CodeX Radiation Therapy
1.0.0 - STU 1 United States of America flag

This page is part of the CodeX™ Radiation Therapy (v1.0.0: STU 1) based on FHIR R4. This is the current published version. For a full list of available versions, see the Directory of published versions

Extension: Image Guided Radiotherapy Modality

Official URL: http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality Version: 1.0.0
Draft as of 2023-07-28 Computable Name: ImageGuidedRadiotherapyModality

The modality and associated energy used for imaging in Image Guided Radiotherapy (IGRT)

Context of Use

This extension may be used on the following element(s):

  • Element ID ObservationDefinition
  • Element ID Procedure
  • Element ID ServiceRequest
  • Element ID Extension
  • Element ID Observation
  • Element ID ActivityDefinition
  • Element ID CarePlan
  • Element ID CareDefinition

Usage info

Usage:

Formal Views of Extension Content

Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.

This structure is derived from Extension

Summary

Complex Extension: The modality and associated energy used for imaging in Image Guided Radiotherapy (IGRT)

  • modality: CodeableConcept: An Extension
  • energy: CodeableConcept: An Extension

This structure is derived from Extension

NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension C0..*ExtensionImage Guided Radiotherapy Modality
IGRTEnergyAllowed: Energy is only allowed for X-Ray, Fluorograph, or CT Modalities.
... extension 1..*ExtensionExtension
... extension:modality S1..1ExtensionExtension
.... extension 0..0
.... url 1..1uri"modality"
.... value[x] 0..1CodeableConceptValue of extension
Binding: Image Guided Radiotherapy Modality Value Set (required)
... extension:energy S0..1ExtensionExtension
.... extension 0..0
.... url 1..1uri"energy"
.... value[x] 0..1CodeableConceptValue of extension
Binding: Image Guided Radiotherapy Energy Unit Value Set (required)
... value[x] 0..0

doco Documentation for this format
NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension C0..*ExtensionImage Guided Radiotherapy Modality
IGRTEnergyAllowed: Energy is only allowed for X-Ray, Fluorograph, or CT Modalities.
... id 0..1stringUnique id for inter-element referencing
... Slices for extension 1..*ExtensionExtension
Slice: Unordered, Open by value:url
... extension:modality S1..1ExtensionExtension
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..0
.... url 1..1uri"modality"
.... value[x] 0..1CodeableConceptValue of extension
Binding: Image Guided Radiotherapy Modality Value Set (required)
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..0
.... url 1..1uri"energy"
.... value[x] 0..1CodeableConceptValue of extension
Binding: Image Guided Radiotherapy Energy Unit Value Set (required)
... url 1..1uri"http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality"

doco Documentation for this format

This structure is derived from Extension

Summary

Complex Extension: The modality and associated energy used for imaging in Image Guided Radiotherapy (IGRT)

  • modality: CodeableConcept: An Extension
  • energy: CodeableConcept: An Extension

Differential View

This structure is derived from Extension

NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension C0..*ExtensionImage Guided Radiotherapy Modality
IGRTEnergyAllowed: Energy is only allowed for X-Ray, Fluorograph, or CT Modalities.
... extension 1..*ExtensionExtension
... extension:modality S1..1ExtensionExtension
.... extension 0..0
.... url 1..1uri"modality"
.... value[x] 0..1CodeableConceptValue of extension
Binding: Image Guided Radiotherapy Modality Value Set (required)
... extension:energy S0..1ExtensionExtension
.... extension 0..0
.... url 1..1uri"energy"
.... value[x] 0..1CodeableConceptValue of extension
Binding: Image Guided Radiotherapy Energy Unit Value Set (required)
... value[x] 0..0

doco Documentation for this format

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension C0..*ExtensionImage Guided Radiotherapy Modality
IGRTEnergyAllowed: Energy is only allowed for X-Ray, Fluorograph, or CT Modalities.
... id 0..1stringUnique id for inter-element referencing
... Slices for extension 1..*ExtensionExtension
Slice: Unordered, Open by value:url
... extension:modality S1..1ExtensionExtension
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..0
.... url 1..1uri"modality"
.... value[x] 0..1CodeableConceptValue of extension
Binding: Image Guided Radiotherapy Modality Value Set (required)
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..0
.... url 1..1uri"energy"
.... value[x] 0..1CodeableConceptValue of extension
Binding: Image Guided Radiotherapy Energy Unit Value Set (required)
... url 1..1uri"http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-image-guided-radiotherapy-modality"

doco Documentation for this format

 

Other representations of profile: CSV, Excel, Schematron

Terminology Bindings

PathConformanceValueSet
Extension.extension:modality.value[x]requiredImageGuidedRadiotherapyModalityVS
Extension.extension:energy.value[x]requiredImageGuidedRadiotherapyEnergyUnitVS