Quality Measure Implementation Guide
5.0.0 - STU5 United States of America flag

This page is part of the Quality Measure STU2 for FHIR R4 Implementation Guide (v5.0.0: STU5 (v5.0.0)) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version. For a full list of available versions, see the Directory of published versions

: Search Parameter - Library expansion identifier - JSON Representation

Draft as of 2023-05-25

Raw json | Download

{
  "resourceType" : "SearchParameter",
  "id" : "Library-expansion-identifier",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: SearchParameter Library-expansion-identifier</b></p><a name=\"Library-expansion-identifier\"> </a><a name=\"hcLibrary-expansion-identifier\"> </a><a name=\"Library-expansion-identifier-en-US\"> </a><h2>LibraryExpansionIdentifier</h2><p>Parameter <code>expansion-identifier</code>:<code>string</code></p><div><p>Parameters.parameter.valueUri within Library.contained</p>\n</div><table class=\"grid\"><tr><td>Resource</td><td><a href=\"http://hl7.org/fhir/R4/library.html\">Library</a></td></tr><tr><td>Expression</td><td><code>contained.ofType(Parameters).parameter.where(name='expansion').value</code></td></tr><tr><td>Processing Mode</td><td>Normal</td></tr><tr><td>Multiples</td><td><ul><li>multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true</li><li>multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true</li></ul></td></tr></table></div>"
  },
  "url" : "http://hl7.org/fhir/us/cqfmeasures/SearchParameter/Library-expansion-identifier",
  "version" : "5.0.0",
  "name" : "LibraryExpansionIdentifier",
  "status" : "draft",
  "experimental" : false,
  "date" : "2023-05-25T13:00:00-05:00",
  "publisher" : "HL7 International / Clinical Quality Information",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/cqi"
        }
      ]
    }
  ],
  "description" : "Parameters.parameter.valueUri within Library.contained",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "urn:iso:std:iso:3166",
          "code" : "US"
        }
      ]
    }
  ],
  "code" : "expansion-identifier",
  "base" : [
    "Library"
  ],
  "type" : "string",
  "expression" : "contained.ofType(Parameters).parameter.where(name='expansion').value",
  "xpathUsage" : "normal"
}