ImagingStudy | |
Definition | Representation of the content produced in a DICOM imaging study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities. |
Control | 1..1 |
Summary | true |
ImagingStudy.started | |
Definition | Date and Time the study started. |
Control | 0..1 |
Type | dateTime |
Alternate Names | StudyDate; StudyTime |
Summary | true |
ImagingStudy.patient | |
Definition | The patient imaged in the study. |
Control | 1..1 |
Type | Reference(Patient) |
Summary | true |
ImagingStudy.uid | |
Definition | Formal identifier for the study. |
Control | 1..1 |
Type | oid |
Alternate Names | StudyInstanceUID |
Summary | true |
ImagingStudy.accession | |
Definition | Accession Number is an identifier related to some aspect of imaging workflow and data management. Usage may vary across different institutions. See for instance IHE Radiology Technical Framework Volume 1 Appendix A . |
Control | 0..1 |
Type | Identifier |
Alternate Names | AccessionNumber |
Summary | true |
ImagingStudy.identifier | |
Definition | Other identifiers for the study. |
Note | This is a business identifer, not a resource identifier (see discussion) |
Control | 0..* |
Type | Identifier |
Alternate Names | StudyID |
Summary | true |
ImagingStudy.order | |
Definition | A list of the diagnostic orders that resulted in this imaging study being performed. |
Control | 0..* |
Type | Reference(DiagnosticOrder) |
Requirements | To support grouped procedures (one imaging study supporting multiple ordered procedures, e.g. chest/abdomen/pelvis CT). |
Summary | true |
ImagingStudy.modalityList | |
Definition | A list of all the Series.ImageModality values that are actual acquisition modalities, i.e. those in the DICOM Context Group 29 (value set OID 1.2.840.10008.6.1.19). |
Control | 0..* |
Binding | Acquisition Modality Codes: Type of acquired data in the instance (Extensible) |
Type | Coding |
Alternate Names | ModalitiesInStudy |
Summary | true |
ImagingStudy.referrer | |
Definition | The requesting/referring physician. |
Control | 0..1 |
Type | Reference(Practitioner) |
Alternate Names | ReferringPhysiciansName |
Summary | true |
ImagingStudy.availability | |
Definition | Availability of study (online, offline or nearline). |
Control | 0..1 |
Binding | InstanceAvailability: Availability of the resource (Required) |
Type | code |
Alternate Names | InstanceAvailability |
Summary | true |
ImagingStudy.url | |
Definition | WADO-RS resource where Study is available. |
Control | 0..1 |
Type | uri |
Alternate Names | RetrieveURI |
Summary | true |
ImagingStudy.numberOfSeries | |
Definition | Number of Series in Study. |
Control | 1..1 |
Type | unsignedInt |
Alternate Names | NumberOfStudyRelatedSeries |
Summary | true |
ImagingStudy.numberOfInstances | |
Definition | Number of SOP Instances in Study. |
Control | 1..1 |
Type | unsignedInt |
Alternate Names | NumberOfStudyRelatedInstances |
Summary | true |
ImagingStudy.procedure | |
Definition | Type of procedure performed. |
Control | 0..* |
Type | Reference(Procedure) |
Alternate Names | ProcedureCodeSequence |
Summary | true |
Comments | For the Procedure.code, LOINC radiology orderables would be a good value set to use. |
ImagingStudy.interpreter | |
Definition | Who read the study and interpreted the images or other content. |
Control | 0..1 |
Type | Reference(Practitioner) |
Alternate Names | Name of Physician(s) Reading Study |
Summary | true |
ImagingStudy.description | |
Definition | Institution-generated description or classification of the Study performed. |
Control | 0..1 |
Type | string |
Alternate Names | StudyDescription |
Summary | true |
ImagingStudy.series | |
Definition | Each study has one or more series of images or other content. |
Control | 0..* |
Summary | true |
ImagingStudy.series.number | |
