FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

4.3.1.195 Value Set http://hl7.org/fhir/ValueSet/detectedissue-mitigation-action

Clinical Decision Support Work Group Maturity Level: 1InformativeUse Context: Not Intended for Production use

This is a value set defined by the FHIR project.

Summary

Defining URL:http://hl7.org/fhir/ValueSet/detectedissue-mitigation-action
Name:Detected Issue Mitigation Action
Definition:Kinds of mitigating actions and observations that can be associated with a detected issue or contraindication, such as 'added concurrent therapy', 'prior therapy documented', etc.
Committee:Clinical Decision Support Work Group
OID:2.16.840.1.113883.4.642.3.195 (for OID based terminology systems)
Source ResourceXML / JSON

This value set is used in the following places:


This value set includes codes from the following code systems:

 

This expansion generated 19 Apr 2017


This value set contains 24 concepts

Expansion based on http://hl7.org/fhir/v3/ActCode version 2016-11-11

All codes from system http://hl7.org/fhir/v3/ActCode

CodeDisplayDefinition
_ActDetectedIssueManagementCodeActDetectedIssueManagementCodeCodes dealing with the management of Detected Issue observations
  _ActAdministrativeDetectedIssueManagementCodeActAdministrativeDetectedIssueManagementCodeCodes dealing with the management of Detected Issue observations for the administrative and patient administrative acts domains.
    _AuthorizationIssueManagementCodeAuthorization Issue Management CodeAuthorization Issue Management Code
      EMAUTHemergency authorization overrideUsed to temporarily override normal authorization rules to gain access to data in a case of emergency. Use of this override code will typically be monitored, and a procedure to verify its proper use may be triggered when used.
        21authorization confirmedDescription: Indicates that the permissions have been externally verified and the request should be processed.
  1Therapy AppropriateConfirmed drug therapy appropriate
    19Consulted SupplierConsulted other supplier/pharmacy, therapy confirmed
    2Assessed PatientAssessed patient, therapy is appropriate
    22appropriate indication or diagnosisDescription: The patient has the appropriate indication or diagnosis for the action to be taken.
    23prior therapy documentedDescription: It has been confirmed that the appropriate pre-requisite therapy has been tried.
    3Patient ExplanationPatient gave adequate explanation
    4Consulted Other SourceConsulted other supply source, therapy still appropriate
    5Consulted PrescriberConsulted prescriber, therapy confirmed
      6Prescriber Declined ChangeConsulted prescriber and recommended change, prescriber declined
    7Interacting Therapy No Longer Active/PlannedConcurrent therapy triggering alert is no longer on-going or planned
  14Supply AppropriateConfirmed supply action appropriate
    15ReplacementPatient's existing supply was lost/wasted
    16Vacation SupplySupply date is due to patient vacation
    17Weekend SupplySupply date is intended to carry patient over weekend
    18Leave of AbsenceSupply is intended for use during a leave of absence from an institution.
    20additional quantity on separate dispenseDescription: Supply is different than expected as an additional quantity has been supplied in a separate dispense.
  8Other Action TakenOrder is performed as issued, but other action taken to mitigate potential adverse effects
    10Provided Patient EducationProvided education or training to the patient on appropriate therapy use
    11Added Concurrent TherapyInstituted an additional therapy to mitigate potential negative effects
    12Temporarily Suspended Concurrent TherapySuspended existing therapy that triggered interaction for the duration of this therapy
    13Stopped Concurrent TherapyAborted existing therapy that triggered interaction.
    9Instituted Ongoing Monitoring ProgramArranged to monitor patient for adverse effects

 

See the full registry of value sets defined as part of FHIR.


Explanation of the columns that may appear on this page:

LevelA few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
SourceThe source of the definition of the code (when the value set draws in codes defined elsewhere)
CodeThe code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
DisplayThe display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
DefinitionAn explanation of the meaning of the concept
CommentsAdditional notes about how to use the code