime S
    .... effectivePeriod Period
    ... issued Σ 0..1 instant Date/Time this version was made available
    ... performer Σ 0..* Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Who is responsible for the observation
    ... value[x] SΣC 0..1 integer Result Value
    us-core-3: SHALL use UCUM for coded quantity units.
    ... dataAbsentReason SC 0..1 CodeableConcept Why the result is missing
    Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

    ... interpretation S 0..* CodeableConcept High, low, normal, etc.
    Binding: LOINC Answer List LL529-9 (required)
    ... note 0..* Annotation Comments about the observation
    ... bodySite 0..1 CodeableConcept Not used in this profile
    Binding: SNOMEDCTBodyStructures (example): Codes describing anatomical locations. May include laterality.

    ... method 0..1 CodeableConcept How it was done
    Binding: ObservationMethods (example): Methods for simple observations.

    ... specimen 0..1 Reference(Specimen) Not used in this profile
    ... device 0..1 Reference(Device | DeviceMetric) Not used in this profile
    ... referenceRange C 0..* BackboneElement Provides guide for interpretation
    obs-3: Must have at least a low or a high or text
    .... id 0..1 string Unique id for inter-element referencing
    .... extension 0..* Extension Additional content defined by implementations
    .... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
    .... low C 0..1 SimpleQuantity Low Range, if relevant
    .... high C 0..1 SimpleQuantity High Range, if relevant
    .... type 0..1 CodeableConcept Reference range qualifier
    Binding: ObservationReferenceRangeMeaningCodes (preferred): Code for the meaning of a reference range.

    .... appliesTo 0..* CodeableConcept Reference range population
    Binding: ObservationReferenceRangeAppliesToCodes (example): Codes identifying the population the reference range applies to.


    .... age 0..1 Range Applicable age range, if relevant
    .... text 0..1 string Text based reference range in an observation
    ... hasMember Σ 0..* Reference(Observation | QuestionnaireResponse | MolecularSequence) Not used in this profile
    ... derivedFrom Σ 0..* Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) Related measurements the observation is made from
    ... component Σ 0..* BackboneElement Not used in this profile
    .... id 0..1 string Unique id for inter-element referencing
    .... extension 0..* Extension Additional content defined by implementations
    .... modifierExtension ?!Σ 0..* Extension Extensions that cannot be ignored even if unrecognized
    .... code Σ 1..1 CodeableConcept Type of component observation (code / type)
    Binding: LOINCCodes (example): Codes identifying names of simple observations.

    .... value[x] Σ 0..1 Actual component result
    ..... valueQuantity Quantity
    ..... valueCodeableConcept CodeableConcept
    ..... valueString string
    ..... valueBoolean boolean
    ..... valueInteger integer
    ..... valueRange Range
    ..... valueRatio Ratio
    ..... valueSampledData SampledData
    ..... valueTime time
    ..... valueDateTime dateTime
    ..... valuePeriod Period
    .... dataAbsentReason C 0..1 CodeableConcept Why the component result is missing
    Binding: DataAbsentReason (extensible): Codes specifying why the result (Observation.value[x]) is missing.

    .... interpretation 0..* CodeableConcept High, low, normal, etc.
    Binding: ObservationInterpretationCodes (extensible): Codes identifying interpretations of observations.


    .... referenceRange 0..* See referenceRange (Observation) Provides guide for interpretation of component result

    doco Documentation for this format

    Terminology Bindings

    PathConformanceValueSet / CodeURI
    Observation.languagepreferredCommonLanguages
    Additional Bindings Purpose
    AllLanguages Max Binding
    http://hl7.org/fhir/ValueSet/languages
    from the FHIR Standard
    Observation.statusrequiredObservationStatus
    http://hl7.org/fhir/ValueSet/observation-status|4.0.1
    from the FHIR Standard
    Observation.categorypreferredObservationCategoryCodes
    http://hl7.org/fhir/ValueSet/observation-category
    from the FHIR Standard
    Observation.category:clinical-testpreferredPattern: clinical-test
    http://hl7.org/fhir/ValueSet/observation-category
    from the FHIR Standard
    Observation.codeextensiblePattern: LOINC code 89247-1
    http://hl7.org/fhir/us/core/ValueSet/us-core-clinical-test-codes
    Observation.dataAbsentReasonextensibleDataAbsentReason
    http://hl7.org/fhir/ValueSet/data-absent-reason
    from the FHIR Standard
    Observation.interpretationrequiredLOINC LL529-9
    http://loinc.org/vs/LL529-9
    Observation.bodySiteexampleSNOMEDCTBodyStructures
    http://hl7.org/fhir/ValueSet/body-site
    from the FHIR Standard
    Observation.methodexampleObservationMethods
    http://hl7.org/fhir/ValueSet/observation-methods
    from the FHIR Standard
    Observation.referenceRange.typepreferredObservationReferenceRangeMeaningCodes
    http://hl7.org/fhir/ValueSet/referencerange-meaning
    from the FHIR Standard
    Observation.referenceRange.appliesToexampleObservationReferenceRangeAppliesToCodes
    http://hl7.org/fhir/ValueSet/referencerange-appliesto
    from the FHIR Standard
    Observation.component.codeexampleLOINCCodes (a valid code from LOINC)
    http://hl7.org/fhir/ValueSet/observation-codes
    from the FHIR Standard
    Observation.component.dataAbsentReasonextensibleDataAbsentReason
    http://hl7.org/fhir/ValueSet/data-absent-reason
    from the FHIR Standard
    Observation.component.interpretationextensibleObservationInterpretationCodes
    http://hl7.org/fhir/ValueSet/observation-interpretation
    from the FHIR Standard

    This structure is derived from USCoreObservationClinicalTestResultProfile

    Summary

    Must-Support: 1 element

    Structures

    This structure refers to these other structures:

    Maturity: 4

     

    Other representations of profile: CSV, Excel, Schematron