FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3

V2-0914.cs.json

Vocabulary Work GroupMaturity Level: N/ABallot Status: Informative

Raw JSON (canonical form)

FHIR Value set/code system definition for HL7 v2 table 0914 ( Root Cause)

{
  "resourceType": "CodeSystem",
  "id": "v2-0914",
  "meta": {
    "profile": [
      "http://hl7.org/fhir/StructureDefinition/shareablecodesystem"
    ]
  },
  "text": {
    "status": "additional",
    "div": "<div>!-- Snipped for Brevity --></div>"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-ballot-status",
      "valueString": "External"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0
    }
  ],
  "url": "http://hl7.org/fhir/v2/0914",
  "identifier": {
    "system": "urn:ietf:rfc:3986",
    "value": "urn:oid:2.16.840.1.113883.18.421"
  },
  "version": "2.8.2",
  "name": "v2 Root Cause",
  "status": "active",
  "experimental": false,
  "publisher": "HL7, Inc",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://hl7.org"
        }
      ]
    }
  ],
  "description": "FHIR Value set/code system definition for HL7 v2 table 0914 ( Root Cause)",
  "caseSensitive": false,
  "valueSet": "http://hl7.org/fhir/ValueSet/v2-0914",
  "content": "complete",
  "concept": [
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
          "valueString": "Enter (AP) when ANALYSIS PROCESS is the reason due to: • Product or supply failure (reagents, calibrators, QC material) • Equipment or instrumentation failure"
        }
      ],
      "code": "AP",
      "display": "Analysis Process"
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
          "valueString": "Enter (IM) when INFORMATION MANAGEMENT is the reason due to:<p>• Database or Programming issues<p>• Overriding of test results<p>• Inaccurate calculations<p>• Inaccurate flagging, reference ranges, units of measure<p>• Incomplete/inaccurate tran"
        }
      ],
      "code": "IM",
      "display": "Information Management"
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
          "valueString": "Enter (L) when LABORATORY is the reason due to:<p>• Data Entry error<p>• Testing/Technical error<p>• Repeat testing causing change to test result"
        }
      ],
      "code": "L",
      "display": "Laboratory"
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
          "valueString": "Enter (NA) when NOT-APPLICABLE is the reason due to:<p>• If no revisions performed or<p>• unable to determine reason for revision<p>Note:  Do not use NA if result code status is not corrected (revised) or if a preliminary release of results with a cor"
        }
      ],
      "code": "NA",
      "display": "Not Applicable"
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
          "valueString": "Enter (PD) when new or changed PLACER DATA information is the reason due to:<p>• Changed patient demographics or<p>• Result code data provided by the client on the requisition or specimen manifest that will be entered during order entry (i.e. Previous"
        }
      ],
      "code": "PD",
      "display": "Placer Data"
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.