This page is part of the Da Vinci Coverage Requirements Discovery (CRD) FHIR IG (v0.1.0: STU 1 Ballot 1) based on FHIR v3.5.0. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions
Definitions for the profile-devicerequest-stu3 Profile.
DeviceRequest | |
Definition | Represents a request for a patient to employ a medical device. The device may be an implantable device, or an external assistive device, such as a walker. |
Control | 0..* |
Invariants | Defined on this element dom-1: If the resource is contained in another resource, it SHALL NOT contain any narrative (: contained.text.empty()) dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (: contained.contained.empty()) dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource (: contained.where(('#'+id in %resource.descendants().reference).not()).empty()) dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()) |
DeviceRequest.id | |
Definition | The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. |
Control | 0..1 |
Type | id |
Comments | The only time that a resource does not have an id is when it is being submitted to the server using a create operation. |
DeviceRequest.meta | |
Definition | The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content may not always be associated with version changes to the resource. |
Control | 0..1 |
Type | Meta |
DeviceRequest.implicitRules | |
Definition | A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. |
Control | 0..1 |
Type | uri |
Is Modifier | true |
Comments | Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. This element is labelled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation. |
DeviceRequest.language | |
Definition | The base language in which the resource is written. |
Control | 0..1 |
Binding | A human language. The codes SHALL be taken from Common Languages; other codes may be used where these codes are not suitable |
Type | code |
Comments | Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). |
DeviceRequest.text | |
Definition | A human-readable narrative that contains a summary of the resource, and may be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. |
Control | 0..1 This element is affected by the following invariants: dom-1 |
Type | Narrative |
Alternate Names | narrative, html, xhtml, display |
Comments | Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded in formation is added later. |
DeviceRequest.contained | |
Definition | These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. |
Control | 0..* |
Type | Resource |
Alternate Names | inline resources, anonymous resources, contained resources |
Comments | This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. |
DeviceRequest.extension | |
Definition | An Extension |
Control | 0..* |
Type | Extension |
DeviceRequest.extension ([CanonicalType[http://hl7.org/fhir/us/davinci-crd/STU3/StructureDefinition/ext-insurance]]) | |
Definition | Indicates coverage relevant to the appointment. |
Control | 1..1 This element is affected by the following invariants: ele-1 |
Type | (Extension Type: Reference(CRD Coverage)) |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() | (children().count() > id.count())) ext-1: Must have either extensions or value[x], not both (: extension.exists() != value.exists()) |
DeviceRequest.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the resource, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. |
Control | 0..* |
Type | Extension |
Is Modifier | true |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
DeviceRequest.identifier | |
Definition | Identifiers assigned to this order by the orderer or by the receiver. |
Note | This is a business identifer, not a resource identifier (see discussion) |
Control | 0..* |
Type | Identifier |
Must Support | true |
DeviceRequest.definition | |
Definition | Protocol or definition followed by this request. For example: The proposed act must be performed if the indicated conditions occur, e.g.., shortness of breath, SpO2 less than x%. |
Control | 1..1 |
Type | Reference(ActivityDefinition | PlanDefinition) |
Must Support | true |
DeviceRequest.basedOn | |
Definition | Plan/proposal/order fulfilled by this request. |
Control | 1..1 |
Type | Reference(Resource) |
Must Support | true |
DeviceRequest.priorRequest | |
Definition | The request takes the place of the referenced completed or terminated request(s). |
Control | 0..* |
Type | Reference(Resource) |
DeviceRequest.groupIdentifier | |
Definition | Composite request this is part of. |
Control | 0..1 |
Type | Identifier |
Comments | potentially relevant for CRD in some situations. |
DeviceRequest.status | |
Definition | The status of the request. |
Control | 1..1 |
Binding | Codes representing the status of the request. The codes SHALL be taken from RequestStatus |
Type | code |
Is Modifier | true |
Must Support | true |
Comments | This element is labeled as a modifier because the status contains the codes cancelled and entered-in-error that mark the request as not currently valid. |
Fixed Value | draft |
DeviceRequest.intent | |
Definition | Whether the request is a proposal, plan, an original order or a reflex order. |
Control | 1..1 |
Binding | The kind of diagnostic request The codes SHALL be taken from http://hl7.org/fhir/2018Sep/valueset-request-intent.html |
Type | CodeableConcept |
Is Modifier | true |
