This page is part of the US Core (v6.1.0: STU6 Update) based on FHIR R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
<Observation xmlns="http://hl7.org/fhir">
<id value="satO2-fiO2"/>
<meta>
<profile
value="http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: Observation</b><a name="satO2-fiO2"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation "satO2-fiO2" </p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-us-core-pulse-oximetry.html">US Core Pulse Oximetry Profile</a></p></div><p><b>identifier</b>: id: o1223435-10</p><p><b>status</b>: final</p><p><b>category</b>: Vital Signs <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-observation-category.html">Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: Oxygen saturation in Arterial blood <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://loinc.org/">LOINC</a>#2708-6; <a href="https://loinc.org/">LOINC</a>#59408-5 "Oxygen saturation in Arterial blood by Pulse oximetry"; <a href="http://terminology.hl7.org/5.0.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a>#150456 "MDC_PULS_OXIM_SAT_O2")</span></p><p><b>subject</b>: <a href="Patient-example.html">Patient/example</a> " SHAW"</p><p><b>effective</b>: 2014-12-05 09:30:10+0100</p><p><b>value</b>: 95 %<span style="background: LightGoldenRodYellow"> (Details: UCUM code % = '%')</span></p><p><b>interpretation</b>: Normal (applies to non-numeric results) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.0.0/CodeSystem-v3-ObservationInterpretation.html">ObservationInterpretation</a>#N "Normal")</span></p><p><b>device</b>: <span>: Acme Pulse Oximeter 2000</span></p><h3>ReferenceRanges</h3><table class="grid"><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>90 %<span style="background: LightGoldenRodYellow"> (Details: UCUM code % = '%')</span></td><td>99 %<span style="background: LightGoldenRodYellow"> (Details: UCUM code % = '%')</span></td></tr></table><h3>Components</h3><table class="grid"><tr><td>-</td><td><b>Code</b></td><td><b>Value[x]</b></td></tr><tr><td>*</td><td>Inhaled oxygen flow rate <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://loinc.org/">LOINC</a>#3151-8)</span></td><td>6 liters/min<span style="background: LightGoldenRodYellow"> (Details: UCUM code L/min = 'L/min')</span></td></tr></table></div>
</text>
<identifier>
<system value="http://goodcare.org/observation/id"/>
<value value="o1223435-10"/>
</identifier>
<status value="final"/>
<category>
<coding>
<system
value="http://terminology.hl7.org/CodeSystem/observation-category"/>
<code value="vital-signs"/>
<display value="Vital Signs"/>
</coding>
<text value="Vital Signs"/>
</category>
<code>
<coding>
<system value="http://loinc.org"/>
<code value="2708-6"/>
<display value="Oxygen saturation in Arterial blood"/>
</coding>
<coding>
<system value="http://loinc.org"/>
<code value="59408-5"/>
<display value="Oxygen saturation in Arterial blood by Pulse oximetry"/>
</coding>
<coding>
<system value="urn:iso:std:iso:11073:10101"/>
<code value="150456"/>
<display value="MDC_PULS_OXIM_SAT_O2"/>
</coding>
</code>
<subject>
<reference value="Patient/example"/>
</subject>
<effectiveDateTime value="2014-12-05T09:30:10+01:00"/>
<valueQuantity>
<value value="95"/>
<unit value="%"/>
<system value="http://unitsofmeasure.org"/>
<code value="%"/>
</valueQuantity>
<interpretation>
<coding>
<system
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/>
<code value="N"/>
<display value="Normal"/>
</coding>
<text value="Normal (applies to non-numeric results)"/>
</interpretation>
<device>
<display value="Acme Pulse Oximeter 2000"/>
</device>
<referenceRange>
<low>
<value value="90"/>
<unit value="%"/>
<system value="http://unitsofmeasure.org"/>
<code value="%"/>
</low>
<high>
<value value="99"/>
<unit value="%"/>
<system value="http://unitsofmeasure.org"/>
<code value="%"/>
</high>
</referenceRange>
<component>
<code>
<coding>
<system value="http://loinc.org"/>
<code value="3151-8"/>
<display value="Inhaled oxygen flow rate"/>
</coding>
<text value="Inhaled oxygen flow rate"/>
</code>
<valueQuantity>
<value value="6"/>
<unit value="liters/min"/>
<system value="http://unitsofmeasure.org"/>
<code value="L/min"/>
</valueQuantity>
</component>
</Observation>
IG © 2023+ HL7 International - Cross-Group Projects. Package hl7.fhir.us.core#6.1.0 based on FHIR 4.0.1. Generated 2023-06-30
Links: Table of Contents |
QA Report
| Version History |
|
Propose a change