Data Exchange For Quality Measures Implementation Guide
5.0.0-ballot - STU5 Ballot United States of America flag

This page is part of the Da Vinci Data Exchange for Quality Measures (DEQM) FHIR IG (v5.0.0-ballot: STU5 (v5.0.0) Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 4.0.0. For a full list of available versions, see the Directory of published versions

: DEQM Submit Data - TTL Representation

Page standards status: Trial-use Maturity Level: 0

Raw ttl | Download


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:OperationDefinition ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "deqm.submit-data"] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: OperationDefinition deqm.submit-data</b></p><a name=\"deqm.submit-data\"> </a><a name=\"hcdeqm.submit-data\"> </a><a name=\"deqm.submit-data-en-US\"> </a><p>URL: [base]/Measure/$deqm-submit-data</p><p>Parameters</p><table class=\"grid\"><tr><td><b>Use</b></td><td><b>Name</b></td><td><b>Scope</b></td><td><b>Cardinality</b></td><td><b>Type</b></td><td><b>Binding</b></td><td><b>Documentation</b></td></tr><tr><td>IN</td><td>bundle</td><td/><td>1..*</td><td><a href=\"http://hl7.org/fhir/R4/bundle.html\">Bundle</a></td><td/><td><div><p>The Bundles that contain one or more MeasureReports and data of interest. See (<a href=\"guidance.html#deqm-operation-bundles-organized-by-subject\">Section 2.1.4</a>) for discussion about the Bundles.</p>\n</div></td></tr></table></div>"
  ] ; # 
  fhir:extension ( [
fhir:url [ fhir:v "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm"^^xsd:anyURI ] ;
fhir:value [ fhir:v "0"^^xsd:integer ]
  ] [
fhir:url [ fhir:v "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status"^^xsd:anyURI ] ;
fhir:value [ fhir:v "trial-use" ]
  ] [
fhir:url [ fhir:v "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"^^xsd:anyURI ] ;
fhir:value [ fhir:v "cqi" ]
  ] ) ; # 
  fhir:url [ fhir:v "http://hl7.org/fhir/us/davinci-deqm/OperationDefinition/deqm.submit-data"^^xsd:anyURI] ; # 
  fhir:version [ fhir:v "5.0.0-ballot"] ; # 
  fhir:name [ fhir:v "DEQMSubmitData"] ; # 
  fhir:title [ fhir:v "DEQM Submit Data"] ; # 
  fhir:status [ fhir:v "active"] ; # 
  fhir:kind [ fhir:v "operation"] ; # 
  fhir:date [ fhir:v "2024-07-24T10:53:32-05:00"^^xsd:dateTime] ; # 
  fhir:publisher [ fhir:v "HL7 International / Clinical Quality Information"] ; # 
  fhir:contact ( [
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "http://www.hl7.org/Special/committees/cqi" ]     ] )
  ] ) ; # 
  fhir:description [ fhir:v "The deqm-submit-data operation is used to submit MeasureReports and any data of interest for one or more measures for one or more subjects. Each submitted Bundle SHOULD contain resources for a single subject and SHOULD contain all of the MeasureReport and data of interest related to that subject."] ; # 
  fhir:jurisdiction ( [
    ( fhir:coding [
fhir:system [ fhir:v "urn:iso:std:iso:3166"^^xsd:anyURI ] ;
fhir:code [ fhir:v "US" ]     ] )
  ] ) ; # 
  fhir:code [ fhir:v "deqm-submit-data"] ; # 
  fhir:resource ( [ fhir:v "Measure"] ) ; # 
  fhir:system [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:type [ fhir:v "true"^^xsd:boolean] ; # 
  fhir:instance [ fhir:v "false"^^xsd:boolean] ; # 
  fhir:parameter ( [
fhir:name [ fhir:v "bundle" ] ;
fhir:use [ fhir:v "in" ] ;
fhir:min [ fhir:v "1"^^xsd:integer ] ;
fhir:max [ fhir:v "*" ] ;
fhir:documentation [ fhir:v "The Bundles that contain one or more MeasureReports and data of interest. See ([Section 2.1.4](guidance.html#deqm-operation-bundles-organized-by-subject)) for discussion about the Bundles." ] ;
fhir:type [ fhir:v "Bundle" ]
  ] ) . #