This is Snapshot #3 for FHIR R5, released to support Connectathon 32. For a full list of available versions, see the Directory of published versions.
Patient Care Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Encounter, Patient, Practitioner, RelatedPerson |
Raw Turtle (+ also see Turtle/RDF Format Specification)
Example of a device manipulation
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- [a fhir:Procedure; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "example-implant"]; # fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Procedure</b><a name=\"example-implant\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Procedure "example-implant" </p></div><p><b>status</b>: completed</p><p><b>code</b>: Implant Pacemaker <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#25267002 "Insertion of intracardiac pacemaker (procedure)")</span></p><p><b>subject</b>: <a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</p><p><b>occurrence</b>: 2015-04-05</p><h3>Performers</h3><table class=\"grid\"><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a href=\"practitioner-example.html\">Practitioner/example: Dr Cecil Surgeon</a> "Adam CAREFUL"</td></tr></table><h3>Reasons</h3><table class=\"grid\"><tr><td>-</td><td><b>Concept</b></td></tr><tr><td>*</td><td>Bradycardia <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></td></tr></table><p><b>followUp</b>: ROS 5 days - 2013-04-10 <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> ()</span></p><p><b>note</b>: Routine Appendectomy. Appendix was inflamed and in retro-caecal position</p><h3>FocalDevices</h3><table class=\"grid\"><tr><td>-</td><td><b>Action</b></td><td><b>Manipulated</b></td></tr><tr><td>*</td><td>Implanted <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"codesystem-device-action.html\">Procedure Device Action Codes</a>#implanted)</span></td><td><a name=\"example-pacemaker\"> </a><blockquote><p/><p><a name=\"example-pacemaker\"> </a></p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>lotNumber</b>: 1234-5678</p><p><b>type</b>: Cardiac pacemaker implant <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"https://browser.ihtsdotools.org/\">SNOMED CT</a>#14106009)</span></p><h3>Associations</h3><table class=\"grid\"><tr><td>-</td><td><b>Status</b></td><td><b>HumanSubject</b></td></tr><tr><td>*</td><td>Implanted <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (<a href=\"codesystem-device-association-status.html\">FHIRDeviceaAsociationStatus</a>#implanted)</span></td><td><a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</td></tr></table></blockquote></td></tr></table></div>" ]; # fhir:DomainResource.contained [ a fhir:Device; fhir:index 0; fhir:Resource.id [ fhir:value "example-pacemaker" ]; fhir:Device.manufacturer [ fhir:value "Acme Devices, Inc" ]; fhir:Device.lotNumber [ fhir:value "1234-5678" ]; fhir:Device.type [ fhir:index 0; fhir:CodeableConcept.coding [ fhir:index 0; a sct:14106009; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "14106009" ]; fhir:Coding.display [ fhir:value "Cardiac pacemaker implant" ] ] ]; fhir:Device.association [ fhir:index 0; fhir:Device.association.status [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/device-association-status" ]; fhir:Coding.code [ fhir:value "implanted" ] ] ]; fhir:Device.association.humanSubject [ fhir:Reference.reference [ fhir:value "Patient/example" ] ] ] ]; # fhir:Procedure.status [ fhir:value "completed"]; # fhir:Procedure.code [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:25267002; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "25267002" ]; fhir:Coding.display [ fhir:value "Insertion of intracardiac pacemaker (procedure)" ] ]; fhir:CodeableConcept.text [ fhir:value "Implant Pacemaker" ] ]; # fhir:Procedure.subject [ fhir:Reference.reference [ fhir:value "Patient/example" ] ]; # fhir:Procedure.occurrenceDateTime [ fhir:value "2015-04-05"^^xsd:date]; # fhir:Procedure.performer [ fhir:index 0; fhir:Procedure.performer.actor [ fhir:Reference.reference [ fhir:value "Practitioner/example" ]; fhir:Reference.display [ fhir:value "Dr Cecil Surgeon" ] ] ]; # fhir:Procedure.reason [ fhir:index 0; fhir:CodeableReference.concept [ fhir:CodeableConcept.text [ fhir:value "Bradycardia" ] ] ]; # fhir:Procedure.followUp [ fhir:index 0; fhir:CodeableConcept.text [ fhir:value "ROS 5 days - 2013-04-10" ] ]; # fhir:Procedure.note [ fhir:index 0; fhir:Annotation.text [ fhir:value "Routine Appendectomy. Appendix was inflamed and in retro-caecal position" ] ]; # fhir:Procedure.focalDevice [ fhir:index 0; fhir:Procedure.focalDevice.action [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/device-action" ]; fhir:Coding.code [ fhir:value "implanted" ] ] ]; fhir:Procedure.focalDevice.manipulated [ fhir:Reference.reference [ fhir:value "#example-pacemaker" ] ] ]] . # # - ontology header ------------------------------------------------------------ [a owl:Ontology; owl:imports fhir:fhir.ttl] . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.
FHIR ®© HL7.org 2011+. FHIR R5 Ballot hl7.fhir.core#5.0.0-snapshot3 generated on Wed, Dec 14, 2022 07:17+1100.
Links: Search |
Version History |
Contents |
Glossary |
QA |
Compare to R4B |
Compare to R5 Draft |
|
Propose a change