This page is part of the Da Vinci Prior Authorization Support (PAS) FHIR IG (v2.1.0: STU 2) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/davinci-pas/StructureDefinition/profile-quantity | Version: 2.1.0 | |||
Standards status: Trial-use | Maturity Level: 3 | Computable Name: PASQuantity | ||
Other Identifiers: OID:2.16.840.1.113883.4.642.40.24.42.70 |
Constraints and extensions on SimpleQuantity which restricts the units.
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from SimpleQuantity
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Quantity | SimpleQuantity | |||
code | 0..1 | code | Coded form of the unit Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required) | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Quantity.code | required | https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Quantity | C | 0..* | SimpleQuantity | A fixed quantity (no comparator) ele-1: All FHIR elements must have a @value or children qty-3: If a code for the unit is present, the system SHALL also be present sqty-1: The comparator is not used on a SimpleQuantity |
code | Σ | 0..1 | code | Coded form of the unit Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required) ele-1: All FHIR elements must have a @value or children |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Quantity.code | required | https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Quantity | C | 0..* | SimpleQuantity | A fixed quantity (no comparator) qty-3: If a code for the unit is present, the system SHALL also be present sqty-1: The comparator is not used on a SimpleQuantity |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
value | Σ | 0..1 | decimal | Numerical value (with implicit precision) |
unit | Σ | 0..1 | string | Unit representation |
system | ΣC | 0..1 | uri | System that defines coded unit form |
code | Σ | 0..1 | code | Coded form of the unit Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required) |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Quantity.code | required | https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 |
This structure is derived from SimpleQuantity
Differential View
This structure is derived from SimpleQuantity
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Quantity | SimpleQuantity | |||
code | 0..1 | code | Coded form of the unit Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required) | |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Quantity.code | required | https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Quantity | C | 0..* | SimpleQuantity | A fixed quantity (no comparator) ele-1: All FHIR elements must have a @value or children qty-3: If a code for the unit is present, the system SHALL also be present sqty-1: The comparator is not used on a SimpleQuantity |
code | Σ | 0..1 | code | Coded form of the unit Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required) ele-1: All FHIR elements must have a @value or children |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Quantity.code | required | https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Quantity | C | 0..* | SimpleQuantity | A fixed quantity (no comparator) qty-3: If a code for the unit is present, the system SHALL also be present sqty-1: The comparator is not used on a SimpleQuantity |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
value | Σ | 0..1 | decimal | Numerical value (with implicit precision) |
unit | Σ | 0..1 | string | Unit representation |
system | ΣC | 0..1 | uri | System that defines coded unit form |
code | Σ | 0..1 | code | Coded form of the unit Binding: https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 (required) |
Documentation for this format |
Path | Conformance | ValueSet | URI |
Quantity.code | required | https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673https://valueset.x12.org/x217/005010/request/2000F/HSD/1/01/00/673 |
This structure is derived from SimpleQuantity
Other representations of profile: CSV, Excel, Schematron