This page is part of the CodeX™ Radiation Therapy (v1.0.0: STU 1) based on FHIR R4. This is the current published version. For a full list of available versions, see the Directory of published versions
Official URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope | Version: 1.0.0 | |||
Draft as of 2023-07-28 | Computable Name: RadiotherapyEnergyOrIsotope |
The radiation energy used for radiotherapy. The energy spectrum is characterized by the maximum energy, the maximum accelaration voltage, or the used isotope.
Context of Use
This extension may be used on the following element(s):
Usage info
Usage:
Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.
This structure is derived from Extension
This structure is derived from Extension
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | 0..* | Extension | Radiotherapy Energy or Isotope | |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope" | |
Slices for value[x] | 1..1 | Value of extension Slice: Unordered, Open by type:$this | ||
valueCodeableConcept | CodeableConcept | |||
valueQuantity | Quantity(SimpleQuantity) | |||
value[x]:valueQuantity | 0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value.
For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. Binding: Radiotherapy Energy Unit Value Set (required) | |
value | 1..1 | decimal | Numerical value (with implicit precision) | |
system | 1..1 | uri | System that defines coded unit form | |
code | 1..1 | code | Coded form of the unit | |
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | The isotope used for radiotherapy. Binding: Radiotherapy Isotope Value Set (extensible) | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | 0..* | Extension | Radiotherapy Energy or Isotope | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope" | |
Slices for value[x] | 1..1 | Value of extension Slice: Unordered, Closed by type:$this | ||
valueCodeableConcept | CodeableConcept | |||
valueQuantity | Quantity(SimpleQuantity) | |||
value[x]:valueQuantity | C | 0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value.
For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. Binding: Radiotherapy Energy Unit Value Set (required) |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
value | Σ | 1..1 | decimal | Numerical value (with implicit precision) |
unit | Σ | 0..1 | string | Unit representation |
system | ΣC | 1..1 | uri | System that defines coded unit form |
code | Σ | 1..1 | code | Coded form of the unit |
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | The isotope used for radiotherapy. Binding: Radiotherapy Isotope Value Set (extensible) | |
Documentation for this format |
This structure is derived from Extension
Differential View
This structure is derived from Extension
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | 0..* | Extension | Radiotherapy Energy or Isotope | |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope" | |
Slices for value[x] | 1..1 | Value of extension Slice: Unordered, Open by type:$this | ||
valueCodeableConcept | CodeableConcept | |||
valueQuantity | Quantity(SimpleQuantity) | |||
value[x]:valueQuantity | 0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value.
For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. Binding: Radiotherapy Energy Unit Value Set (required) | |
value | 1..1 | decimal | Numerical value (with implicit precision) | |
system | 1..1 | uri | System that defines coded unit form | |
code | 1..1 | code | Coded form of the unit | |
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | The isotope used for radiotherapy. Binding: Radiotherapy Isotope Value Set (extensible) | |
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Extension | 0..* | Extension | Radiotherapy Energy or Isotope | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..0 | |||
url | 1..1 | uri | "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-energy-or-isotope" | |
Slices for value[x] | 1..1 | Value of extension Slice: Unordered, Closed by type:$this | ||
valueCodeableConcept | CodeableConcept | |||
valueQuantity | Quantity(SimpleQuantity) | |||
value[x]:valueQuantity | C | 0..1 | SimpleQuantity | The spectrum of radiation energy characterized by a maximum value.
For electrons, the maximum energy is given in MeV. For photons, the maximum acceleration voltage is given in MV or kV, although those are not units of energy. Binding: Radiotherapy Energy Unit Value Set (required) |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
value | Σ | 1..1 | decimal | Numerical value (with implicit precision) |
unit | Σ | 0..1 | string | Unit representation |
system | ΣC | 1..1 | uri | System that defines coded unit form |
code | Σ | 1..1 | code | Coded form of the unit |
value[x]:valueCodeableConcept | 0..1 | CodeableConcept | The isotope used for radiotherapy. Binding: Radiotherapy Isotope Value Set (extensible) | |
Documentation for this format |
Other representations of profile: CSV, Excel, Schematron
Path | Conformance | ValueSet |
Extension.value[x]:valueQuantity | required | RadiotherapyEnergyUnitVS |
Extension.value[x]:valueCodeableConcept | extensible | RadiotherapyIsotopeVS |