This page is part of the Da Vinci Payer Data Exchange (v2.0.0-ballot: STU2 Ballot 1) based on FHIR R4. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/davinci-pdex/StructureDefinition/pdex-device | Version: 2.0.0-ballot | |||
Draft as of 2022-02-18 | Computable Name: PdexDevice |
The PDex Device profile is provided to enable payers to record information about devices used by a member that may not have a UDI number. FHIR-29796 PDex Device uses base resource not US Core Implantable Device Profile. Pdex-Device enables payers to record non-implantable device data. CGP Voted on variance approval: Drew Torres/Eric Haas: 9-0-0
US Core supports the US Core Implantable Device resource. However, payers may need to record information about other non-implantable devices that are used by their members. The PDex-Device profile is used to record this type of information.
NOTE: FHIR-29796: PDex Device uses base resource not US Core Implantable Device Profile. Pdex-Device enables payers to record non-implantable device data. CGP Voted on variance approval: Drew Torres/Eric Haas: 9-0-0
In future versions of this IG there is a desire to ensure that all Device identification information is exchanged using the PDex Device or US Core Implantable Device resource.
he essential fields (Must Support or Cardinality greater than 0..*) to be provided in the PDex Device resource are:
R4 Element | Name | Cardinality | Type |
---|---|---|---|
Device.type | type | 1..1 | CodeableConcept |
Device.patient | patient | 1..1 | Reference(US Core Patient Profile) |
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Device
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | Device | Item used in healthcare | |
![]() ![]() ![]() | S | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
![]() ![]() ![]() ![]() | S | 1..1 | string | Mandatory fixed portion of UDI |
![]() ![]() ![]() ![]() | S | 0..1 | base64Binary | UDI Machine Readable Barcode String |
![]() ![]() ![]() ![]() | S | 0..1 | string | UDI Human Readable Barcode String |
![]() ![]() ![]() | S | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
![]() ![]() ![]() | S | 0..1 | string | The distinct identification string |
![]() ![]() ![]() | S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) |
![]() ![]() ![]() | S | 0..1 | string | Lot number of manufacture |
![]() ![]() ![]() | S | 0..1 | string | Serial number assigned by the manufacturer |
![]() ![]() ![]() | S | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible) |
![]() ![]() ![]() | S | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed |
![]() ![]() ![]() | S | 0..1 | uri | Network address to contact device |
![]() |
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | Device | Item used in healthcare | |
![]() ![]() ![]() | Σ | 0..1 | string | Logical id of this artifact |
![]() ![]() ![]() | Σ | 0..1 | Meta | Metadata about the resource |
![]() ![]() ![]() | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred) Max Binding: AllLanguages: A human language. | |
![]() ![]() ![]() | 0..1 | Narrative | Text summary of the resource, for human interpretation | |
![]() ![]() ![]() | 0..* | Resource | Contained, inline Resources | |
![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() | 0..* | Identifier | Instance identifier | |
![]() ![]() ![]() | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |
![]() ![]() ![]() | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() | SΣ | 1..1 | string | Mandatory fixed portion of UDI |
![]() ![]() ![]() ![]() | 0..1 | uri | UDI Issuing Organization | |
![]() ![]() ![]() ![]() | 0..1 | uri | Regional UDI authority | |
![]() ![]() ![]() ![]() | SΣ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
![]() ![]() ![]() ![]() | SΣ | 0..1 | string | UDI Human Readable Barcode String |
![]() ![]() ![]() ![]() | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |
![]() ![]() ![]() | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
![]() ![]() ![]() | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |
![]() ![]() ![]() | S | 0..1 | string | The distinct identification string |
![]() ![]() ![]() | 0..1 | string | Name of device manufacturer | |
![]() ![]() ![]() | 0..1 | dateTime | Date when the device was made | |
![]() ![]() ![]() | S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) |
![]() ![]() ![]() | S | 0..1 | string | Lot number of manufacture |
![]() ![]() ![]() | S | 0..1 | string | Serial number assigned by the manufacturer |
