This page is part of the FHIR Specification (v4.0.1: R4 - Mixed Normative and STU) in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Devicemetric-example.json

Health Care Devices Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Not linked to any defined compartments

Raw JSON (canonical form + also see JSON Format Specification)

General DeviceMetric example

{
  "resourceType": "DeviceMetric",
  "id": "example",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>identifier</b>: 345675</p><p><b>type</b>: MDC_PULS_OXIM_SAT_O2 <span>(Details : {urn:iso:std:iso:11073:10101 code '150456' = '150456', given as 'MDC_PULS_OXIM_SAT_O2'})</span></p><p><b>unit</b>: MDC_DIM_PERCENT <span>(Details : {urn:iso:std:iso:11073:10101 code '262688' = '262688', given as 'MDC_DIM_PERCENT'})</span></p><p><b>source</b>: <a>Device/dev1</a></p><p><b>parent</b>: <a>DeviceDefinition/dc102</a></p><p><b>operationalStatus</b>: on</p><p><b>color</b>: blue</p><p><b>category</b>: measurement</p><p><b>measurementPeriod</b>: Do Once per 1 seconds</p><h3>Calibrations</h3><table><tr><td>-</td><td><b>Type</b></td><td><b>State</b></td><td><b>Time</b></td></tr><tr><td>*</td><td>two-point</td><td>calibrated</td><td>28/12/2016 9:03:04 AM</td></tr></table></div>"
  },
  "identifier": [
    {
      "system": "http://goodcare.org/devicemetric/id",
      "value": "345675"
    }
  ],
  "type": {
    "coding": [
      {
        "system": "urn:iso:std:iso:11073:10101",
        "code": "150456",
        "display": "MDC_PULS_OXIM_SAT_O2"
      }
    ]
  },
  "unit": {
    "coding": [
      {
        "system": "urn:iso:std:iso:11073:10101",
        "code": "262688",
        "display": "MDC_DIM_PERCENT"
      }
    ]
  },
  "source": {
    "reference": "Device/dev1"
  },
  "parent": {
    "reference": "DeviceDefinition/dc102"
  },
  "operationalStatus": "on",
  "color": "blue",
  "category": "measurement",
  "measurementPeriod": {
    "repeat": {
      "frequency": 1,
      "period": 1,
      "periodUnit": "s"
    }
  },
  "calibration": [
    {
      "type": "two-point",
      "state": "calibrated",
      "time": "2016-12-28T09:03:04-05:00"
    }
  ]
}