Snapshot 3: Connectathon 32 Base

This is Snapshot #3 for FHIR R5, released to support Connectathon 32. For a full list of available versions, see the Directory of published versions.

Example Procedure/example-implant (XML)

Patient Care Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Example of a device manipulation (id = "example-implant")

<?xml version="1.0" encoding="UTF-8"?>

<Procedure xmlns="http://hl7.org/fhir">
  <id value="example-implant"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Procedure</b> <a name="example-implant"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Procedure &quot;example-implant&quot; </p> </div> <p> <b> status</b> : completed</p> <p> <b> code</b> : Implant Pacemaker <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #25267002 &quot;Insertion of intracardiac pacemaker (procedure)&quot;)</span> </p> <p> <b> subject</b> : <a href="patient-example.html">Patient/example</a>  &quot;Peter CHALMERS&quot;</p> <p> <b> occurrence</b> : 2015-04-05</p> <h3> Performers</h3> <table class="grid"><tr> <td> -</td> <td> <b> Actor</b> </td> </tr> <tr> <td> *</td> <td> <a href="practitioner-example.html">Practitioner/example: Dr Cecil Surgeon</a>  &quot;Adam CAREFUL&quot;</td> </tr> </table> <h3> Reasons</h3> <table class="grid"><tr> <td> -</td> <td> <b> Concept</b> </td> </tr> <tr> <td> *</td> <td> Bradycardia <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span> </td> </tr> </table> <p> <b> followUp</b> : ROS 5 days  - 2013-04-10 <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> ()</span> </p> <p> <b> note</b> : Routine Appendectomy. Appendix was inflamed and in retro-caecal position</p> <h3> FocalDevices</h3> <table class="grid"><tr> <td> -</td> <td> <b> Action</b> </td> <td> <b> Manipulated</b> </td> </tr> <tr> <td> *</td> <td> Implanted <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-device-action.html">Procedure Device Action Codes</a> #implanted)</span> </td> <td> <a name="example-pacemaker"> </a> <blockquote> <p/>  <p> <a name="example-pacemaker"> </a> </p> <p> <b> manufacturer</b> : Acme Devices, Inc</p> <p> <b> lotNumber</b> : 1234-5678</p> <p> <b> type</b> : Cardiac pacemaker implant <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="https://browser.ihtsdotools.org/">SNOMED CT</a> #14106009)</span> </p> <h3> Associations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Status</b> </td> <td> <b> HumanSubject</b> </td> </tr> <tr> <td> *</td> <td> Implanted <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="codesystem-device-association-status.html">FHIRDeviceaAsociationStatus</a> #implanted)</span> </td> <td> <a href="patient-example.html">Patient/example</a>  &quot;Peter CHALMERS&quot;</td> </tr> </table> </blockquote> </td> </tr> </table> </div> </text> <contained> 
  <Device> 
    <id value="example-pacemaker"/> 
    <manufacturer value="Acme Devices, Inc"/>  
    <lotNumber value="1234-5678"/>  
    <type>  
      <coding>  
        <system value="http://snomed.info/sct"/>  
        <code value="14106009"/>  
        <display value="Cardiac pacemaker implant"/>  
      </coding>  
    </type>  
    <association>  
      <status>  
        <coding> 
          <system value="http://hl7.org/fhir/device-association-status"/> 
          <code value="implanted"/> 
        </coding> 
      </status> 
      <humanSubject>  
        <reference value="Patient/example"/>  
      </humanSubject>  
    </association>  
  </Device> 
  </contained> 
  <status value="completed"/> 
  <code> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="25267002"/> 
      <display value="Insertion of intracardiac pacemaker (procedure)"/> 
    </coding> 
    <text value="Implant Pacemaker"/> 
  </code> 
  <subject>  
    <reference value="Patient/example"/>  
  </subject>  
  <occurrenceDateTime value="2015-04-05"/> 
  <performer> 
    <actor> 
      <reference value="Practitioner/example"/> 
      <display value="Dr Cecil Surgeon"/> 
    </actor> 
  </performer> 
  <reason> 
       <concept> 
       <text value="Bradycardia"/> 
       </concept> 
  </reason> 
  <followUp> 
      <text value="ROS 5 days  - 2013-04-10"/> 
  </followUp> 
  <note>  <text value="Routine Appendectomy. Appendix was inflamed and in retro-caecal position"/> 
  </note> 
  <focalDevice> 
    <action> 
      <coding> 
        <system value="http://hl7.org/fhir/device-action"/> 
        <code value="implanted"/> 
      </coding> 
    </action> 
    <manipulated> 
      <reference value="#example-pacemaker"/> 
    </manipulated> 
  </focalDevice> 
</Procedure> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.