![]() ![]() ![]() | 0..* | BackboneElement | The name of the device as given by the manufacturer | |
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() | 1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |
![]() ![]() ![]() | 0..1 | string | The model number for the device | |
![]() ![]() ![]() | 0..1 | string | The part number of the device | |
![]() ![]() ![]() | S | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible) |
![]() ![]() ![]() | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |
![]() ![]() ![]() ![]() | 0..1 | string | The version of the standard that is used to operate and communicate | |
![]() ![]() ![]() | 0..* | BackboneElement | The actual design of the device or software version running on the device | |
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() | 0..1 | CodeableConcept | The type of the device version | |
![]() ![]() ![]() ![]() | 0..1 | Identifier | A single component of the device version | |
![]() ![]() ![]() ![]() | 1..1 | string | The version text | |
![]() ![]() ![]() | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
![]() ![]() ![]() ![]() | 0..* | Quantity | Property value as a quantity | |
![]() ![]() ![]() ![]() | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |
![]() ![]() ![]() | S | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed |
![]() ![]() ![]() | 0..1 | Reference(Organization) | Organization responsible for device | |
![]() ![]() ![]() | 0..* | ContactPoint | Details for human/organization for support | |
![]() ![]() ![]() | 0..1 | Reference(Location) | Where the device is found | |
![]() ![]() ![]() | S | 0..1 | uri | Network address to contact device |
![]() ![]() ![]() | 0..* | Annotation | Device notes and comments | |
![]() ![]() ![]() | Σ | 0..* | CodeableConcept | Safety Characteristics of Device |
![]() ![]() ![]() | 0..1 | Reference(Device) | The parent device | |
![]() |
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | Device | Item used in healthcare | |
![]() ![]() ![]() | Σ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
![]() ![]() ![]() ![]() | Σ | 1..1 | string | Mandatory fixed portion of UDI |
![]() ![]() ![]() ![]() | Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
![]() ![]() ![]() ![]() | Σ | 0..1 | string | UDI Human Readable Barcode String |
![]() ![]() ![]() | ?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
![]() ![]() ![]() | 0..1 | string | The distinct identification string | |
![]() ![]() ![]() | 0..1 | dateTime | Date and time of expiry of this device (if applicable) | |
![]() ![]() ![]() | 0..1 | string | Lot number of manufacture | |
![]() ![]() ![]() | 0..1 | string | Serial number assigned by the manufacturer | |
![]() ![]() ![]() | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible) | |
![]() ![]() ![]() | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed | |
![]() ![]() ![]() | 0..1 | uri | Network address to contact device | |
![]() |
This structure is derived from Device
Differential View
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | Device | Item used in healthcare | |
![]() ![]() ![]() | S | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
![]() ![]() ![]() ![]() | S | 1..1 | string | Mandatory fixed portion of UDI |
![]() ![]() ![]() ![]() | S | 0..1 | base64Binary | UDI Machine Readable Barcode String |
![]() ![]() ![]() ![]() | S | 0..1 | string | UDI Human Readable Barcode String |
![]() ![]() ![]() | S | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
![]() ![]() ![]() | S | 0..1 | string | The distinct identification string |
![]() ![]() ![]() | S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) |
![]() ![]() ![]() | S | 0..1 | string | Lot number of manufacture |
![]() ![]() ![]() | S | 0..1 | string | Serial number assigned by the manufacturer |
![]() ![]() ![]() | S | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible) |
![]() ![]() ![]() | S | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed |
![]() ![]() ![]() | S | 0..1 | uri | Network address to contact device |
![]() |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() | 0..* | Device | Item used in healthcare | |
![]() ![]() ![]() | Σ | 0..1 | string | Logical id of this artifact |
![]() ![]() ![]() | Σ | 0..1 | Meta | Metadata about the resource |
![]() ![]() ![]() | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() | 0..1 | code | Language of the resource content Binding: CommonLanguages (preferred) Max Binding: AllLanguages: A human language. | |
