R6 Ballot (2nd Draft)

Publish-box (todo)

Example Device/example-udi1 (XML)

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: No defined compartments

Raw XML (canonical form + also see XML Format Specification)

example-udi1 (id = "example-udi1")

<?xml version="1.0" encoding="UTF-8"?>

<!--  The use case illustrates the use of an  UDI for an implant  is built with GS-1
 format UDI data  --><Device xmlns="http://hl7.org/fhir">
  <id value="example-udi1"/> 
  <identifier> 
    <type> 
      <coding> 
        <system value="http://acme.com/devices/pacemakers/octane/serial"/> 
      </coding> 
    </type> 
    <value value="1234-5678-90AB-CDEF"/> 
  </identifier> 
  <identifier> 
    <type> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/v2-0203"/> 
        <code value="SNO"/> 
      </coding> 
    </type> 
    <value value="10987654d321"/> 
  </identifier> 
  <udiCarrier> 
    <deviceIdentifier value="00844588003288"/> 
    <issuer value="http://hl7.org/fhir/NamingSystem/gs1"/> 
    <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> 
    <carrierAIDC value="XWQyMDExMDg1NzY3NDAwMjAxNzE3MTQxMTIwMTBOWUZVTDAx4oaUMjExOTI4MzfihpQ3MTNBMUIyQzNENEU1RjZH"/> 
    <carrierHRF value="{01}00844588003288{17}141120{10}7654321D{21}10987654d321"/> 
    <entryType value="barcode"/> 
  </udiCarrier> 
  <status value="active"/> 
  <manufacturer value="Acme Devices, Inc"/> 
  <expirationDate value="2014-11-20"/> 
  <lotNumber value="7654321D"/> 
  <name> 
    <value value="PM/Octane 2014"/> 
    <type/>  
  </name> 
  <!--   note: optional text value added here for a prettier generated narrative   -->
  <type> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="468063009"/> 
      <display value="Coated femoral stem prosthesis, modular"/> 
    </coding> 
    <text value="Coated femoral stem prosthesis, modular"/> 
  </type> 
  <!--   <association>
    <status> 
       <coding>
       <system value="http://terminology.hl7.org/CodeSystem/device-association-status"
   />
           <code value="attached"/>
     </coding>
    </status>
      <humanSubject>
    <reference value="Patient/example"/>
    </humanSubject>
  </association>   -->
  <!--   note: optional text value added here for a prettier generated narrative   -->
  <safety> 
    <coding> 
      <system value="urn:oid:2.16.840.1.113883.3.26.1.1"/> 
      <code value="mr-unsafe"/> 
      <display value="MR Unsafe"/> 
    </coding> 
    <text value="MR Unsafe"/> 
  </safety> 
</Device> 