This page is part of the Quality Measure STU2 for FHIR R4 Implementation Guide (v5.0.0: STU5 (v5.0.0)) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions
Contents:
This page provides a list of the FHIR artifacts defined as part of this implementation guide.
The following artifacts define the specific capabilities that different types of systems are expected to have in order to comply with this implementation guide. Systems conforming to this implementation guide are expected to declare conformance to one or more of the following capability statements.
CQF Measures Authoring Measure Repository Capability Statement |
Capability statement for a repository service supporting additional authoring and content workflow capabilities for FHIR-based measure specifications above the basic ShareableMeasureRepository. |
CQF Measures Publishable Measure Repository Capability Statement |
Capability statement for a repository service supporting additional publishing capabilities for FHIR-based measure specifications above the basic ShareableMeasureRepository. |
CQF Measures Shareable Measure Repository Capability Statement |
Capability statement for a repository service supporting minimum required capabilities to share FHIR-based measure specifications. See the Publishable and Authoring Measure Repository capability statements for more comprehensive support for publishing and authoring workflows. |
Measure Calculation Service Capability Statement Example |
Basic conformance statement for a Measure Calculation Service. A server can support more functionality than defined here, but this is the minimum amount |
These are custom operations that can be supported by and/or invoked by systems conforming to this implementation guide.
CQFM Package |
Packages a specified canonical resource with dependencies. |
These define logic, asset collections and other libraries as part of content in this implementation guide.
Adult Outpatient Encounters Common Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
Advanced Illness and Frailty Exclusion Library |
Advanced Illness and Frailty Exclusion Example Library |
BCS Component Library |
This library is the primary measure library for the Breast Cancer Screening component of the composite measure examples in this implementation guide. |
CCS Component Library |
This library is the primary measure library for the Cervical Cancer Screening component of the composite measure examples in this implementation guide. |
Common Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
Common Terminology Library |
This library is the common library for the terminology example measure |
EXM108 - Venous Thromboembolism Prophylaxis Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
EXM124 - Cervical Cancer Screening Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
EXM125 - Breast Cancer Screening Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
EXM130 - Colorectal Cancer Screening Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
EXM146 - Example Proportion Measure Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
EXM55 - Median Emergency Department Visit Duration Library (Example Continuous Variable Measure Library) |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
EXMRatio - Example Ratio Measure Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
Example Computable Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
Example Executable Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
Example Logic Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
Example Logic Library - Module Definition |
This library is used as an example module definition in the FHIR Quality Measure Implementation Guide |
Example Logic Library - Module Definition Direct Reference |
This library is used as an example module definition in the FHIR Quality Measure Implementation Guide |
Example Publishable Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
FHIR Model Definition (STU2) |
Model definition for the DSTU2 FHIR Model |
HBP Component Library |
Preventive Care and Screening: Screening for High Blood Pressure and Follow-Up Documented |
Hospice FHIR Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
MAT Global Common Functions FHIR Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
Module Definition Example Logic Library |
This library is used as an example module definition in the FHIR Quality Measure Implementation Guide |
Multi Rate Example Logic Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
PVS Component Library |
Pneumococcal Vaccination Status for Older Adults |
Quality Program Example |
This library is an example quality program illustrating the use of a library to identify the set of measures that are specified for use in a quality program. The measures specified here are expected to be used with the version information specified in the eCQM Update 2024 content release manifest, as indicated by the dependency on that library. |
RiskAdjustment_FHIR2 |
Example library illustrating risk adjustment with FHIR DSTU2 |
Supplemental Data Elements Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
TJC Overall Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
TSC Component Library |
Preventive Care and Screening: Tobacco Use: Screening and Cessation Intervention |
Terminology Library |
This library is the primary measure library for the terminology example measure |
VTE ICU Library |
This library is used as an example in the FHIR Quality Measure Implementation Guide |
eCQM Update 2024 - Final Draft |
This library is an example final draft of a version manifest (also referred to as an expansion profile) that specifies expansion rules for a set of value sets used for an example set of quality measures. |
eCQM Update 2024 - Initial Draft |
This library is an example initial draft of a version manifest (also referred to as an expansion profile) that specifies expansion rules for a set of value sets used for an example set of CMS measures. |
eCQM Update 2024 - Release |
This library is an example release of a version manifest (also referred to as an expansion profile) that specifies expansion rules for a set of value sets used for an example set of EP/EC measures. |
These define constraints on FHIR resources for systems conforming to this implementation guide.
