This page is part of the Da Vinci Data Exchange for Quality Measures (DEQM) FHIR IG (v5.0.0-ballot: STU5 (v5.0.0) Ballot 1) based on FHIR (HL7® FHIR® Standard) R4. The current version which supersedes this version is 4.0.0. For a full list of available versions, see the Directory of published versions
Page standards status: Trial-use | Maturity Level: 0 |
<OperationDefinition xmlns="http://hl7.org/fhir">
<id value="bulk-submit-data"/>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p>URL: [base]/Measure/$bulk-submit-data</p><p>URL: [base]/Measure/[id]/$bulk-submit-data</p><p>Parameters</p><table class="grid"><tr><td><b>Use</b></td><td><b>Name</b></td><td><b>Cardinality</b></td><td><b>Type</b></td><td><b>Binding</b></td><td><b>Documentation</b></td></tr><tr><td>IN</td><td>measureReport</td><td>1..*</td><td><a href="http://hl7.org/fhir/R4/measurereport.html">MeasureReport</a></td><td/><td><div><p>The measure report that is being submitted</p>
</div></td></tr><tr><td>IN</td><td>exportType</td><td>0..1</td><td><a href="http://hl7.org/fhir/R4/datatypes.html#code">code</a></td><td/><td><div><p>(Optional) String of <code>static</code> or <code>dynamic</code>. Defaults to <code>dynamic</code> if omitted.</p>
<p>If the value is <code>dynamic</code>, the Data Consumer will issue a POST request to the <code>exportUrl</code> to obtain a dataset from the Data Provider.</p>
<p>If the value is <code>static</code>, the Data Consumer will issue a GET request to the <code>exportUrl</code> to retrieve a Bulk Data manifest file with the location of the Bulk Data files.</p>
</div></td></tr><tr><td>IN</td><td>exportUrl</td><td>1..1</td><td><a href="http://hl7.org/fhir/R4/datatypes.html#url">url</a></td><td/><td><div><p>The absolute URL of the bulk export endpoint of a Data Provider (if the <code>exportType</code> parameter is <code>dynamic</code>) OR the location of a FHIR Bulk Data Export manifest file (if the <code>exportType</code> parameter is <code>static</code>)</p>
</div></td></tr><tr><td>IN</td><td>_type</td><td>0..*</td><td><a href="http://hl7.org/fhir/R4/datatypes.html#string">string</a></td><td/><td><div><p>(Optional) Restrict the data exported to only be specific FHIR resource types. See <a href="https://hl7.org/fhir/uv/bulkdata/export/index.html#query-parameters">the bulk data $export spec</a> for more information on '_type'</p>
</div></td></tr><tr><td>IN</td><td>useTypeFilters</td><td>0..1</td><td><a href="http://hl7.org/fhir/R4/datatypes.html#boolean">boolean</a></td><td/><td><div><p>(Optional) If enabled, data exported by the 'exportUrl' system will be filtered according to the data requirements of the Measure. Requires support of the _typeFilter experimental parameter in the export server. See <a href="https://hl7.org/fhir/uv/bulkdata/export/index.html#example-request-with-_typefilter">the bulk data $export spec</a> for more information on '_typeFilter'</p>
</div></td></tr></table></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
<valueInteger value="0"/>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
<valueCode value="trial-use"/>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
<valueCode value="cqi"/>
</extension>
<url
value="http://hl7.org/fhir/us/davinci-deqm/OperationDefinition/bulk-submit-data"/>
<version value="5.0.0-ballot"/>
<name value="BulkSubmitData"/>
<title value="Bulk Submit Data"/>
<status value="active"/>
<kind value="operation"/>
<date value="2022-11-09T10:53:32-05:00"/>
<publisher value="HL7 International / Clinical Quality Information"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/cqi"/>
</telecom>
</contact>
<description
value="The bulk-submit-data operation sends a bulk import request based on the data requirements of a FHIR Measure. This operation is modeled off the existing draft of the [Bulk Data Import Ping and Pull Approach](https://github.com/smart-on-fhir/bulk-import/blob/master/import-pnp.md)."/>
<jurisdiction>
<coding>
<system value="urn:iso:std:iso:3166"/>
<code value="US"/>
</coding>
</jurisdiction>
<code value="bulk-submit-data"/>
<resource value="Measure"/>
<system value="false"/>
<type value="true"/>
<instance value="true"/>
<parameter>
<name value="measureReport"/>
<use value="in"/>
<min value="1"/>
<max value="*"/>
<documentation value="The measure report that is being submitted"/>
<type value="MeasureReport"/>
</parameter>
<parameter>
<name value="exportType"/>
<use value="in"/>
<min value="0"/>
<max value="1"/>
<documentation
value="(Optional) String of `static` or `dynamic`. Defaults to `dynamic` if omitted.
If the value is `dynamic`, the Data Consumer will issue a POST request to the `exportUrl` to obtain a dataset from the Data Provider.
If the value is `static`, the Data Consumer will issue a GET request to the `exportUrl` to retrieve a Bulk Data manifest file with the location of the Bulk Data files."/>
<type value="code"/>
</parameter>
<parameter>
<name value="exportUrl"/>
<use value="in"/>
<min value="1"/>
<max value="1"/>
<documentation
value="The absolute URL of the bulk export endpoint of a Data Provider (if the `exportType` parameter is `dynamic`) OR the location of a FHIR Bulk Data Export manifest file (if the `exportType` parameter is `static`)"/>
<type value="url"/>
</parameter>
<parameter>
<name value="_type"/>
<use value="in"/>
<min value="0"/>
<max value="*"/>
<documentation
value="(Optional) Restrict the data exported to only be specific FHIR resource types. See [the bulk data $export spec](https://hl7.org/fhir/uv/bulkdata/export/index.html#query-parameters) for more information on '_type'"/>
<type value="string"/>
</parameter>
<parameter>
<name value="useTypeFilters"/>
<use value="in"/>
<min value="0"/>
<max value="1"/>
<documentation
value="(Optional) If enabled, data exported by the 'exportUrl' system will be filtered according to the data requirements of the Measure. Requires support of the _typeFilter experimental parameter in the export server. See [the bulk data $export spec](https://hl7.org/fhir/uv/bulkdata/export/index.html#example-request-with-_typefilter) for more information on '_typeFilter'"/>
<type value="boolean"/>
</parameter>
</OperationDefinition>