FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Medicationrequest0320.xml

Pharmacy Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Encounter, Patient, Practitioner

Raw XML (canonical form)

Jump past Narrative

Order for Subcutaneous injection - Insulin - Lantus - completed, with reason code and dispense request (id = "medrx0320")

<MedicationRequest xmlns="http://hl7.org/fhir">
  <id value="medrx0320"/> 
    <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : medrx0320</p> <p> <b> identifier</b> : 12345689 (OFFICIAL)</p> <p> <b> status</b> : completed</p> <p> <b> intent</b> : order</p> <p> <b> medication</b> : Lantus 100 unit/ml injectable solution <span> (Details : {RxNorm code '285018' = '285018', given as 'Lantus 100 unit/ml injectable solution'})</span> </p> <p> <b> subject</b> : <a> Donald Duck</a> </p> <p> <b> authoredOn</b> : 15/01/2015</p> <h3> Requesters</h3> <table> <tr> <td> -</td> <td> <b> Agent</b> </td> <td> <b> OnBehalfOf</b> </td> </tr> <tr> <td> *</td> <td> <a> Patrick Pump</a> </td> <td> <a> Organization/f002</a> </td> </tr> </table> <p> <b> reasonCode</b> : On subcutaneous insulin for diabetes mellitus (finding) <span> (Details : {SNOMED CT code '473189005' = 'On subcutaneous insulin for diabetes mellitus',
           given as 'On subcutaneous insulin for diabetes mellitus (finding)'})</span> </p> <p> <b> dosageInstruction</b> : </p> <h3> DispenseRequests</h3> <table> <tr> <td> -</td> <td> <b> ValidityPeriod</b> </td> <td> <b> NumberOfRepeatsAllowed</b> </td> <td> <b> Quantity</b> </td> <td> <b> ExpectedSupplyDuration</b> </td> </tr> <tr> <td> *</td> <td> 15/01/2015 --&gt; 15/01/2016</td> <td> 6</td> <td> 10 mL<span>  (Details: UCUM code mL = 'mL')</span> </td> <td> 30 days<span>  (Details: UCUM code d = 'd')</span> </td> </tr> </table> </div> </text> <identifier> 
        <use value="official"/> 
        <system value="http://www.bmc.nl/portal/prescriptions"/> 
        <value value="12345689"/> 
    </identifier> 
    <status value="completed"/> 
    <intent value="order">
    </intent> 
    <medicationCodeableConcept> 
        <coding> 
            <system value="http://www.nlm.nih.gov/research/umls/rxnorm"/> 
            <code value="285018"/> 
            <display value="Lantus 100 unit/ml injectable solution"/> 
        </coding> 
    </medicationCodeableConcept> 
    <subject>  <!--    Linked to the resource patient who needs the medication    -->
        <reference value="Patient/pat1"/> 
        <display value="Donald Duck"/>          
    </subject> 
    <authoredOn value="2015-01-15"/> 
    <requester> 
        <agent> 
            <reference value="Practitioner/f007"/> 
            <display value="Patrick Pump"/> 
        </agent> 
        <onBehalfOf> 
            <reference value="Organization/f002"/> 
        </onBehalfOf> 
    </requester> 
    <reasonCode> 
        <coding> 
            <system value="http://snomed.info/sct"/> 
            <code value="473189005"/> 
            <display value="On subcutaneous insulin for diabetes mellitus (finding)"/> 
        </coding> 
    </reasonCode> 
    <dosageInstruction> 
        <sequence value="1"/> 
        <text value="20 Units SC three times daily"/> 
        <timing> 
            <repeat> 
                <frequency value="3"/> 
                <period value="1"/> 
                <periodUnit value="d"/> 
            </repeat> 
        </timing> 
        <route> 
            <coding> 
                <system value="http://snomed.info/sct"/> 
                <code value="263887005"/> 
                <display value="Subcutaneous (qualifier value)"/> 
            </coding> 
        </route> 
        <doseQuantity> 
            <value value="20"/> 
            <unit value="U"/> 
            <system value="http://unitsofmeasure.org"/> 
            <code value="U"/> 
        </doseQuantity> 
    </dosageInstruction>  
    <dispenseRequest> 
        <validityPeriod> 
            <start value="2015-01-15"/> 
            <end value="2016-01-15"/>  
        </validityPeriod> 
        <numberOfRepeatsAllowed value="6"/> 
        <quantity> 
            <value value="10"/> 
            <unit value="mL"/> 
            <system value="http://unitsofmeasure.org"/> 
            <code value="mL"/>  
        </quantity> 
        <expectedSupplyDuration> 
            <value value="30"/> 
            <unit value="days"/> 
            <system value="http://unitsofmeasure.org"/> 
            <code value="d"/> 
        </expectedSupplyDuration> 
    </dispenseRequest> 
</MedicationRequest> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.