This page is part of the FHIR Specification (v4.3.0: R4B - STU). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Health Care Devices Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
General DeviceMetric example
{ "resourceType": "DeviceMetric", "id": "example", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative</b></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource "example" </p></div><p><b>identifier</b>: id: 345675</p><p><b>type</b>: MDC_PULS_OXIM_SAT_O2 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#150456)</span></p><p><b>unit</b>: MDC_DIM_PERCENT <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/3.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#262688)</span></p><p><b>source</b>: <a href=\"todo.html\">Device/dev1</a></p><p><b>parent</b>: <a href=\"todo.html\">DeviceDefinition/dc102</a></p><p><b>operationalStatus</b>: on</p><p><b>color</b>: blue</p><p><b>category</b>: measurement</p><p><b>measurementPeriod</b>: Do Once per 1 seconds</p><h3>Calibrations</h3><table class=\"grid\"><tr><td>-</td><td><b>Type</b></td><td><b>State</b></td><td><b>Time</b></td></tr><tr><td>*</td><td>two-point</td><td>calibrated</td><td>29/12/2016 1:03:04 AM</td></tr></table></div>" }, "identifier": [ { "system": "http://goodcare.org/devicemetric/id", "value": "345675" } ], "type": { "coding": [ { "system": "urn:iso:std:iso:11073:10101", "code": "150456", "display": "MDC_PULS_OXIM_SAT_O2" } ] }, "unit": { "coding": [ { "system": "urn:iso:std:iso:11073:10101", "code": "262688", "display": "MDC_DIM_PERCENT" } ] }, "source": { "reference": "Device/dev1" }, "parent": { "reference": "DeviceDefinition/dc102" }, "operationalStatus": "on", "color": "blue", "category": "measurement", "measurementPeriod": { "repeat": { "frequency": 1, "period": 1, "periodUnit": "s" } }, "calibration": [ { "type": "two-point", "state": "calibrated", "time": "2016-12-28T09:03:04-05:00" } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.