FHIR Release 3 (STU)

This page is part of the FHIR Specification (v3.0.2: STU 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Audit-event-example-vread.json

Security Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Patient, Practitioner

Raw JSON (canonical form)

RESTful vread Operation

{
  "resourceType": "AuditEvent",
  "id": "example-rest",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example-rest</p><p><b>type</b>: Restful Operation (Details: http://hl7.org/fhir/audit-event-type code rest = 'RESTful Operation', stated as 'Restful Operation')</p><p><b>subtype</b>: vread (Details: http://hl7.org/fhir/restful-interaction code vread = 'vread', stated as 'vread')</p><p><b>action</b>: R</p><p><b>recorded</b>: 20/06/2013 11:42:24 PM</p><p><b>outcome</b>: 0</p><blockquote><p><b>agent</b></p><p><b>userId</b>: 95</p><p><b>altId</b>: 601847123</p><p><b>name</b>: Grahame Grieve</p><p><b>requestor</b>: true</p></blockquote><blockquote><p><b>agent</b></p><p><b>role</b>: Source Role ID <span>(Details : {DICOM code '110153' = 'Source Role ID', given as 'Source Role ID'})</span></p><p><b>userId</b>: 2.16.840.1.113883.4.2|2.16.840.1.113883.4.2</p><p><b>altId</b>: 6580</p><p><b>requestor</b>: false</p><h3>Networks</h3><table><tr><td>-</td><td><b>Address</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>Workstation1.ehr.familyclinic.com</td><td>1</td></tr></table></blockquote><h3>Sources</h3><table><tr><td>-</td><td><b>Site</b></td><td><b>Identifier</b></td><td><b>Type</b></td></tr><tr><td>*</td><td>Cloud</td><td>hl7connect.healthintersections.com.au</td><td>Web Server (Details: http://hl7.org/fhir/security-source-type code 3 = 'Web Server', stated as 'Web Server')</td></tr></table><h3>Entities</h3><table><tr><td>-</td><td><b>Reference</b></td><td><b>Type</b></td><td><b>Lifecycle</b></td></tr><tr><td>*</td><td><a>Patient/example/_history/1</a></td><td>System Object (Details: http://hl7.org/fhir/object-type code 2 = '2', stated as 'System Object')</td><td>Access / Use (Details: http://hl7.org/fhir/dicom-audit-lifecycle code 6 = 'Access / Use', stated as 'Access / Use')</td></tr></table></div>"
  },
  "type": {
    "system": "http://hl7.org/fhir/audit-event-type",
    "code": "rest",
    "display": "Restful Operation"
  },
  "subtype": [
    {
      "system": "http://hl7.org/fhir/restful-interaction",
      "code": "vread",
      "display": "vread"
    }
  ],
  "action": "R",
  "recorded": "2013-06-20T23:42:24Z",
  "outcome": "0",
  "agent": [
    {
      "userId": {
        "value": "95"
      },
      "altId": "601847123",
      "name": "Grahame Grieve",
      "requestor": true
    },
    {
      "role": [
        {
          "coding": [
            {
              "system": "http://dicom.nema.org/resources/ontology/DCM",
              "code": "110153",
              "display": "Source Role ID"
            }
          ]
        }
      ],
      "userId": {
        "value": "2.16.840.1.113883.4.2|2.16.840.1.113883.4.2"
      },
      "altId": "6580",
      "requestor": false,
      "network": {
        "address": "Workstation1.ehr.familyclinic.com",
        "type": "1"
      }
    }
  ],
  "source": {
    "site": "Cloud",
    "identifier": {
      "value": "hl7connect.healthintersections.com.au"
    },
    "type": [
      {
        "system": "http://hl7.org/fhir/security-source-type",
        "code": "3",
        "display": "Web Server"
      }
    ]
  },
  "entity": [
    {
      "reference": {
        "reference": "Patient/example/_history/1"
      },
      "type": {
        "system": "http://hl7.org/fhir/object-type",
        "code": "2",
        "display": "System Object"
      },
      "lifecycle": {
        "system": "http://hl7.org/fhir/dicom-audit-lifecycle",
        "code": "6",
        "display": "Access / Use"
      }
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.