example-udi2 (id = "example-udi2")

<?xml version="1.0" encoding="UTF-8"?>

<Device xmlns="http://hl7.org/fhir">
  <id value="example-udi2"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative: Device</b> <a name="example-udi2"> </a> </p> <div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border:
       1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Device &quot;example-udi2&quot; </p> </div> <p> <b> identifier</b> : A99971312345600</p> <h3> UdiCarriers</h3> <table class="grid"><tr> <td> -</td> <td> <b> DeviceIdentifier</b> </td> <td> <b> Issuer</b> </td> <td> <b> Jurisdiction</b> </td> </tr> <tr> <td> *</td> <td> A9999XYZ100T0474</td> <td> <a href="http://hl7.org/fhir/NamingSystem/iccbba-other">http://hl7.org/fhir/NamingSystem/iccbba-other</a> </td> <td> <a href="http://hl7.org/fhir/NamingSystem/fda-udi">http://hl7.org/fhir/NamingSystem/fda-udi</a> </td> </tr> </table> <p> <b> status</b> : inactive</p> <p> <b> manufacturer</b> : Acme Devices, Inc</p> <p> <b> manufactureDate</b> : 2013-02-01</p> <p> <b> expirationDate</b> : <span title="   013032 = this is the manufacturing date expressed in YYYDDD (three digit year,
         three digit day number) ">2014-02-01</span> </p> <h3> Associations</h3> <table class="grid"><tr> <td> -</td> <td> <b> Status</b> </td> <td> <b> HumanSubject</b> </td> </tr> <tr> <td> *</td> <td> attached <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (device-associationstatus#attached)</span> </td> <td> <a href="patient-example.html">Patient/example</a>  &quot;Peter CHALMERS&quot;</td> </tr> </table> </div> </text> <identifier> 
     <type> 
       <coding> 
            <system value="http://hl7.org/fhir/NamingSystem/iccbba-din"/> 
      </coding> 
     </type> 
     <value value="A99971312345600"/> 
  </identifier> 
  <udiCarrier> 
    <deviceIdentifier value="A9999XYZ100T0474"/> 
    <issuer value="http://hl7.org/fhir/NamingSystem/iccbba-other"/> 
    <jurisdiction value="http://hl7.org/fhir/NamingSystem/fda-udi"/> 
  </udiCarrier> 
  <status value="inactive"/> 
  <manufacturer value="Acme Devices, Inc"/> 
  <manufactureDate value="2013-02-01"/> 
      <!--     013032 = this is the manufacturing date expressed in YYYDDD (three digit year,
   three digit day number)   -->
  <expirationDate value="2014-02-01"/> 
      <!--   014032 = this is the expiration date expressed in YYYDDD (three digit year, three
   digit day number)   -->
  <association> 
    <status>  
       <coding> 
       <system value="http://terminology.hl7.org/CodeSystem/device-associationstatus"/> 
           <code value="attached"/> 
     </coding> 
    </status> 
      <humanSubject> 
    <reference value="Patient/example"/> 
    </humanSubject> 
  </association> 
</Device> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.