Comments | potentially relevant for CRD in some situations. |
DeviceRequest.priority | |
Definition | Indicates how quickly the should be addressed with respect to other requests. |
Control | 0..1 |
Binding | Identifies the level of importance to be assigned to actioning the request The codes SHALL be taken from RequestPriority |
Type | code |
Default Value | If missing, normal priority |
DeviceRequest.code[x] | |
Definition | The details of the device to be used. |
Control | 1..1 |
Binding | Codes for devices that can be requested For example codes, see FHIR Device Types |
Type | Choice of: Reference(CRD Device), CodeableConcept |
[x] Note | See Choice of Data Types for further information about how to use [x] |
Must Support | true |
DeviceRequest.subject | |
Definition | The patient who will use the device. |
Control | 1..1 |
Type | Reference(CRD Patient) |
Must Support | true |
DeviceRequest.context | |
Definition | An encounter that provides additional context in which this request is made. |
Control | 0..1 |
Type | Reference(CRD Encounter) |
Comments | potentially relevant for CRD in some situations. |
DeviceRequest.occurrence[x] | |
Definition | The timing schedule for the use of the device. The Schedule data type allows many different expressions, for example. "Every 8 hours"; "Three times a day"; "1/2 an hour before breakfast for 10 days from 23-Dec 2011:"; "15 Oct 2013, 17 Oct 2013 and 1 Nov 2013". |
Control | 0..1 |
Type | Choice of: dateTime, Period, Timing |
[x] Note | See Choice of Data Types for further information about how to use [x] |
Must Support | true |
DeviceRequest.authoredOn | |
Definition | When the request transitioned to being actionable. |
Control | 1..1 |
Type | dateTime |
Must Support | true |
DeviceRequest.requester | |
Definition | The individual who initiated the request and has responsibility for its activation. |
Control | 1..1 |
Type | BackboneElement |
Must Support | true |
Invariants | Defined on this element ele-1: All FHIR elements must have a @value or children (: hasValue() | (children().count() > id.count())) |
DeviceRequest.requester.id | |
Definition | unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Control | 0..1 |
Type | string |
DeviceRequest.requester.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
DeviceRequest.requester.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. |
Control | 0..* |
Type | Extension |
Is Modifier | true |
Alternate Names | extensions, user content, modifiers |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
DeviceRequest.requester.agent | |
Definition | The device, practitioner, etc. who initiated the request. |
Control | 1..1 |
Type | Reference(CRD Practitioner) |
Must Support | true |
DeviceRequest.requester.onBehalfOf | |
Definition | The organization the device or practitioner was acting on behalf of. |
Control | 0..1 |
Type | Reference(Organization) |
Requirements | Practitioners and Devices can be associated with multiple organizations. This element indicates which organization they were acting on behalf of when authoring the request. |
Comments | potentially relevant for CRD in some situations. |
DeviceRequest.performerType | |
Definition | Desired type of performer for doing the diagnostic testing. |
Control | 0..1 |
Binding | Indicates specific responsibility of an individual within the care team, such as "Primary physician", "Team coordinator", "Caregiver", etc. For example codes, see Participant Roles |
Type | CodeableConcept |
Comments | potentially relevant for CRD in some situations. |
DeviceRequest.performer | |
Definition | The desired perfomer for doing the diagnostic testing. |
Control | 0..1 |
Type | Reference(CRD Practitioner) |
Must Support | true |
DeviceRequest.reasonCode | |
Definition | Reason or justification for the use of this device. |
Control | 0..* |
Binding | Diagnosis or problem codes justifying the reason for requesting the device. For example codes, see Condition/Problem/Diagnosis Codes |
Type | CodeableConcept |
Must Support | true |
DeviceRequest.reasonReference | |
Definition | Reason or justification for the use of this device. |
Control | 0..* |
Type | Reference(US Core Condition Profile | US Core Result Observation) |
Must Support | true |
Comments | potentially relevant for CRD in some situations. |
DeviceRequest.supportingInfo | |
Definition | Additional clinical information about the patient that may influence the request fulfilment. For example, this may includes body where on the subject's the device will be used ( i.e. the target site). |
Control | 0..* |
Type | Reference(Resource) |
Requirements | Knowing where the device is targeted is important for tracking if multiple sites are possible. |
Comments | potentially relevant for CRD in some situations. |
DeviceRequest.note | |
Definition | Details about this request that were not represented at all or sufficiently in one of the attributes provided in a class. These may include for example a comment, an instruction, or a note associated with the statement. |
Control | 0..* |
Type | Annotation |
Comments | potentially relevant for CRD in some situations. |
DeviceRequest.relevantHistory | |
Definition | Key events in the history of the request. |
Control | 0..* |
Type | Reference(Provenance) |
Comments | potentially relevant for CRD in some situations. |