Publish-box (todo)
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw XML (canonical form + also see XML Format Specification)
Bodimetrics (id = "Bodimetrics")
<?xml version="1.0" encoding="UTF-8"?> <Device xmlns="http://hl7.org/fhir"> <id value="Bodimetrics"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="Bodimetrics"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device "Bodimetrics" </p> </div> <p> <b> identifier</b> : System Identifier: 00-00-00-00-00-00-00-00, Bluetooth Address: 00-17-E9-54-C8-52</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> <td> <b> CarrierHRF</b> </td> <td> <b> EntryType</b> </td> </tr> <tr> <td> *</td> <td> 102698895442</td> <td> <a href="http://hl7.org/fhir/NamingSystem/gs1-di">http://hl7.org/fhir/NamingSystem/gs1-di</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> <td> (01)102698895442(21)1607124656</td> <td> unknown</td> </tr> </table> <p> <b> manufacturer</b> : BodiMetrics</p> <p> <b> serialNumber</b> : 1607124656</p> <h3> Names</h3> <table class="grid"><tr> <td> -</td> <td> <b> Value</b> </td> <td> <b> Type</b> </td> </tr> <tr> <td> *</td> <td> BM-88 4656</td> <td> user-friendly-name</td> </tr> </table> <p> <b> modelNumber</b> : 6611</p> <p> <b> type</b> : MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #65573 "MDC_MOC_VMS_MDS_SIMP")</span> </p> <blockquote> <p> <b> version</b> </p> <p> <b> type</b> : MDC_ID_PROD_SPEC_SW: Software revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #531975)</span> </p> <p> <b> value</b> : 020008</p> </blockquote> <blockquote> <p> <b> version</b> </p> <p> <b> type</b> : MDC_ID_PROD_SPEC_HW: Hardware revision <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #531974)</span> </p> <p> <b> value</b> : CC</p> </blockquote> <blockquote> <p> <b> conformsTo</b> </p> <p> <b> specification</b> : MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #528391)</span> </p> <p> <b> version</b> : 1</p> </blockquote> <blockquote> <p> <b> conformsTo</b> </p> <p> <b> specification</b> : MDC_DEV_SPEC_PROFILE_GENERIC: Generic 20601 device <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #528457)</span> </p> <p> <b> version</b> : 1</p> </blockquote> <blockquote> <p> <b> conformsTo</b> </p> <p> <b> specification</b> : MDC_DEV_SPEC_PROFILE_MIN_ECG: Electro cardiogram <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #528390)</span> </p> <p> <b> version</b> : 1</p> </blockquote> <blockquote> <p> <b> conformsTo</b> </p> <p> <b> specification</b> : MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #528388)</span> </p> <p> <b> version</b> : 1</p> </blockquote> <blockquote> <p> <b> conformsTo</b> </p> <p> <b> specification</b> : MDC_DEV_SPEC_PROFILE_TEMP: Thermometer <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #528392)</span> </p> <p> <b> version</b> : 1</p> </blockquote> <h3> Properties</h3> <table class="grid"><tr> <td> -</td> <td> <b> Type</b> </td> <td> <b> Value[x]</b> </td> </tr> <tr> <td> *</td> <td> MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #68220)</span> </td> <td> MDC_TIME_SYNC_NONE: No time synchronization <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html">ISO 11073-10101 Health informatics - Point-of-care</a> #532224)</span> </td> </tr> </table> </div> </text> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="SYSID"/> <display value="System Identifier"/> </coding> </type> <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> <value value="00-00-00-00-00-00-00-00"/> </identifier> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="BTMAC"/> <display value="Bluetooth Address"/> </coding> </type> <system value="http://hl7.org/fhir/sid/eui-48"/> <value value="00-17-E9-54-C8-52"/> </identifier> <udiCarrier> <deviceIdentifier value="102698895442"/> <issuer value="http://hl7.org/fhir/NamingSystem/gs1-di"/> <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> <carrierHRF value="(01)102698895442(21)1607124656"/> <entryType value="unknown"/> </udiCarrier> <manufacturer value="BodiMetrics"/> <serialNumber value="1607124656"/> <name> <value value="BM-88 4656"/> <type value="user-friendly-name"/> </name> <modelNumber value="6611"/> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="65573"/> <display value="MDC_MOC_VMS_MDS_SIMP"/> </coding> <text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/> </type> <version> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531975"/> </coding> <text value="MDC_ID_PROD_SPEC_SW: Software revision"/> </type> <value value="020008"/> </version> <version> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531974"/> </coding> <text value="MDC_ID_PROD_SPEC_HW: Hardware revision"/> </type> <value value="CC"/> </version> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528391"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528457"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_GENERIC: Generic 20601 device"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528390"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_MIN_ECG: Electro cardiogram"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528388"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528392"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_TEMP: Thermometer"/> </specification> <version value="1"/> </conformsTo> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="68220"/> </coding> <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> </type> <valueCodeableConcept> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532224"/> </coding> <text value="MDC_TIME_SYNC_NONE: No time synchronization"/> </valueCodeableConcept> </property> </Device>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0 generated on Sun, Mar 26, 2023 15:24+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4 |
Compare to R4B |
|
Propose a change