IV Chemotherapy Example - Manufactured Product - Adcetris
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
<http://hl7.org/fhir/Medication/med0306> a fhir:Medication;
fhir:nodeRole fhir:treeRoot;
fhir:Resource.id [ fhir:value "med0306"];
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "generated" ];
fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: med0306</p><p><b>contained</b>: </p><p><b>code</b>: Adcetris <span>(Details : {http://hl7.org/fhir/sid/ndc code '51144-050-01' = '51144-050-01', given as 'Adcetris'})</span></p><p><b>isBrand</b>: true</p><p><b>manufacturer</b>: id: org3; name: Seattle Genetics Inc</p><p><b>form</b>: Lyophilized powder for injectable solution (qualifier value) <span>(Details : {SNOMED CT code '421637006' = 'Lyophilised powder for injectable solution', given as 'Lyophilized powder for injectable solution (qualifier value) '})</span></p><blockquote><p><b>package</b></p><h3>Batches</h3><table><tr><td>-</td><td><b>LotNumber</b></td><td><b>ExpirationDate</b></td></tr><tr><td>*</td><td>12345</td><td>31/10/2019</td></tr></table></blockquote></div>"
];
fhir:DomainResource.contained [
a fhir:Organization;
fhir:index 0;
fhir:Resource.id [ fhir:value "org3" ];
fhir:Organization.name [ fhir:value "Seattle Genetics Inc" ]
];
fhir:Medication.code [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/sid/ndc" ];
fhir:Coding.code [ fhir:value "51144-050-01" ];
fhir:Coding.display [ fhir:value "Adcetris" ]
]
];
fhir:Medication.isBrand [ fhir:value "true"^^xsd:boolean];
fhir:Medication.manufacturer [
fhir:Reference.reference [ fhir:value "#org3" ]
];
fhir:Medication.form [
fhir:CodeableConcept.coding [
fhir:index 0;
a sct:421637006;
fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
fhir:Coding.code [ fhir:value "421637006" ];
fhir:Coding.display [ fhir:value "Lyophilized powder for injectable solution (qualifier value) " ]
]
];
fhir:Medication.package [
fhir:Medication.package.batch [
fhir:index 0;
fhir:Medication.package.batch.lotNumber [ fhir:value "12345" ];
fhir:Medication.package.batch.expirationDate [ fhir:value "2019-10-31"^^xsd:date ]
]
] .
# - ontology header ------------------------------------------------------------
<http://hl7.org/fhir/Medication/med0306.ttl> a owl:Ontology;
owl:imports fhir:fhir.ttl;
owl:versionIRI <http://hl7.org/fhir/STU3/Medication/med0306.ttl> .
# -------------------------------------------------------------------------------------