NoninBlePulseOx
{
"resourceType" : "Device",
"id" : "NoninBlePulseOx",
"identifier" : [{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "SYSID",
"display" : "System Identifier"
}]
},
"system" : "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value" : "74-E8-FF-FE-FF-05-1C-00"
},
{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
"code" : "BTMAC",
"display" : "Bluetooth Address"
}]
},
"system" : "http://hl7.org/fhir/sid/eui-48",
"value" : "00-1C-05-FF-E8-74"
}],
"udiCarrier" : [{
"deviceIdentifier" : "120359741556",
"issuer" : "http://hl7.org/fhir/NamingSystem/gs1-di",
"jurisdiction" : "http://hl7.org/fhir/NamingSystem/fda-udi",
"carrierHRF" : "(01)120359741556(21)501900083",
"entryType" : "unknown"
}],
"manufacturer" : "Nonin_Medical_Inc.",
"serialNumber" : "501900083",
"name" : [{
"value" : "Nonin3230_501900083"
}],
"modelNumber" : "Model 3230",
"type" : [{
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "65573",
"display" : "MDC_MOC_VMS_MDS_SIMP"
}],
"text" : "MDC_MOC_VMS_MDS_SIMP: Personal Health Device"
}],
"deviceVersion" : [{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531976"
}],
"text" : "MDC_ID_PROD_SPEC_FW: Firmware revision"
},
"value" : "r2.1"
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531975"
}],
"text" : "MDC_ID_PROD_SPEC_SW: Software revision"
},
"value" : "r1.5 9.7"
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "531974"
}],
"text" : "MDC_ID_PROD_SPEC_HW: Hardware revision"
},
"value" : "r1.0"
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532352"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"
},
"value" : "6.0"
}],
"conformsTo" : [{
"specification" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "528388"
}],
"text" : "MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"
},
"version" : "1"
}],
"property" : [{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532353"
}],
"text" : "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ContinuaPAN",
"code" : "4"
}]
}
},
{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code" : "532354.0"
}],
"text" : "regulation-status"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "N"
}],
"text" : "Device is Regulated"
}
},
{
"type" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "68220"
}],
"text" : "MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "532224"
}],
"text" : "MDC_TIME_SYNC_NONE: No time synchronization"
}
},
{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code" : "68219.0"
}],
"text" : "mds-time-capab-real-time-clock"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "Y"
}],
"text" : "real time clock supported"
}
},
{
"type" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/ASN1ToHL7",
"code" : "68219.1"
}],
"text" : "mds-time-capab-set-clock"
},
"valueCodeableConcept" : {
"coding" : [{
"system" : "http://terminology.hl7.org/CodeSystem/v2-0136",
"code" : "Y"
}],
"text" : "setting the time supported"
}
}]
}