CQFM Attestation Measure |
The CQFM Attestation Measure Profile describes an attestation scoring measure. |
CQFM CQL Measure |
The CQFM CQL Measure Profile describes minimum expectations for a computable electronic Quality Measure (QM) that uses Clinical Quality Language to represent computable logic in the measure. |
CQFM Cohort Measure |
The CQFM Cohort Measure Profile describes a cohort scoring measure. For more information on the usage of this profile, refer to the Profiles and Packaging pages in this implementation guide. |
CQFM Composite Measure |
The CQFM Composite Measure Profile describes minimum expectations for a composite electronic Quality Measure (QM). For more information on the usage of this profile, refer to the Profiles and Packaging pages in this implementation guide. |
CQFM Computable Measure |
The CQFM Computable Measure Profile describes minimum expectations for a computable electronic Quality Measure (QM), including the use of a computable library. For more information on the usage of this profile, refer to the Profiles and Packaging pages in this implementation guide. |
CQFM Continuous Variable Measure |
The CQFM Continuous Variable Measure Profile describes a continuous variable scoring measure. For more information on the usage of this profile, refer to the Profiles and Packaging pages in this implementation guide. |
CQFM Device |
The SoftwareSystem device profile is used to capture software details about the various systems used in authoring, testing, packaging, or evaluation of a knowledge artifact |
CQFM ELM Measure |
The CQFM ELM Measure Profile describes minimum expectations for an executable electronic Clinical Quality Measure (eCQM) that uses ELM (i.e. compiled CQL) to represent the logic of the measure. |
CQFM Executable Measure |
The CQFM Executable Measure Profile describes minimum expectations for an executable electronic Quality Measure (QM), including a reference to an executable library. For more information on the usage of this profile, refer to the Profiles and Packaging pages in this implementation guide. |
CQFM Proportion Measure |
The CQFM Proportion Measure Profile describes a proportion scoring measure. For more information on the usage of this profile, refer to the Profiles and Packaging pages in this implementation guide. |
CQFM Publishable Measure |
The CQFM Publishable Measure profile defines the minimum expectations to enable appropriate content management, discovery, and utilization of published Quality Measures (QMs). For more information on the usage of this profile, refer to the Profiles and Packaging pages in this implementation guide. |
CQFM Ratio Measure |
The CQFM Ratio Measure Profile describes a ratio scoring measure. For more information on the usage of this profile, refer to the Profiles and Packaging pages in this implementation guide. |
CQFM Test Case |
The CQFM Test Case Profile describes expectations for the definition and exchange of a measure test case, including input data and parameters, as well as expected outcome |
These define constraints on FHIR data types for systems conforming to this implementation guide.
