This page is part of the Da Vinci Coverage Requirements Discovery (CRD) FHIR IG (v0.1.0: STU 1 Ballot 1) based on FHIR v3.5.0. The current version which supercedes this version is 1.0.0. For a full list of available versions, see the Directory of published versions

This is a pre-release version (Ballot 1) of Coverage Requirements Discovery (CRD) R1/STU. There is no current official version.
For a full list of available versions, see the Directory of published versions .

StructureDefinition: CRD Device

The official URL for this profile is:

http://hl7.org/fhir/us/davinci-crd/STU3/StructureDefinition/profile-device-stu3

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from US Core Implanted Device Profile

Summary

Must-Support: 1 element

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device I0..*US Core Implanted Device Profile
... id Σ0..1idLogical id of this artifact
... meta Σ0..1MetaMetadata about the resource
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: Common Languages (extensible)
... text I0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... extension 0..*ExtensionAdditional Content defined by implementations
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... identifier 0..*IdentifierInstance identifier
... udi SΣI1..1BackboneElementUnique Device Identifier (UDI) Barcode string
.... id 0..1stringxml:id (or equivalent in JSON)
.... extension 0..*ExtensionAdditional Content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored
.... deviceIdentifier SΣ0..1stringMandatory fixed portion of UDI
.... name Σ0..1stringDevice Name as appears on UDI label
.... jurisdiction 0..1uriRegional UDI authority
.... carrierHRF Σ0..1stringUDI Human Readable Barcode String
.... carrierAIDC Σ0..1base64BinaryUDI Machine Readable Barcode String
.... issuer 0..1uriUDI Issuing Organization
.... entryType 0..1codebarcode | rfid | manual +
Binding: UDIEntryType (required)
... status ?!Σ0..1codeactive | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required)
... type S1..1CodeableConceptWhat kind of device this is
Binding: FHIR Device Types (extensible)
... lotNumber 0..1stringLot number of manufacture
... manufacturer 0..1stringName of device manufacturer
... manufactureDate 0..1dateTimeDate when the device was made
... expirationDate 0..1dateTimeDate and time of expiry of this device (if applicable)
... model 0..1stringModel id assigned by the manufacturer
... version 0..1stringVersion number (i.e. software)
... patient S1..1Reference(US Core Patient Profile)Patient to whom Device is affixed
... owner 0..1Reference(Organization)Organization responsible for device
... contact 0..*ContactPointDetails for human/organization for support
... location 0..1Reference(Location)Where the resource is found
... url 0..1uriNetwork address to contact device
... note 0..*AnnotationDevice notes and comments
... safety Σ0..*CodeableConceptSafety Characteristics of Device
Binding: DeviceSafety (example)

doco Documentation for this format

This structure is derived from US Core Implanted Device Profile

Summary

Must-Support: 1 element

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device I0..*US Core Implanted Device Profile
... id Σ0..1idLogical id of this artifact
... meta Σ0..1MetaMetadata about the resource
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: Common Languages (extensible)
... text I0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... extension 0..*ExtensionAdditional Content defined by implementations
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... identifier 0..*IdentifierInstance identifier
... udi SΣI1..1BackboneElementUnique Device Identifier (UDI) Barcode string
.... id 0..1stringxml:id (or equivalent in JSON)
.... extension 0..*ExtensionAdditional Content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored
.... deviceIdentifier SΣ0..1stringMandatory fixed portion of UDI
.... name Σ0..1stringDevice Name as appears on UDI label
.... jurisdiction 0..1uriRegional UDI authority
.... carrierHRF Σ0..1stringUDI Human Readable Barcode String
.... carrierAIDC Σ0..1base64BinaryUDI Machine Readable Barcode String
.... issuer 0..1uriUDI Issuing Organization
.... entryType 0..1codebarcode | rfid | manual +
Binding: UDIEntryType (required)
... status ?!Σ0..1codeactive | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required)
... type S1..1CodeableConceptWhat kind of device this is
Binding: FHIR Device Types (extensible)
... lotNumber 0..1stringLot number of manufacture
... manufacturer 0..1stringName of device manufacturer
... manufactureDate 0..1dateTimeDate when the device was made
... expirationDate 0..1dateTimeDate and time of expiry of this device (if applicable)
... model 0..1stringModel id assigned by the manufacturer
... version 0..1stringVersion number (i.e. software)
... patient S1..1Reference(US Core Patient Profile)Patient to whom Device is affixed
... owner 0..1Reference(Organization)Organization responsible for device
... contact 0..*ContactPointDetails for human/organization for support
... location 0..1Reference(Location)Where the resource is found
... url 0..1uriNetwork address to contact device
... note 0..*AnnotationDevice notes and comments
... safety Σ0..*CodeableConceptSafety Characteristics of Device
Binding: DeviceSafety (example)

doco Documentation for this format

 

Other representations of profile: Schematron

Terminology Bindings

PathNameConformanceValueSet
Device.languageCommon LanguagesextensibleCommon Languages
Device.udi.entryTypeUDIEntryTyperequiredUDIEntryType
Device.statusFHIRDeviceStatusrequiredFHIRDeviceStatus
Device.typeFHIR Device TypesextensibleFHIR Device Types
Device.safetyDeviceSafetyexampleDeviceSafety

Constraints

IdPathDetailsRequirements
dom-2DeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-1DeviceIf the resource is contained in another resource, it SHALL NOT contain any narrative
: contained.text.empty()
dom-4DeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-3DeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource
: contained.where(('#'+id in %resource.descendants().reference).not()).empty()
ele-1Device.udiAll FHIR elements must have a @value or children
: hasValue() | (children().count() > id.count())