This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version in it's permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Raw Turtle (+ also see Turtle/RDF Format Specification)
Blood Pressure Measurement cancelled
@prefix fhir: <http://hl7.org/fhir/> . @prefix loinc: <https://loinc.org/rdf/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- [a fhir:Observation ; fhir:nodeRole fhir:treeRoot ; fhir:id [ fhir:v "blood-pressure-cancel"] ; # fhir:meta [ fhir:profile ( [ fhir:v "http://hl7.org/fhir/StructureDefinition/vitalsigns"^^xsd:anyURI ; fhir:link <http://hl7.org/fhir/StructureDefinition/vitalsigns> ] ) ] ; # fhir:text [ fhir:status [ fhir:v "generated" ] ; fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Observation</b><a name=\"blood-pressure-cancel\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Observation "blood-pressure-cancel" </p><p style=\"margin-bottom: 0px\">Profile: <a href=\"vitalsigns.html\">Vital Signs Profile</a></p></div><p><b>identifier</b>: <span title=\" EH Narrative created by build\n <text>\n <status value="generated"/>\n <div xmlns="http://www.w3.org/1999/xhtml">Sept 17, 2012: Systolic Blood pressure 107/60 mmHg (low)</div>\n </text>\n \">id: urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281</span></p><p><b>status</b>: cancelled</p><p><b>category</b>: Vital Signs <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-observation-category.html\">Observation Category Codes</a>#vital-signs)</span></p><p><b>code</b>: Blood pressure systolic & diastolic <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#85354-9 "Blood pressure panel with all children optional")</span></p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</p><p><b>effective</b>: 2012-09-17</p><p><b>performer</b>: <a href=\"practitioner-example.html\">Practitioner/example</a> "Adam CAREFUL"</p><p><b>interpretation</b>: <span title=\" an interpretation offered to the combination observation\n generally, it would only be appropriate to offer an interpretation\n of an observation that has no value if it has "COMP" (component)\n observations \">Below low normal <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-v3-ObservationInterpretation.html\">ObservationInterpretation</a>#L "low")</span></span></p><p><b>note</b>: In this example, the blood pressure measurements are not available due to cancellation of the order. Data absent reason is present for each component</p><p><b>bodySite</b>: <span title=\" for an observation with components, these cannot disagree with the flags on the components \">Right arm <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#368209003)</span></span></p><blockquote><p><b>component</b></p><p><b>code</b>: <span title=\" \n Observations are often coded in multiple code systems.\n - LOINC provides a very specific code (though not usefully more specific in this particular case)\n - snomed provides a clinically relevant code that is usually less granular than LOINC\n - the source system provides its own code, which may be less or more granular than LOINC\n this instance shows the concept. The other codes only have a LOINC code \">Systolic blood pressure <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#8480-6; <a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#271649006; clinical-codes#bp-s "Systolic Blood pressure")</span></span></p><p><b>dataAbsentReason</b>: <span title=\" no value due to some error\n <valueQuantity>\n <value value="107"/>\n <unit value="mm[Hg]"/>\n </valueQuantity>\n \">Not Asked <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-data-absent-reason.html\">DataAbsentReason</a>#not-asked)</span></span></p></blockquote><blockquote><p><b>component</b></p><p><b>code</b>: Diastolic blood pressure <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://loinc.org/\">LOINC</a>#8462-4)</span></p><p><b>dataAbsentReason</b>: <span title=\" no value due to some error\n <valueQuantity>\n <value value="60"/>\n <unit value="mm[Hg]"/>\n </valueQuantity>\n \">Not Asked <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"http://terminology.hl7.org/5.1.0/CodeSystem-data-absent-reason.html\">DataAbsentReason</a>#not-asked)</span></span></p></blockquote></div>" ] ; # EH Narrative created