FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Diagnosticreport-example-f001-bloodexam.json

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Encounter, Patient, Practitioner

Raw JSON (canonical form)

Real-world patient example

{
  "resourceType": "DiagnosticReport",
  "id": "f001",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f001</p><p><b>contained</b>: </p><p><b>identifier</b>: nr1239044 (OFFICIAL)</p><p><b>basedOn</b>: id: req; L2381; status: active; intent: original-order; Complete blood count (hemogram) panel - Blood by Automated count <span>(Details : {LOINC code '58410-2' = 'Complete blood count (hemogram) panel - Blood by Automated count', given as 'Complete blood count (hemogram) panel - Blood by Automated count'})</span>; P. van den Heuvel; ????; Annotation: patient almost fainted during procedure</p><p><b>status</b>: final</p><p><b>category</b>: Haematology test <span>(Details : {SNOMED CT code '252275004' = 'Haematology test', given as 'Haematology test'}; {http://hl7.org/fhir/v2/0074 code 'HM' = 'Hematology)</span></p><p><b>code</b>: Complete blood count (hemogram) panel - Blood by Automated count <span>(Details : {LOINC code '58410-2' = 'Complete blood count (hemogram) panel - Blood by Automated count', given as 'Complete blood count (hemogram) panel - Blood by Automated count'})</span></p><p><b>subject</b>: <a>P. van den Heuvel</a></p><p><b>issued</b>: 15/05/2013 7:32:52 PM</p><h3>Performers</h3><table><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a>Burgers University Medical Centre</a></td></tr></table><p><b>result</b>: </p><ul><li><a>Observation/f001</a></li><li><a>Observation/f002</a></li><li><a>Observation/f003</a></li><li><a>Observation/f004</a></li><li><a>Observation/f005</a></li></ul><p><b>conclusion</b>: Core lab</p></div>"
  },
  "contained": [
    {
      "resourceType": "ProcedureRequest",
      "id": "req",
      "extension": [
        {
          "url": "http://example.org/bodysitecode",
          "valueCodeableConcept": {
            "coding": [
              {
                "system": "http://snomed.info/sct",
                "code": "14975008",
                "display": "Forearm structure"
              }
            ]
          }
        }
      ],
      "identifier": [
        {
          "system": "http://www.bmc.nl/zorgportal/identifiers/labresults",
          "value": "L2381"
        }
      ],
      "status": "active",
      "intent": "original-order",
      "code": {
        "coding": [
          {
            "system": "http://loinc.org",
            "code": "58410-2",
            "display": "Complete blood count (hemogram) panel - Blood by Automated count"
          }
        ]
      },
      "subject": {
        "reference": "Patient/f001",
        "display": "P. van den Heuvel"
      },
      "context": {
        "reference": "Encounter/f001"
      },
      "requester": {
        "agent": {
          "reference": "Practitioner/f001",
          "display": "E.van den Broek"
        }
      },
      "note": [
        {
          "text": "patient almost fainted during procedure"
        }
      ]
    }
  ],
  "identifier": [
    {
      "use": "official",
      "system": "http://www.bmc.nl/zorgportal/identifiers/reports",
      "value": "nr1239044"
    }
  ],
  "basedOn": [
    {
      "reference": "#req"
    }
  ],
  "status": "final",
  "category": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "252275004",
        "display": "Haematology test"
      },
      {
        "system": "http://hl7.org/fhir/v2/0074",
        "code": "HM"
      }
    ]
  },
  "code": {
    "coding": [
      {
        "system": "http://loinc.org",
        "code": "58410-2",
        "display": "Complete blood count (hemogram) panel - Blood by Automated count"
      }
    ]
  },
  "subject": {
    "reference": "Patient/f001",
    "display": "P. van den Heuvel"
  },
  "issued": "2013-05-15T19:32:52+01:00",
  "performer": [
    {
      "actor": {
        "reference": "Organization/f001",
        "display": "Burgers University Medical Centre"
      }
    }
  ],
  "result": [
    {
      "reference": "Observation/f001"
    },
    {
      "reference": "Observation/f002"
    },
    {
      "reference": "Observation/f003"
    },
    {
      "reference": "Observation/f004"
    },
    {
      "reference": "Observation/f005"
    }
  ],
  "conclusion": "Core lab"
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.