CQFM Aggregate Method |
Specifies which method to be used to aggregate the measure observation values. |
CQFM Applies To |
Indicates the population that this stratifier should apply to. If no appliesTo extension is present, the stratifier is calculated based on the result of the population calculation (e.g. the calculated numerator for a proportion scoring). |
CQFM Component |
Specifies an artifact this is a component of a composite artifact. |
CQFM Composite Scoring |
Indicates how the calculation is performed for the measure, including proportion, ratio, continuous-variable, and cohort. The value set is extensible, allowing additional measure scoring types to be represented. When present on a group, specifies the scoring to be used for this group, overriding the scoring specified for the overall measure. |
CQFM Criteria Reference |
Specifies which population criteria is the input to an observation definition, or the initial population for a ratio numerator or denominator. |
CQFM Effective Period Anchor |
Specifies the anchor date for the effective period as defined by a starting date and a range. |
CQFM Effective Period Duration |
Specifies the reporting period for the measure. |
CQFM Group Id |
Specifies the id of a particular group within the measure referenced by the related artifact resource. |
CQFM Improvement Notation |
Information on whether an increase or decrease in score is the preferred result (e.g., a higher score indicates better quality OR a lower score indicates better quality OR quality is within a range). Additional Guidance: improvementNotation
Please provide comments on this additional code and if there are other codes needed in the improvement notation value set. If an additional code is added to the improvement notation (like normative reference range as suggested), where is guidance about the reference range best included in the specification for implementer use? Some suggestions include: the guidance field, the rate aggregation field or adding an extension to improvementNotation to add text. |
CQFM Include In Report Type |
Indicates what types of report the element on which it appears should be included in. If no values are specified, the default behavior is that elements are included in all report types |
CQFM Is Test Case |
Indicates whether this instance represents the definition of a test case. |
CQFM Operation |
Specifies the operation definition |
CQFM Population Basis |
The population basis specifies the type of elements in the population. For a subject-based measure, this is boolean (because the subject and the population basis are the same, and the population criteria define yes/no values for each individual in the population). For measures that have a population basis that is different than the subject, this element specifies the type of the population basis. For example, an encounter-based measure has a subject of Patient and a population basis of Encounter, and the population criteria all return lists of Encounters. Note that the subject of a measure can be found in the element subject[x]. |
CQFM Rate Aggregation |
Describes how to combine the information calculated, based on logic in each of several populations, into one summarized result. |
CQFM Risk Adjustment |
A description of the risk adjustment factors that may impact the resulting score for the measure and how they may be accounted for when computing and reporting measure results. |
CQFM Scoring |
Indicates how the calculation is performed for the measure, including proportion, ratio, continuous-variable, and cohort. The value set is extensible, allowing additional measure scoring types to be represented. When present on a group, specifies the scoring to be used for this group, overriding the scoring specified for the overall measure. |
CQFM Scoring Precision |
The number of decimal places to include in the score when the score is a decimal-valued result. |
CQFM Scoring Unit |
Defines the expected units of measure for the measure score. |
CQFM Supplemental Data Guidance |
Provides additional guidance on the meaning and reporting of supplemental data elements included in the measure overall. |
CQFM Test Case Description |
Provides a clear description of the test case. |
CQFM Type |
Indicates whether the measure is used to examine a process, an outcome over time, a patient-reported outcome, or a structure measure such as utilization. |
CQFM Weight |
What is the weight of the contribution of this measure to the overall score. |
These define sets of codes used by systems conforming to this implementation guide.
Chronic Liver Disease Legacy Example |
This is an example value set consisting of a subset of codes selected from Chronic Liver Disease (2.16.840.1.113883.3.464.1003.199.11.1065) for the purposes of illustrating a value set containing Legacy Codes. |
Intended Venue |
The Intended Venue value set identifies codes used to distinguish measures that are developed with the intent to be used in a particular venue, establishing expectations for the types of data that will be available from systems in that environment. |
Subject Type Value Set |
This value incorporates all of the codes from the FHIR value set subject-type in addition to PractitionerRole and RelatedPerson from the FHIR resource-types code system. |
These define new code systems used by systems conforming to this implementation guide.
Intended Venue Codes |
The Intended Venue code system defines codes used to distinguish measures that are developed with the intent to be used in a particular venue, establishing expectations for the types of data that will be available from systems in that environment. |
These define transformations to convert between codes by systems conforming with this implementation guide.
