FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3

V2-0914.cs.xml

Vocabulary Work GroupMaturity Level: N/ABallot Status: Informative

Raw XML (canonical form)

FHIR Value set/code system definition for HL7 v2 table 0914 ( Root Cause)

<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="v2-0914"/> 
  <meta> 
    <profile value="http://hl7.org/fhir/StructureDefinition/shareablecodesystem"/> 
  </meta> 
  <text> 
    <status value="additional"/> 
    <div xmlns="http://www.w3.org/1999/xhtml">
      <p> Root Cause</p> 

      <table class="grid">
        <tr> 
          <td> 
            <b> Code</b> 
          </td> 
          <td> 
            <b> Description</b> 
          </td> 
          <td> 
            <b> Comment</b> 
          </td> 
          <td> 
            <b> Version</b> 
          </td> 
        </tr> 
        <tr> 
          <td> AP
            <a name="AP"> </a> 
          </td> 
          <td> Analysis Process</td> 
          <td> Enter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents,
               calibrators, QC material) • Equipment or instrumentation failure</td> 
          <td> added v2.8</td> 
        </tr> 
        <tr> 
          <td> IM
            <a name="IM"> </a> 
          </td> 
          <td> Information Management</td> 
          <td> Enter (IM) when INFORMATION MANAGEMENT is the reason due to:&lt;p&gt;• Database or Programming
               issues&lt;p&gt;• Overriding of test results&lt;p&gt;• Inaccurate calculations&lt;p&gt;•
               Inaccurate flagging, reference ranges, units of measure&lt;p&gt;• Incomplete/inaccurate
               tran</td> 
          <td> added v2.8</td> 
        </tr> 
        <tr> 
          <td> L
            <a name="L"> </a> 
          </td> 
          <td> Laboratory</td> 
          <td> Enter (L) when LABORATORY is the reason due to:&lt;p&gt;• Data Entry error&lt;p&gt;•
               Testing/Technical error&lt;p&gt;• Repeat testing causing change to test result</td> 
          <td> added v2.8</td> 
        </tr> 
        <tr> 
          <td> NA
            <a name="NA"> </a> 
          </td> 
          <td> Not Applicable</td> 
          <td> Enter (NA) when NOT-APPLICABLE is the reason due to:&lt;p&gt;• If no revisions performed
               or&lt;p&gt;• unable to determine reason for revision&lt;p&gt;Note:  Do not use NA if
               result code status is not corrected (revised) or if a preliminary release of results with
               a cor</td> 
          <td> added v2.8</td> 
        </tr> 
        <tr> 
          <td> PD
            <a name="PD"> </a> 
          </td> 
          <td> Placer Data</td> 
          <td> Enter (PD) when new or changed PLACER DATA information is the reason due to:&lt;p&gt;•
               Changed patient demographics or&lt;p&gt;• Result code data provided by the client on
               the requisition or specimen manifest that will be entered during order entry (i.e. Previous</td> 
          <td> added v2.8</td> 
        </tr> 
      </table> 

    </div> 
  </text> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-ballot-status">
    <valueString value="External"/> 
  </extension> 
  <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="0"/> 
  </extension> 
  <url value="http://hl7.org/fhir/v2/0914"/> 
  <identifier> 
    <system value="urn:ietf:rfc:3986"/> 
    <value value="urn:oid:2.16.840.1.113883.18.421"/> 
  </identifier> 
  <version value="2.8.2"/> 
  <name value="v2 Root Cause"/> 
  <status value="active"/> 
  <experimental value="false"/> 
  <publisher value="HL7, Inc"/> 
  <contact> 
    <telecom> 
      <system value="url"/> 
      <value value="http://hl7.org"/> 
    </telecom> 
  </contact> 
  <description value="FHIR Value set/code system definition for HL7 v2 table 0914 ( Root Cause)"/> 
  <caseSensitive value="false"/> 
  <valueSet value="http://hl7.org/fhir/ValueSet/v2-0914"/> 
  <content value="complete"/> 
  <concept> 
    <extension url="http://hl7.org/fhir/StructureDefinition/codesystem-comments">
      <valueString value="Enter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents,
         calibrators, QC material) • Equipment or instrumentation failure"/> 
    </extension> 
    <code value="AP"/> 
    <display value="Analysis Process"/> 
  </concept> 
  <concept> 
    <extension url="http://hl7.org/fhir/StructureDefinition/codesystem-comments">
      <valueString value="Enter (IM) when INFORMATION MANAGEMENT is the reason due to:&lt;p&gt;• Database or Programming
         issues&lt;p&gt;• Overriding of test results&lt;p&gt;• Inaccurate calculations&lt;p&gt;•
         Inaccurate flagging, reference ranges, units of measure&lt;p&gt;• Incomplete/inaccurate
         tran"/> 
    </extension> 
    <code value="IM"/> 
    <display value="Information Management"/> 
  </concept> 
  <concept> 
    <extension url="http://hl7.org/fhir/StructureDefinition/codesystem-comments">
      <valueString value="Enter (L) when LABORATORY is the reason due to:&lt;p&gt;• Data Entry error&lt;p&gt;•
         Testing/Technical error&lt;p&gt;• Repeat testing causing change to test result"/> 
    </extension> 
    <code value="L"/> 
    <display value="Laboratory"/> 
  </concept> 
  <concept> 
    <extension url="http://hl7.org/fhir/StructureDefinition/codesystem-comments">
      <valueString value="Enter (NA) when NOT-APPLICABLE is the reason due to:&lt;p&gt;• If no revisions performed
         or&lt;p&gt;• unable to determine reason for revision&lt;p&gt;Note:  Do not use NA if
         result code status is not corrected (revised) or if a preliminary release of results with
         a cor"/> 
    </extension> 
    <code value="NA"/> 
    <display value="Not Applicable"/> 
  </concept> 
  <concept> 
    <extension url="http://hl7.org/fhir/StructureDefinition/codesystem-comments">
      <valueString value="Enter (PD) when new or changed PLACER DATA information is the reason due to:&lt;p&gt;•
         Changed patient demographics or&lt;p&gt;• Result code data provided by the client on
         the requisition or specimen manifest that will be entered during order entry (i.e. Previous"/> 
    </extension> 
    <code value="PD"/> 
    <display value="Placer Data"/> 
  </concept> 
</CodeSystem> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.