This page is part of the FHIR Specification (v5.0.0: R5 - STU). This is the current published version in it's permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions . Page versions: R5 R3
Example Device/example-udi2 (Turtle)
Raw Turtle (+ also see Turtle/RDF Format Specification)
example-udi2
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
# 014032 = this is the expiration date expressed in YYYDDD (three digit year, three digit day number)
# <association>
# <status>
# <coding>
# <system value="http://terminology.hl7.org/CodeSystem/device-associationstatus" />
# <code value="attached"/>
# </coding>
# </status>
# <humanSubject>
# <reference value="Patient/example"/>
# </humanSubject>
# </association>
[a fhir:Device ;
fhir:nodeRole fhir:treeRoot ;
fhir:id [ fhir:v "example-udi2"] ; #
fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"example-udi2\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "example-udi2" </p></div><p><b>identifier</b>: A99971312345600</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td></tr><tr><td>*</td><td>A9999XYZ100T0474</td><td><a href=\"http://hl7.org/fhir/NamingSystem/iccbba-other\">http://hl7.org/fhir/NamingSystem/iccbba-other</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td></tr></table><p><b>status</b>: inactive</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>manufactureDate</b>: 2013-02-01</p><p><b>expirationDate</b>: <span title=\" 013032 = this is the manufacturing date expressed in YYYDDD (three digit year, three digit day number) \">2014-02-01</span></p></div>"
] ; #
fhir:identifier ( [
fhir:type [
fhir:coding ( [
fhir:system [ fhir:v "http://hl7.org/fhir/NamingSystem/iccbba-din"^^xsd:anyURI ]
] )
] ;
fhir:value [ fhir:v "A99971312345600" ]
] ) ; #
fhir:udiCarrier ( [
fhir:deviceIdentifier [ fhir:v "A9999XYZ100T0474" ] ;
fhir:issuer [ fhir:v "http://hl7.org/fhir/NamingSystem/iccbba-other"^^xsd:anyURI ] ;
fhir:jurisdiction [ fhir:v "http://hl7.org/fhir/NamingSystem/fda-udi"^^xsd:anyURI ]
] ) ; #
fhir:status [ fhir:v "inactive"] ; #
fhir:manufacturer [ fhir:v "Acme Devices, Inc"] ; #
fhir:manufactureDate [ fhir:v "2013-02-01"^^xsd:date] ; #
fhir:expirationDate [ fhir:v "2014-02-01"^^xsd:date]] . # 013032 = this is the manufacturing date expressed in YYYDDD (three digit year, three digit day number)
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the
examples are correct and useful, but they are not a normative part