FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Bodysite-example-tumor.ttl

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Patient

Raw Turtle, JSON-LD

This example demonstrates using the bodysite resource to identify a specific tumor or lesion that will have multiple observations and/or procedures performed on it over time

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/BodySite/tumor> a fhir:BodySite;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "tumor"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: tumor</p><p><b>identifier</b>: 12345</p><p><b>code</b>: Splenic mass <span>(Details : {SNOMED CT code '4147007' = 'Mass', given as 'Mass (morphologic abnormality)'})</span></p><p><b>qualifier</b>: Splenic mass <span>(Details : {SNOMED CT code '78961009' = 'Spleen', given as 'Splenic structure (body structure)'})</span></p><p><b>description</b>: 7 cm maximum diameter</p><p><b>image</b>: </p><p><b>patient</b>: <a>Patient/example</a></p></div>"
  ];
  fhir:BodySite.identifier [
     fhir:index 0;
     fhir:Identifier.system [ fhir:value "http://goodhealth.org/bodysite/identifiers" ];
     fhir:Identifier.value [ fhir:value "12345" ]
  ];
  fhir:BodySite.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:4147007;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "4147007" ];
       fhir:Coding.display [ fhir:value "Mass (morphologic abnormality)" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Splenic mass" ]
  ];
  fhir:BodySite.qualifier [
     fhir:index 0;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:78961009;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "78961009" ];
       fhir:Coding.display [ fhir:value "Splenic structure (body structure)" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Splenic mass" ]
  ];
  fhir:BodySite.description [ fhir:value "7 cm maximum diameter"];
  fhir:BodySite.image [
     fhir:index 0;
     fhir:Attachment.contentType [ fhir:value "application/dicom" ];
     fhir:Attachment.url [ fhir:value "http://imaging.acme.com/wado/server?requestType=WADO&amp;wado_details" ]
  ];
  fhir:BodySite.patient [
     fhir:link <http://hl7.org/fhir/Patient/example>;
     fhir:Reference.reference [ fhir:value "Patient/example" ]
  ] .

<http://hl7.org/fhir/Patient/example> a fhir:Patient .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/BodySite/tumor.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://hl7.org/fhir/STU3/BodySite/tumor.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.