This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version in it's permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw XML (canonical form + also see XML Format Specification)
Example definition of venous blood specimen. (id = "7")
<?xml version="1.0" encoding="UTF-8"?> <SpecimenDefinition xmlns="http://hl7.org/fhir"> <id value="7"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: SpecimenDefinition</b> <a name="7"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource SpecimenDefinition "7" </p> </div> <p> <b> url</b> : <code> http://example-lab.com/specdef/123455</code> </p> <p> <b> identifier</b> : id: 123455</p> <p> <b> title</b> : Venous blood specimen</p> <p> <b> status</b> : active</p> <p> <b> experimental</b> : true</p> <p> <b> typeCollected</b> : Venous blood specimen (specimen) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #122555007)</span> </p> <p> <b> patientPreparation</b> : no strict fasting <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span> </p> <blockquote> <p> <b> typeTested</b> </p> <p> <b> isDerived</b> : true</p> <p> <b> type</b> : Serum specimen (specimen) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #119364003)</span> </p> <p> <b> preference</b> : preferred</p> <h3> Containers</h3> <table class="grid"><tr> <td> -</td> <td> <b> Material</b> </td> <td> <b> Type</b> </td> <td> <b> Cap</b> </td> <td> <b> MinimumVolume[x]</b> </td> </tr> <tr> <td> *</td> <td> glass <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span> </td> <td> Evacuated blood collection tube with thrombin and clot activator and gel separator <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #702281005)</span> </td> <td> yellow cap <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (CodeSystem-container-cap.html#yellow)</span> </td> <td> 2 ml<span style="background: LightGoldenRodYellow"> (Details: UCUM code mL = 'mL')</span> </td> </tr> </table> <blockquote> <p> <b> handling</b> </p> <p> <b> temperatureQualifier</b> : room temperature <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ([not stated]#room)</span> </p> <p> <b> temperatureRange</b> : 15-25 °C</p> <h3> MaxDurations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Value</b> </td> <td> <b> System</b> </td> <td> <b> Code</b> </td> </tr> <tr> <td> *</td> <td> 12</td> <td> <a href="http://terminology.hl7.org/5.1.0/CodeSystem-v3-ucum.html">Unified Code for Units of Measure (UCUM)</a> </td> <td> h</td> </tr> </table> </blockquote> </blockquote> </div> </text> <url value="http://example-lab.com/specdef/123455"/> <identifier> <value value="123455"/> </identifier> <title value="Venous blood specimen"/> <status value="active"/> <experimental value="true"/> <typeCollected> <coding> <system value="http://snomed.info/sct"/> <code value="122555007"/> </coding> <text value="Venous blood specimen (specimen)"/> </typeCollected> <patientPreparation> <text value="no strict fasting"/> </patientPreparation> <typeTested> <isDerived value="true"/> <type> <coding> <system value="http://snomed.info/sct"/> <code value="119364003"/> </coding> <text value="Serum specimen (specimen)"/> </type> <preference value="preferred"/> <container> <material> <text value="glass"/> </material> <type> <coding> <system value="http://snomed.info/sct"/> <code value="702281005"/> <display value="Evacuated blood collection tube with thrombin and clot activator and gel separator"/> </coding> </type> <cap> <coding> <system value="http://terminology.hl7.org/5.1.0/CodeSystem-container-cap.html"/> <code value="yellow"/> <display value="yellow cap"/> </coding> </cap> <minimumVolumeQuantity> <value value="2"/> <unit value="ml"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </minimumVolumeQuantity> </container> <handling> <temperatureQualifier> <coding> <code value="room"/> <display value="room temperature"/> </coding> </temperatureQualifier> <temperatureRange> <low> <value value="15"/> <unit value="°C"/> <system value="http://unitsofmeasure.org"/> <code value="Cel"/> </low> <high> <value value="25"/> <unit value="°C"/> <system value="http://unitsofmeasure.org"/> <code value="Cel"/> </high> </temperatureRange> <maxDuration> <value value="12"/> <system value="http://unitsofmeasure.org"/> <code value="h"/> </maxDuration> </handling> </typeTested> </SpecimenDefinition>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0 generated on Sun, Mar 26, 2023 15:26+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4 |
Compare to R4B |
|
Propose a change