This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Orders and Observations Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Real-world patient -base excess
@prefix fhir: <http://hl7.org/fhir/> . @prefix loinc: <http://loinc.org/owl#> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Observation/f002> a fhir:Observation; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "f002"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f002</p><p><b>identifier</b>: 6324 (OFFICIAL)</p><p><b>status</b>: final</p><p><b>code</b>: Base excess in Blood by calculation <span>(Details : {LOINC code '11555-0' = 'Base excess in Blood by calculation', given as 'Base excess in Blood by calculation'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>effective</b>: 02/04/2013 10:30:10 AM --> 05/04/2013 10:30:10 AM</p><p><b>issued</b>: 03/04/2013 3:30:10 PM</p><p><b>performer</b>: <a>A. Langeveld</a></p><p><b>value</b>: 12.6 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span></p><p><b>interpretation</b>: High <span>(Details : {http://hl7.org/fhir/v2/0078 code 'H' = 'High', given as 'High'})</span></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>7.1 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span></td><td>11.2 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span></td></tr></table></div>" ]; fhir:Observation.identifier [ fhir:index 0; fhir:Identifier.use [ fhir:value "official" ]; fhir:Identifier.system [ fhir:value "http://www.bmc.nl/zorgportal/identifiers/observations" ]; fhir:Identifier.value [ fhir:value "6324" ] ]; fhir:Observation.status [ fhir:value "final"]; fhir:Observation.code [ fhir:CodeableConcept.coding [ fhir:index 0; a loinc:11555-0; fhir:Coding.system [ fhir:value "http://loinc.org" ]; fhir:Coding.code [ fhir:value "11555-0" ]; fhir:Coding.display [ fhir:value "Base excess in Blood by calculation" ] ] ]; fhir:Observation.subject [ fhir:link <http://hl7.org/fhir/Patient/f001>; fhir:Reference.reference [ fhir:value "Patient/f001" ]; fhir:Reference.display [ fhir:value "P. van de Heuvel" ] ]; fhir:Observation.effectivePeriod [ fhir:Period.start [ fhir:value "2013-04-02T10:30:10+01:00"^^xsd:dateTime ]; fhir:Period.end [ fhir:value "2013-04-05T10:30:10+01:00"^^xsd:dateTime ] ]; fhir:Observation.issued [ fhir:value "2013-04-03T15:30:10+01:00"^^xsd:dateTime]; fhir:Observation.performer [ fhir:index 0; fhir:link <http://hl7.org/fhir/Practitioner/f005>; fhir:Reference.reference [ fhir:value "Practitioner/f005" ]; fhir:Reference.display [ fhir:value "A. Langeveld" ] ]; fhir:Observation.valueQuantity [ fhir:Quantity.value [ fhir:value "12.6"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "mmol/l" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mmol/L" ] ]; fhir:Observation.interpretation [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0078" ]; fhir:Coding.code [ fhir:value "H" ]; fhir:Coding.display [ fhir:value "High" ] ] ]; fhir:Observation.referenceRange [ fhir:index 0; fhir:Observation.referenceRange.low [ fhir:Quantity.value [ fhir:value "7.1"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "mmol/l" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mmol/L" ] ]; fhir:Observation.referenceRange.high [ fhir:Quantity.value [ fhir:value "11.2"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "mmol/l" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mmol/L" ] ] ] . <http://hl7.org/fhir/Patient/f001> a fhir:Patient . <http://hl7.org/fhir/Practitioner/f005> a fhir:Practitioner . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/Observation/f002.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://hl7.org/fhir/STU3/Observation/f002.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.