Publish-box (todo)
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: No defined compartments |
Raw XML (canonical form + also see XML Format Specification)
ANDThermometer (id = "ANDThermometer")
<?xml version="1.0" encoding="UTF-8"?> <Device xmlns="http://hl7.org/fhir"> <id value="ANDThermometer"/> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="SYSID"/> <display value="System Identifier"/> </coding> </type> <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/> <value value="54-4A-16-FF-FE-32-12-26"/> </identifier> <identifier> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/> <code value="BTMAC"/> <display value="Bluetooth Address"/> </coding> </type> <system value="http://hl7.org/fhir/sid/eui-48"/> <value value="54-4A-16-32-12-26"/> </identifier> <udiCarrier> <deviceIdentifier value="92677176693286"/> <issuer value="http://hl7.org/fhir/NamingSystem/gs1-di"/> <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> <carrierHRF value="(01)92677176693286(21)5160800011"/> <entryType value="unknown"/> </udiCarrier> <manufacturer value="A&D Medical"/> <serialNumber value="5160800011"/> <name> <value value="A&D_UT201BLEA_321226"/> <type/> </name> <modelNumber value="UT-201BLE-A"/> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="65573"/> <display value="MDC_MOC_VMS_MDS_SIMP"/> </coding> <text value="MDC_MOC_VMS_MDS_SIMP: Personal Health Device"/> </type> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531976"/> </coding> <text value="MDC_ID_PROD_SPEC_FW: Firmware revision"/> </type> <value value="HTP009_137"/> </deviceVersion> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531975"/> </coding> <text value="MDC_ID_PROD_SPEC_SW: Software revision"/> </type> <value value="0.00"/> </deviceVersion> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="531974"/> </coding> <text value="MDC_ID_PROD_SPEC_HW: Hardware revision"/> </type> <value value="0.00"/> </deviceVersion> <deviceVersion> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532352"/> </coding> <text value="MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"/> </type> <value value="4.1"/> </deviceVersion> <conformsTo> <specification> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="528392"/> </coding> <text value="MDC_DEV_SPEC_PROFILE_TEMP: Thermometer"/> </specification> <version value="1"/> </conformsTo> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532353"/> </coding> <text value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"/> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/ContinuaPAN"/> <code value="32776"/> </coding> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="532354.0"/> <display value="regulation-status"/> </coding> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="N"/> </coding> <text value="Device is Regulated"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="68220"/> </coding> <text value="MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"/> </type> <valueCodeableConcept> <coding> <system value="urn:iso:std:iso:11073:10101"/> <code value="532224"/> </coding> <text value="MDC_TIME_SYNC_NONE: No time synchronization"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="68219.0"/> <display value="mds-time-capab-real-time-clock"/> </coding> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="Y"/> </coding> <text value="real time clock supported"/> </valueCodeableConcept> </property> <property> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/> <code value="68219.1"/> <display value="mds-time-capab-set-clock"/> </coding> </type> <valueCodeableConcept> <coding> <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/> <code value="Y"/> </coding> <text value="setting the time supported"/> </valueCodeableConcept> </property> </Device>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R6 hl7.fhir.core#6.0.0-ballot2 generated on Mon, Aug 12, 2024 16:58+0800.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R5 |
|
Propose a change