Publish-box (todo)
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw Turtle (+ also see Turtle/RDF Format Specification)
Bodimetrics
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- [a fhir:Device ; fhir:nodeRole fhir:treeRoot ; fhir:id [ fhir:v "Bodimetrics"] ; # fhir:text [ fhir:status [ fhir:v "generated" ] ; fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"Bodimetrics\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "Bodimetrics" </p></div><p><b>identifier</b>: System Identifier: 00-00-00-00-00-00-00-00, Bluetooth Address: 00-17-E9-54-C8-52</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td><td><b>CarrierHRF</b></td><td><b>EntryType</b></td></tr><tr><td>*</td><td>102698895442</td><td><a href=\"http://hl7.org/fhir/NamingSystem/gs1-di\">http://hl7.org/fhir/NamingSystem/gs1-di</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td><td>(01)102698895442(21)1607124656</td><td>unknown</td></tr></table><p><b>manufacturer</b>: BodiMetrics</p><p><b>serialNumber</b>: 1607124656</p><h3>Names</h3><table class=\"grid\"><tr><td>-</td><td><b>Value</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>BM-88 4656</td><td>user-friendly-name</td></tr></table><p><b>modelNumber</b>: 6611</p><p><b>type</b>: MDC_MOC_VMS_MDS_SIMP: Personal Health Device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#65573 "MDC_MOC_VMS_MDS_SIMP")</span></p><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_SW: Software revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531975)</span></p><p><b>value</b>: 020008</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: MDC_ID_PROD_SPEC_HW: Hardware revision <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#531974)</span></p><p><b>value</b>: CC</p></blockquote><blockquote><p><b>conformsTo</b></p><p><b>specification</b>: MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528391)</span></p><p><b>version</b>: 1</p></blockquote><blockquote><p><b>conformsTo</b></p><p><b>specification</b>: MDC_DEV_SPEC_PROFILE_GENERIC: Generic 20601 device <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528457)</span></p><p><b>version</b>: 1</p></blockquote><blockquote><p><b>conformsTo</b></p><p><b>specification</b>: MDC_DEV_SPEC_PROFILE_MIN_ECG: Electro cardiogram <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528390)</span></p><p><b>version</b>: 1</p></blockquote><blockquote><p><b>conformsTo</b></p><p><b>specification</b>: MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528388)</span></p><p><b>version</b>: 1</p></blockquote><blockquote><p><b>conformsTo</b></p><p><b>specification</b>: MDC_DEV_SPEC_PROFILE_TEMP: Thermometer <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#528392)</span></p><p><b>version</b>: 1</p></blockquote><h3>Properties</h3><table class=\"grid\"><tr><td>-</td><td><b>Type</b></td><td><b>Value[x]</b></td></tr><tr><td>*</td><td>MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#68220)</span></td><td>MDC_TIME_SYNC_NONE: No time synchronization <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-mdc.html\">ISO 11073-10101 Health informatics - Point-of-care</a>#532224)</span></td></tr></table></div>" ] ; # fhir:identifier ( [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ; fhir:code [ fhir:v "SYSID" ] ; fhir:display [ fhir:v "System Identifier" ] ] ) ] ; fhir:system [ fhir:v "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"^^xsd:anyURI ] ; fhir:value [ fhir:v "00-00-00-00-00-00-00-00" ] ] [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"^^xsd:anyURI ] ; fhir:code [ fhir:v "BTMAC" ] ; fhir:display [ fhir:v "Bluetooth Address" ] ] ) ] ; fhir:system [ fhir:v "http://hl7.org/fhir/sid/eui-48"^^xsd:anyURI ] ; fhir:value [ fhir:v "00-17-E9-54-C8-52" ] ] ) ; # fhir:udiCarrier ( [ fhir:deviceIdentifier [ fhir:v "102698895442" ] ; fhir:issuer [ fhir:v "http://hl7.org/fhir/NamingSystem/gs1-di"^^xsd:anyURI ] ; fhir:jurisdiction [ fhir:v "http://hl7.org/fhir/NamingSystem/fda-udi"^^xsd:anyURI ] ; fhir:carrierHRF [ fhir:v "(01)102698895442(21)1607124656" ] ; fhir:entryType [ fhir:v "unknown" ] ] ) ; # fhir:manufacturer [ fhir:v "BodiMetrics"] ; # fhir:serialNumber [ fhir:v "1607124656"] ; # fhir:name ( [ fhir:value [ fhir:v "BM-88 4656" ] ; fhir:type [ fhir:v "user-friendly-name" ] ] ) ; # fhir:modelNumber [ fhir:v "6611"] ; # fhir:type ( [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "65573" ] ; fhir:display [ fhir:v "MDC_MOC_VMS_MDS_SIMP" ] ] ) ; fhir:text [ fhir:v "MDC_MOC_VMS_MDS_SIMP: Personal Health Device" ] ] ) ; # fhir:version ( [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "531975" ] ] ) ; fhir:text [ fhir:v "MDC_ID_PROD_SPEC_SW: Software revision" ] ] ; fhir:value [ fhir:v "020008" ] ] [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "531974" ] ] ) ; fhir:text [ fhir:v "MDC_ID_PROD_SPEC_HW: Hardware revision" ] ] ; fhir:value [ fhir:v "CC" ] ] ) ; # fhir:conformsTo ( [ fhir:specification [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "528391" ] ] ) ; fhir:text [ fhir:v "MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter" ] ] ; fhir:version [ fhir:v "1" ] ] [ fhir:specification [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "528457" ] ] ) ; fhir:text [ fhir:v "MDC_DEV_SPEC_PROFILE_GENERIC: Generic 20601 device" ] ] ; fhir:version [ fhir:v "1" ] ] [ fhir:specification [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "528390" ] ] ) ; fhir:text [ fhir:v "MDC_DEV_SPEC_PROFILE_MIN_ECG: Electro cardiogram" ] ] ; fhir:version [ fhir:v "1" ] ] [ fhir:specification [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "528388" ] ] ) ; fhir:text [ fhir:v "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter" ] ] ; fhir:version [ fhir:v "1" ] ] [ fhir:specification [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "528392" ] ] ) ; fhir:text [ fhir:v "MDC_DEV_SPEC_PROFILE_TEMP: Thermometer" ] ] ; fhir:version [ fhir:v "1" ] ] ) ; # fhir:property ( [ fhir:type [ fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "68220" ] ] ) ; fhir:text [ fhir:v "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol" ] ] ; fhir:value [ a fhir:CodeableConcept ; fhir:coding ( [ fhir:system [ fhir:v "urn:iso:std:iso:11073:10101"^^xsd:anyURI ] ; fhir:code [ fhir:v "532224" ] ] ) ; fhir:text [ fhir:v "MDC_TIME_SYNC_NONE: No time synchronization" ] ] ] )] . # # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0 generated on Sun, Mar 26, 2023 15:24+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4 |
Compare to R4B |
|
Propose a change