Data Exchange For Quality Measures STU3 for FHIR R4
2.1.0 - Ballot

This page is part of the Da Vinci Data Exchange for Quality Measures (DEQM) FHIR IG (v2.1.0: STU 3) based on FHIR R4. The current version which supercedes this version is 3.1.0. For a full list of available versions, see the Directory of published versions

CapabilityStatement: Reporter Client CapabilityStatement

Raw OpenAPI-Swagger Definition file | Download

Reporter Client CapabilityStatement

  • Implementation Guide Version: 2.1.0
  • FHIR Version: 4.0.1
  • Supported formats: xml, json
  • Published: 2020-07-05
  • Published by: HL7 International - Clinical Quality Information Work Group

This profile defines the expected capabilities of a Da Vinci DEQM Reporter Client when conforming to the Da Vinci DEQM Implementation Guide. Reporters include systems that are primary reporters of patient healthcare information and systems that consume data from Producers. This CapabilityStatement resource includes the complete list of the recommended Da Vinci DEQM profiles and RESTful operations that a Da Vinci DEQM Reporter Client could support. Clients have the option of choosing from this list based on their local use cases and other contextual requirements.

SHALL Support the Following Implementation Guides:

FHIR RESTful Capabilities

Da Vinci DEQM Producer Client SHALL support at least one of the following transactions defined in the Framework Section of this Implementation Guide:

  • Individual Reporting
  • Summary Reporting

Security:

For general security consideration refer to the Security and Privacy Considerations.

Summary of System Wide Interactions

  • SHALL support the transaction interaction.
  • MAY support the batch interaction.
  • MAY support the search-system interaction.
  • MAY support the history-system interaction.
  • RESTful Capabilities by Resource/Profile:

    Summary of Search Criteria

    Resource TypeSupported ProfilesSupported SearchesSupported _includesSupported _revincludesSupported Operations
    MeasureReportDEQM Summary MeasureReport Profile, DEQM Individual MeasureReport Profile

    MeasureReport

    Conformance Expectation: SHALL

    Supported Profiles: DEQM Summary MeasureReport Profile, DEQM Individual MeasureReport Profile

    Resource Specific Documentation:

    The DaVinci DEQM Reporter Client SHALL be capable of supporting at least one of the DEQM MeasureReport Profiles listed above and all the DEQM, CQFM and QI Core Profiles they reference.

    Profile Interaction Summary:

    • SHALL support create.
    • SHOULD support update, delete.

    Fetch and Search Criteria: