This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version in it's permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Example Specimen/sst (Turtle)
Raw Turtle (+ also see Turtle/RDF Format Specification)
Serum Sample
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
[a fhir:Specimen ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "sst"] ; #
fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Specimen</b><a name=\"sst\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Specimen "sst" </p></div><p><b>accessionIdentifier</b>: id: 20150816-00124</p><p><b>type</b>: Serum sample <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#119364003)</span></p><p><b>subject</b>: <a href=\"patient-example-b.html\">Patient/pat2</a> "Duck DONALD"</p><p><b>request</b>: <a href=\"servicerequest-example-ft4.html\">ServiceRequest/ft4</a></p><h3>Collections</h3><table class=\"grid\"><tr><td>-</td><td><b>Collector</b></td><td><b>Collected[x]</b></td></tr><tr><td>*</td><td><a href=\"practitioner-example-f202-lm.html\">Practitioner/f202</a> "Luigi Maas"</td><td>2015-08-16T06:40:17Z</td></tr></table><h3>Containers</h3><table class=\"grid\"><tr><td>-</td><td><b>Device</b></td></tr><tr><td>*</td><td><a href=\"device-example-specimen-container-example-sst-vacutainer.html\">Device/device-example-specimen-container-example-sst-vacutainer</a></td></tr></table></div>"
] ; #
fhir:accessionIdentifier [
fhir:system [ fhir:v "http://acme.com/labs/accession-ids"^^xsd:anyURI ] ;
fhir:value [ fhir:v "20150816-00124" ]
] ; #
fhir:type [
fhir:coding ( [
a sct:119364003 ;
fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ;
fhir:code [ fhir:v "119364003" ] ;
fhir:display [ fhir:v "Serum sample" ]
] )
] ; #
fhir:subject [
fhir:reference [ fhir:v "Patient/pat2" ]
] ; #
fhir:request ( [
fhir:reference [ fhir:v "ServiceRequest/ft4" ]
] ) ; #
fhir:collection [
fhir:collector [
fhir:reference [ fhir:v "Practitioner/f202" ]
] ;
fhir:collected [ fhir:v "2015-08-16T06:40:17Z"^^xsd:dateTime ]
] ; #
fhir:container ( [
fhir:device [
fhir:reference [ fhir:v "Device/device-example-specimen-container-example-sst-vacutainer" ]
]
] )] . #
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the
examples are correct and useful, but they are not a normative part
of the specification.