by build # <text> # <status value="generated"/> # <div xmlns="http://www.w3.org/1999/xhtml">Sept 17, 2012: Systolic Blood pressure 107/60 mmHg (low)</div> # </text> # fhir:identifier ( [ fhir:system [ fhir:v "urn:ietf:rfc:3986"^^xsd:anyURI ] ; fhir:value [ fhir:v "urn:uuid:187e0c12-8dd2-67e2-99b2-bf273c878281" ] ] ) ; # fhir:status [ fhir:v "cancelled"] ; # fhir:category ( [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/observation-category"^^xsd:anyURI ] ; fhir:code [ fhir:v "vital-signs" ] ; fhir:display [ fhir:v "Vital Signs" ] ] ) ] ) ; # fhir:code [ fhir:coding ( [ a loinc:85354-9 ; fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ; fhir:code [ fhir:v "85354-9" ] ; fhir:display [ fhir:v "Blood pressure panel with all children optional" ] ] ) ; # replaced by 85354-9\n <coding>\n <system value=\"http:\/\/loinc.org\"\/>\n <code value=\"85354-9\"\/>\n <display value=\"Blood pressure systolic & diastolic\"\/>\n <\/coding>\n fhir:text [ fhir:v "Blood pressure systolic & diastolic" ] ] ; # fhir:subject [ fhir:reference [ fhir:v "Patient/example" ] ] ; # fhir:effective [ fhir:v "2012-09-17"^^xsd:date] ; # fhir:performer ( [ fhir:reference [ fhir:v "Practitioner/example" ] ] ) ; # fhir:interpretation ( [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"^^xsd:anyURI ] ; fhir:code [ fhir:v "L" ] ; fhir:display [ fhir:v "low" ] ] ) ; fhir:text [ fhir:v "Below low normal" ] ] ) ; # an interpretation offered to the combination observation # generally, it would only be appropriate to offer an interpretation # of an observation that has no value if it has "COMP" (component) # observations fhir:note ( [ fhir:text [ fhir:v "In this example, the blood pressure measurements are not available due to cancellation of the order. Data absent reason is present for each component" ] ] ) ; # fhir:bodySite [ fhir:coding ( [ a sct:368209003 ; fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ; fhir:code [ fhir:v "368209003" ] ; fhir:display [ fhir:v "Right arm" ] ] ) ] ; # for an observation with components, these cannot disagree with the flags on the components fhir:component ( [ fhir:code [ fhir:coding ( [ a loinc:8480-6 ; fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ; fhir:code [ fhir:v "8480-6" ] ; fhir:display [ fhir:v "Systolic blood pressure" ] ] [ a sct:271649006 ; fhir:system [ fhir:v "http://snomed.info/sct"^^xsd:anyURI ] ; fhir:code [ fhir:v "271649006" ] ; fhir:display [ fhir:v "Systolic blood pressure" ] ] [ fhir:system [ fhir:v "http://acme.org/devices/clinical-codes"^^xsd:anyURI ] ; fhir:code [ fhir:v "bp-s" ] ; fhir:display [ fhir:v "Systolic Blood pressure" ] ] ) # LOINC - always recommended to have a LOINC code ] ; # \n Observations are often coded in multiple code systems.\n - LOINC provides a very specific code (though not usefully more specific in this particular case)\n - snomed provides a clinically relevant code that is usually less granular than LOINC\n - the source system provides its own code, which may be less or more granular than LOINC\n this instance shows the concept. The other codes only have a LOINC code , that shows the concept. The next two names only have a LOINC code fhir:dataAbsentReason [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/data-absent-reason"^^xsd:anyURI ] ; fhir:code [ fhir:v "not-asked" ] ; fhir:display [ fhir:v "Not Asked" ] ] ) ] # no value due to some error\n <valueQuantity>\n <value value=\"107\"\/>\n <unit value=\"mm[Hg]\"\/>\n <\/valueQuantity>\n ] [ fhir:code [ fhir:coding ( [ a loinc:8462-4 ; fhir:system [ fhir:v "http://loinc.org"^^xsd:anyURI ] ; fhir:code [ fhir:v "8462-4" ] ; fhir:display [ fhir:v "Diastolic blood pressure" ] ] ) ] ; fhir:dataAbsentReason [ fhir:coding ( [ fhir:system [ fhir:v "http://terminology.hl7.org/CodeSystem/data-absent-reason"^^xsd:anyURI ] ; fhir:code [ fhir:v "not-asked" ] ; fhir:display [ fhir:v "Not Asked" ] ] ) ] # no value due to some error\n <valueQuantity>\n <value value=\"60\"\/>\n <unit value=\"mm[Hg]\"\/>\n <\/valueQuantity>\n ] )] . # # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 hl7.fhir.core#5.0.0 generated on Sun, Mar 26, 2023 15:25+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4 |
Compare to R4B |
|
Propose a change