![]() ![]() ![]() | 0..1 | Narrative | Text summary of the resource, for human interpretation | |
![]() ![]() ![]() | 0..* | Resource | Contained, inline Resources | |
![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() | ?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() | 0..* | Identifier | Instance identifier | |
![]() ![]() ![]() | 0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |
![]() ![]() ![]() | SΣ | 0..1 | BackboneElement | Unique Device Identifier (UDI) Barcode string |
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() | SΣ | 1..1 | string | Mandatory fixed portion of UDI |
![]() ![]() ![]() ![]() | 0..1 | uri | UDI Issuing Organization | |
![]() ![]() ![]() ![]() | 0..1 | uri | Regional UDI authority | |
![]() ![]() ![]() ![]() | SΣ | 0..1 | base64Binary | UDI Machine Readable Barcode String |
![]() ![]() ![]() ![]() | SΣ | 0..1 | string | UDI Human Readable Barcode String |
![]() ![]() ![]() ![]() | 0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |
![]() ![]() ![]() | ?!SΣ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required) |
![]() ![]() ![]() | 0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |
![]() ![]() ![]() | S | 0..1 | string | The distinct identification string |
![]() ![]() ![]() | 0..1 | string | Name of device manufacturer | |
![]() ![]() ![]() | 0..1 | dateTime | Date when the device was made | |
![]() ![]() ![]() | S | 0..1 | dateTime | Date and time of expiry of this device (if applicable) |
![]() ![]() ![]() | S | 0..1 | string | Lot number of manufacture |
![]() ![]() ![]() | S | 0..1 | string | Serial number assigned by the manufacturer |
![]() ![]() ![]() | 0..* | BackboneElement | The name of the device as given by the manufacturer | |
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() | 1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() | 1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |
![]() ![]() ![]() | 0..1 | string | The model number for the device | |
![]() ![]() ![]() | 0..1 | string | The part number of the device | |
![]() ![]() ![]() | S | 1..1 | CodeableConcept | The kind or type of device Binding: FHIRDeviceTypes (extensible) |
![]() ![]() ![]() | 0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() | 1..1 | CodeableConcept | The standard that is used to operate and communicate | |
![]() ![]() ![]() ![]() | 0..1 | string | The version of the standard that is used to operate and communicate | |
![]() ![]() ![]() | 0..* | BackboneElement | The actual design of the device or software version running on the device | |
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() | 0..1 | CodeableConcept | The type of the device version | |
![]() ![]() ![]() ![]() | 0..1 | Identifier | A single component of the device version | |
![]() ![]() ![]() ![]() | 1..1 | string | The version text | |
![]() ![]() ![]() | 0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |
![]() ![]() ![]() ![]() | 0..1 | string | Unique id for inter-element referencing | |
![]() ![]() ![]() ![]() | 0..* | Extension | Additional content defined by implementations | |
![]() ![]() ![]() ![]() | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() | 1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |
![]() ![]() ![]() ![]() | 0..* | Quantity | Property value as a quantity | |
![]() ![]() ![]() ![]() | 0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |
![]() ![]() ![]() | S | 1..1 | Reference(US Core Patient Profile) | Patient to whom Device is affixed |
![]() ![]() ![]() | 0..1 | Reference(Organization) | Organization responsible for device | |
![]() ![]() ![]() | 0..* | ContactPoint | Details for human/organization for support | |
![]() ![]() ![]() | 0..1 | Reference(Location) | Where the device is found | |
![]() ![]() ![]() | S | 0..1 | uri | Network address to contact device |
![]() ![]() ![]() | 0..* | Annotation | Device notes and comments | |
![]() ![]() ![]() | Σ | 0..* | CodeableConcept | Safety Characteristics of Device |
![]() ![]() ![]() | 0..1 | Reference(Device) | The parent device | |
![]() |
Other representations of profile: CSV, Excel, Schematron
Path | Conformance | ValueSet |
Device.language | preferred | CommonLanguages Max Binding: AllLanguages |
Device.udiCarrier.entryType | required | UDIEntryType |
Device.status | required | FHIRDeviceStatus |
Device.statusReason | extensible | FHIRDeviceStatusReason |
Device.deviceName.type | required | DeviceNameType |
Device.type | extensible | FHIRDeviceTypes |