Data Exchange For Quality Measures Implementation Guide
4.0.0 - STU4 United States of America

This page is part of the Da Vinci Data Exchange for Quality Measures (DEQM) FHIR IG (v4.0.0: STU4 (v4.0.0)) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

: Guidance Response Example - XML Representation

Raw xml | Download



<GuidanceResponse xmlns="http://hl7.org/fhir">
  <id value="guidanceresponse01"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/gaps-guidanceresponse-detailedcaregap"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: GuidanceResponse</b><a name="guidanceresponse01"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource GuidanceResponse &quot;guidanceresponse01&quot; </p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-gaps-guidanceresponse-detailedcaregap.html">Detailed Care Gap Guidance Response</a></p></div><p><b>module</b>: <a href="http://someguidelineprovider.org/radiology-appropriateness-guidelines.html">http://someguidelineprovider.org/radiology-appropriateness-guidelines.html</a></p><p><b>status</b>: success</p><p><b>subject</b>: <a href="Patient-patient01.html">Patient/patient01</a> &quot; WEBSTER&quot;</p><p><b>reasonCode</b>: Value is within specified range <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="CodeSystem-care-gap-reason.html">Care Gap Reasons Code System</a>#ValueInRange)</span></p></div>
  </text>
  <moduleUri
             value="http://someguidelineprovider.org/radiology-appropriateness-guidelines.html"/>
  <status value="success"/>
  <subject>
    <reference value="Patient/patient01"/>
  </subject>
  <reasonCode>
    <extension
               url="http://hl7.org/fhir/us/davinci-deqm/StructureDefinition/reasonDetail">
      <extension url="reference">
        <valueReference>
          <reference value="Observation/observation01"/>
        </valueReference>
      </extension>
      <extension url="path">
        <valueString value="value"/>
      </extension>
    </extension>
    <coding>
      <system
              value="http://hl7.org/fhir/us/davinci-deqm/CodeSystem/care-gap-reason"/>
      <code value="ValueInRange"/>
      <display value="Value is within specified range"/>
    </coding>
  </reasonCode>
</GuidanceResponse>