Resource Procedure "RadiotherapyCourseSummary-XRTS-04-22B-01-Breast-2P-3V" Version "8" Updated "2021-09-17 13:21:17+0100"

Profiles: Radiotherapy Course Summary, Radiotherapy Course Summary Profile

Procedure Intent Extension: Curative (SNOMED CT#373808002 "Curative - procedure intent")

Radiotherapy Modality And Technique Extension

url

Radiotherapy Modality Extension

value: External beam radiation therapy using photons (procedure) (SNOMED CT#1156506007)

url

Radiotherapy Technique Extension

value: Three dimensional external beam radiation therapy (procedure) (SNOMED CT#1162782007)

Respiratory Motion Management: Radiotherapy with free breathing (regime/therapy) (Requested SNOMED Codes Code System#721071000124104)

Free-Breathing Motion Management Technique: Radiotherapy with respiratory gating (regime/therapy) (Requested SNOMED Codes Code System#721061000124106)

Radiotherapy Modality And Technique Extension

url

Radiotherapy Modality Extension

value: External beam radiation therapy using electrons (procedure) (SNOMED CT#45643008)

url

Radiotherapy Technique Extension

value: Three dimensional external beam radiation therapy (procedure) (SNOMED CT#1162782007)

Radiotherapy Number of Sessions Extension: 8

Radiotherapy Dose Delivered To Volume Extension

url

volume

value: BodyStructure/RadiotherapyVolume-XRTS-04-22B-01-LeftBreast: Left Breast

url

Uniform Fractionation

value: true

url

totalDoseDelivered

value: 900 cGy (Details: UCUM code cGy = 'cGy')

url

fractionsDelivered

value: 3

Radiotherapy Dose Delivered To Volume Extension

url

volume

value: BodyStructure/RadiotherapyVolume-XRTS-04-22B-02-LeftBreastBoost: Left Breast Boost

url

Uniform Fractionation

value: false

url

totalDoseDelivered

value: 1700 cGy (Details: UCUM code cGy = 'cGy')

url

fractionsDelivered

value: 7

Radiotherapy Dose Delivered To Volume Extension

url

volume

value: BodyStructure/RadiotherapyVolume-XRTS-04-22B-03-RightBreast: Right Breast

url

Uniform Fractionation

value: true

url

totalDoseDelivered

value: 900 cGy (Details: UCUM code cGy = 'cGy')

url

fractionsDelivered

value: 3

identifier: http://varian.com/fhir/identifier/radiotherapyCourseId/C1_Both_Breast (use: usual), DUI/urn:oid:1.2.246.352.72.842418.2121.20150602151.04.01.22.1 (use: official)

basedOn: ServiceRequest/RadiotherapyPlannedCourse-XRTS-04-22B-01-Breast-2P-3V

status: completed

category: Radiotherapy (procedure) (Requested SNOMED Codes Code System#1287742003)

code: Radiotherapy course of treatment (SNOMED CT#1217123003)

subject: Patient/Patient-XRTS-04-22B " SISTER-22B"

performed: 2021-09-06 13:15:17+0100 --> 2021-09-17 13:21:17+0100

reasonCode: Primary malignant neoplasm of female left breast (disorder) (SNOMED CT#353431000119107)

bodySite: Breast structure (body structure) (SNOMED CT#76752008)