This page is part of the US Core (v3.1.1: STU3) based on FHIR R4. The current version which supercedes this version is 5.0.1. For a full list of available versions, see the Directory of published versions
JSON Format: Observation-satO2-fiO2
Download Raw json
{ "resourceType" : "Observation", "id" : "satO2-fiO2", "meta" : { "profile" : [ "http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry" ] }, "text" : { "status" : "generated", "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><p><b>id</b>: satO2-fiO2</p><p><b>meta</b>: </p><p><b>identifier</b>: id: o1223435-10</p><p></p><p><b>category</b>: <span title=\"Codes: {http://terminology.hl7.org/CodeSystem/observation-category vital-signs}\">Vital Signs</span></p><p><b>code</b>: <span title=\"Codes: {http://loinc.org 2708-6}, {http://loinc.org 59408-5}, {urn:iso:std:iso:11073:10101 150456}\">Oxygen saturation in Arterial blood</span></p><p><b>subject</b>: <a href=\"Patient-example.html\">Generated Summary: id: example; Medical Record Number: 1032702 (USUAL); active; Amy V. Shaw , Amy V. Baxter ; ph: 555-555-5555(HOME), amy.shaw@example.com; gender: female; birthDate: 1987-02-20</a></p><p><b>effective</b>: 05/12/2014 7:30:10 PM</p><p><b>value</b>: 95 %</p><p><b>interpretation</b>: <span title=\"Codes: {http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal (applies to non-numeric results)</span></p><p><b>device</b>: <span>Acme Pulse Oximeter 2000</span></p><h3>ReferenceRanges</h3><table class=\"grid\"><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>90 %</td><td>99 %</td></tr></table><h3>Components</h3><table class=\"grid\"><tr><td>-</td><td><b>Code</b></td><td><b>Value[x]</b></td></tr><tr><td>*</td><td><span title=\"Codes: {http://loinc.org 3151-8}\">Inhaled oxygen flow rate</span></td><td>6 liters/min</td></tr></table></div>" }, "identifier" : [ { "system" : "http://goodcare.org/observation/id", "value" : "o1223435-10" } ], "status" : "final", "category" : [ { "coding" : [ { "system" : "http://terminology.hl7.org/CodeSystem/observation-category", "code" : "vital-signs", "display" : "Vital Signs" } ], "text" : "Vital Signs" } ], "code" : { "coding" : [ { "system" : "http://loinc.org", "code" : "2708-6", "display" : "Oxygen saturation in Arterial blood" }, { "system" : "http://loinc.org", "code" : "59408-5", "display" : "Oxygen saturation in Arterial blood by Pulse oximetry" }, { "system" : "urn:iso:std:iso:11073:10101", "code" : "150456", "display" : "MDC_PULS_OXIM_SAT_O2" } ] }, "subject" : { "reference" : "Patient/example" }, "effectiveDateTime" : "2014-12-05T09:30:10+01:00", "valueQuantity" : { "value" : 95, "unit" : "%", "system" : "http://unitsofmeasure.org", "code" : "%" }, "interpretation" : [ { "coding" : [ { "system" : "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation", "code" : "N", "display" : "Normal" } ], "text" : "Normal (applies to non-numeric results)" } ], "device" : { "display" : "Acme Pulse Oximeter 2000" }, "referenceRange" : [ { "low" : { "value" : 90, "unit" : "%", "system" : "http://unitsofmeasure.org", "code" : "%" }, "high" : { "value" : 99, "unit" : "%", "system" : "http://unitsofmeasure.org", "code" : "%" } } ], "component" : [ { "code" : { "coding" : [ { "system" : "http://loinc.org", "code" : "3151-8", "display" : "Inhaled oxygen flow rate" } ], "text" : "Inhaled oxygen flow rate" }, "valueQuantity" : { "value" : 6, "unit" : "liters/min", "system" : "http://unitsofmeasure.org", "code" : "L/min" } } ] }