This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version in it's permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
This is the narrative for the resource. See also the XML, JSON or Turtle format. This example conforms to the profile Observation.
Generated Narrative: Observation
Resource Observation "656"
identifier: id: patientId-urn:oid:1.2.4~0000000000000000~152584~20170503155426~820
status: final
code: MDC_FLOW_AWAY_EXP_FORCED_PEAK (ISO 11073-10101 Health informatics - Point-of-care#152584)
subject: Patient/PatientId-patientId
effective: 2017-05-03T15:54:26-04:00
performer: Patient/PatientId-patientId
value: 820 cL/s (Details: urn:iso:std:iso:11073:10101 code 265201 = '265201')
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.