This page is part of the FHIR Specification (v4.0.1: R4 - Mixed Normative and STU) in it's permanent home (it will always be available at this URL). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5R4BR4
This Code system is used in the following value sets:
ValueSet: TemplateStatusCode (The status indicates the level of maturity of the design and may be used to manage the use of the design.)
ValueSet: TemplateStatusCode (The status indicates the level of maturity of the design and may be used to manage the use of the design.)
4.3.14.128.1 Content
4.3.14.128.2 TemplateStatusCode LifeCycle
Life cycle of the Status Code of a Template Design (Version)
This code system urn:oid:2.16.840.1.113883.3.1937.98.5.8 defines the following codes:
Code
Display
Definition
draft
Draft
Design is under development (nascent).
pending
Under pre-publication review
Design is completed and is being reviewed.
active
active
Design has been deemed fit for the intended purpose and is published by the governance group.
review
In Review
Design is active, but is under review. The review may result in a change to the design. The change may necessitate a new version to be created. This in turn may result in the prior version of the template to be retired. Alternatively, the review may result in a change to the design that does not require a new version to be created, or it may result in no change to the design at all.
cancelled
Cancelled
A drafted design is determined to be erroneous or not fit for intended purpose and is discontinued before ever being published in an active state.
rejected
Rejected
A previously drafted design is determined to be erroneous or not fit for intended purpose and is discontinued before ever being published for consideration in a pending state.
retired
retired
A previously active design is discontinued from use. It should no longer be used for future designs, but for historical purposes may be used to process data previously recorded using this design. A newer design may or may not exist. The design is published in the retired state.
terminated
Terminated
A design is determined to be erroneous or not fit for the intended purpose and should no longer be used, even for historical purposes. No new designs can be developed for this template. The associated template no longer needs to be published, but if published, is shown in the terminated state.
Explanation of the columns that may appear on this page:
Level
A few code lists that FHIR defines are hierarchical - each code is assigned a level. See Code System for further information.
Source
The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code
The code (used as the code in the resource instance). If the code is in italics, this indicates that the code is not selectable ('Abstract')
Display