Aggregate Method mapping |
The mapping of FHIR aggregate method codes to the corresponding HL7 V3 code used in HQMF for each type of aggregate method |
Composite Measure Scoring mapping |
The mapping of FHIR composite measure scoring codes to the corresponding HL7 V3 code used in HQMF for each type of composite measure scoring |
Data Usage Mapping |
The mapping of FHIR measure data usage codes to the corresponding HL7 V3 code used in HQMF for each of the measure data usages |
Improvement Notation Mapping |
The mapping of FHIR improvement notation codes to the corresponding HL7 V3 code used in HQMF for each of the improvement notations |
Measure Population criteria mapping |
The mapping of FHIR measure population criteria codes to the corresponding HL7 V3 code used in HQMF for each of the measure population criteria components |
Measure Scoring mapping |
The mapping of FHIR measure scoring codes to the corresponding HL7 V3 code used in HQMF for each type of measure scoring |
Measure Type mapping |
The mapping of FHIR measure type codes to the corresponding HL7 V3 code used in HQMF for each of the measure type |
These are example instances that show what data produced and consumed by systems conforming with this implementation guide might look like.
Breast Cancer Screening |
This is an example only. |
Bundle example |
Example of a transaction bundle |
Cervical Cancer EXM146 - Appropriate Testing for Children with Pharyngitis |
Percentage of children 2-18 years of age who were diagnosed with pharyngitis, ordered an antibiotic and received a group A streptococcus (strep) test for the episode. |
Cervical Cancer Screening |
This is only an example. |
Device - Software System Example |
Example of a Software System Device used to illustrate tooling, testing, or authoring system |
EXM Measure |
An example FHIR-based measure. |
EXM Promoting Interoperability Measure |
An example FHIR-based attestation measure - Promoting Interoperability. |
EXM Ratio Measure |
An example FHIR-based ratio measure. |
EXM108 - Venous Thromboembolism Prophylaxis |
This measure assesses the number of patients who received VTE prophylaxis or have documentation why no VTE prophylaxis was given the day of or the day after hospital admission or surgery end date for surgeries that start the day of or the day after hospital admission. |
EXM124 - Cervical Cancer Screening |
Percentage of women 21-64 years of age who were screened for cervical cancer. |
EXM125 - Breast Cancer Screening |
Percentage of women 50-74 years of age who had a mammogram to screen for breast cancer. |
EXM130 - Colorectal Cancer Screening Measure |
Percentage of adults 50-75 years of age who had appropriate screening for colorectal cancer. |
EXM55 - Median Emergency Department Visit Duration |
This example illustrates a continuous variable measure represented as a FHIR eCQM |
Measure Content Bundle - Additional Supplemental Data Example |
Example of a Measure illustrating the use of supplemental data elements to gather additional information about a population |
MeasureReport - Test Case Example |
Example of a MeasureReport illustrating a test case |
Multi-Rate Example Measure |
This measure example illustrates the use of the group-level computation extensions to describe a multi-rate measure with mixed population bases. |
Pneumococcal Vaccination Status for Older Adults |
This is an example only. |
Preventive Care and Screening: Screening for High Blood Pressure and Follow-Up Documented |
This is an example only. |
Preventive Care and Screening: Tobacco Use: Screening and Cessation Intervention |
This is an example only. |
Preventive Care and Wellness All-Or-Nothing Composite |
This artifact is an example of an all-or-nothing composite measure that uses a mixture of single-rate or multi-rate component measures that have different measure bases. |
Preventive Care and Wellness Opportunity Composite |
This artifact is an example of an opportunity composite measure that uses a mixture of single-rate or multi-rate component measures that have different measure bases. |
Preventive Care and Wellness Patient-level Linear Composite |
This artifact is an example of a patient-level linear composite measure that uses a mixture of single-rate or multi-rate component measures that have different measure bases. |
Preventive Care and Wellness Weighted Composite |
This artifact is an example of a weighted composite measure that uses a mixture of single-rate or multi-rate component measures that have different measure bases. |
Risk Adjustment FHIR DSTU2 |
This example illustrates the use of risk adjustment data within a measure represented as a FHIR eCQM. |
Search Parameter - Library contained parameter name |
Example of a search parameter for a parameter name in a library |
Search Parameter - Library expansion identifier |
Example of a search paramter for an expansion identifier in a library |
Search Parameter - Valuset Keyword |
Example of a search parameter for a keyword in a value set |
Terminology FHIR |
This example illustrates the use of terminology within a measure represented as a FHIR eCQM. |