Publish-box (todo)
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw XML (canonical form + also see XML Format Specification)
Bodimetrics (id = "Bodimetrics")
<?xml version="1.0" encoding="UTF-8"?> <Device xmlns="http://hl7.org/fhir"> <id value="Bodimetrics"/> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="SYSID"/> <display value="System Identifier"/> </coding> </type> <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> <value value="00-00-00-00-00-00-00-00"/> </identifier> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="BTMAC"/> <display value="Bluetooth Address"/> </coding> </type> <system value="http://hl7.org/fhir/sid/eui-48"/> <value value="00-17-E9-54-C8-52"/> </identifier> <udiCarrier> <deviceIdentifier value="102698895442"/> <issuer value="http://hl7.org/fhir/NamingSystem/gs1-di"/> <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> <carrierHRF value="(01)102698895442(21)1607124656"/> <entryType value="unknown"/> </udiCarrier> <manufacturer value="BodiMetrics"/> <serialNumber value="1607124656"/> <name> <value value="BM-88 4656"/> <type/> </name> <modelNumber value="6611"/> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="65573"/> <display value="MDC_MOC_VMS_MDS_SIMP"/> </coding> <text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/> </type> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531975"/> </coding> <text value="MDC_ID_PROD_SPEC_SW: Software revision"/> </type> <value value="020008"/> </deviceVersion> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531974"/> </coding> <text value="MDC_ID_PROD_SPEC_HW: Hardware revision"/> </type> <value value="CC"/> </deviceVersion> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528391"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_BP: Blood Pressure meter"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528457"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_GENERIC: Generic 20601 device"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528390"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_MIN_ECG: Electro cardiogram"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528388"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"/> </specification> <version value="1"/> </conformsTo> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528392"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_TEMP: Thermometer"/> </specification> <version value="1"/> </conformsTo> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="68220"/> </coding> <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> </type> <valueCodeableConcept> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532224"/> </coding> <text value="MDC_TIME_SYNC_NONE: No time synchronization"/> </valueCodeableConcept> </property> </Device>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R6 hl7.fhir.core#6.0.0-ballot2 generated on Mon, Aug 12, 2024 16:58+0800.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R5 |
|
Propose a change