Definition | The Numeric identifier of this series in the study. |
Control | 0..1 |
Type | unsignedInt |
Alternate Names | SeriesNumber |
Summary | true |
ImagingStudy.series.modality | |
Definition | The modality of this series sequence. |
Control | 1..1 |
Binding | Acquisition Modality Codes: Type of acquired data in the instance (Extensible) |
Type | Coding |
Alternate Names | Modality |
Summary | true |
ImagingStudy.series.uid | |
Definition | Formal identifier for this series. |
Control | 1..1 |
Type | oid |
Alternate Names | SeriesInstanceUID |
Summary | true |
ImagingStudy.series.description | |
Definition | A description of the series. |
Control | 0..1 |
Type | string |
Alternate Names | SeriesDescription |
Summary | true |
ImagingStudy.series.numberOfInstances | |
Definition | Number of SOP Instances in Series. |
Control | 1..1 |
Type | unsignedInt |
Alternate Names | NumberOfSeriesRelatedInstances |
Summary | true |
ImagingStudy.series.availability | |
Definition | Availability of series (online, offline or nearline). |
Control | 0..1 |
Binding | InstanceAvailability: Availability of the resource (Required) |
Type | code |
Alternate Names | InstanceAvailability |
Summary | true |
ImagingStudy.series.url | |
Definition | URI/URL specifying the location of the referenced series using WADO-RS. |
Control | 0..1 |
Type | uri |
Alternate Names | RetrieveURI |
Summary | true |
ImagingStudy.series.bodySite | |
Definition | Body part examined. See DICOM Part 16 Annex L for the mapping from DICOM to Snomed CT. |
Control | 0..1 |
Binding | SNOMED CT Body Structures: Codes describing anatomical locations. May include laterality. (Example) |
Type | Coding |
Alternate Names | BodyPartExamined |
Summary | true |
ImagingStudy.series.laterality | |
Definition | Laterality if body site is paired anatomic structure and laterality is not pre-coordinated in body site code. |
Control | 0..1 |
Binding | Laterality: Codes describing body site laterality (left, right, etc.). (Example) |
Type | Coding |
Summary | true |
ImagingStudy.series.started | |
Definition | The date and time the series was started. |
Control | 0..1 |
Type | dateTime |
Summary | true |
ImagingStudy.series.instance | |
Definition | A single SOP Instance within the series, e.g. an image, or presentation state. |
Control | 0..* |
Summary | true |
ImagingStudy.series.instance.number | |
Definition | The number of instance in the series. |
Control | 0..1 |
Type | unsignedInt |
Alternate Names | InstanceNumber |
Summary | true |
ImagingStudy.series.instance.uid | |
Definition | Formal identifier for this image or other content. |
Control | 1..1 |
Type | oid |
Alternate Names | SOPInstanceUID |
Summary | true |
ImagingStudy.series.instance.sopClass | |
Definition | DICOM instance type. |
Control | 1..1 |
Type | oid |
Alternate Names | SOPClassUID |
Summary | true |
ImagingStudy.series.instance.type | |
Definition | A human-friendly SOP Class name. |
Control | 0..1 |
Type | string |
Summary | true |
Comments | E.g. 'CT image', 'MR multi-frame', 'blending presentation'. |
ImagingStudy.series.instance.title | |
Definition | The description of the instance. |
Control | 0..1 |
Type | string |
Summary | true |
Comments | Particularly for post-acquisition analytic objects, such as SR, presentation states, value mapping, etc. |
ImagingStudy.series.instance.content | |
Definition | Content of the instance or a rendering thereof (e.g. a JPEG of an image, or an XML of a structured report). May be represented for example by inline encoding; by a URL reference to a WADO-RS service that makes the instance available; or to a FHIR Resource (e.g. Media, Document, etc.). Multiple content attachments may be used for alternate representations of the instance. |
Control | 0..* |
Type | Attachment |
Summary | true |
Comments | Use of Attachment.data is discouraged. |