Example Device/example-udi2 (Turtle)
Raw Turtle (+ also see Turtle/RDF Format Specification)
example-udi2
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
[a fhir:Device;
fhir:nodeRole fhir:treeRoot;
fhir:Resource.id [ fhir:value "example-udi2"]; #
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "generated" ];
fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative: Device</b><a name=\"example-udi2\"> </a></p><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">Resource Device "example-udi2" </p></div><p><b>identifier</b>: A99971312345600</p><h3>UdiCarriers</h3><table class=\"grid\"><tr><td>-</td><td><b>DeviceIdentifier</b></td><td><b>Issuer</b></td><td><b>Jurisdiction</b></td></tr><tr><td>*</td><td>A9999XYZ100T0474</td><td><a href=\"http://hl7.org/fhir/NamingSystem/iccbba-other\">http://hl7.org/fhir/NamingSystem/iccbba-other</a></td><td><a href=\"http://hl7.org/fhir/NamingSystem/fda-udi\">http://hl7.org/fhir/NamingSystem/fda-udi</a></td></tr></table><p><b>status</b>: inactive</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>manufactureDate</b>: 2013-02-01</p><p><b>expirationDate</b>: <span title=\" 013032 = this is the manufacturing date expressed in YYYDDD (three digit year, three digit day number) \">2014-02-01</span></p><h3>Associations</h3><table class=\"grid\"><tr><td>-</td><td><b>Status</b></td><td><b>HumanSubject</b></td></tr><tr><td>*</td><td>attached <span style=\"background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki\"> (device-associationstatus#attached)</span></td><td><a href=\"patient-example.html\">Patient/example</a> "Peter CHALMERS"</td></tr></table></div>"
]; #
fhir:Device.identifier [
fhir:index 0;
fhir:Identifier.type [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/NamingSystem/iccbba-din" ]
]
];
fhir:Identifier.value [ fhir:value "A99971312345600" ]
]; #
fhir:Device.udiCarrier [
fhir:index 0;
fhir:Device.udiCarrier.deviceIdentifier [ fhir:value "A9999XYZ100T0474" ];
fhir:Device.udiCarrier.issuer [ fhir:value "http://hl7.org/fhir/NamingSystem/iccbba-other" ];
fhir:Device.udiCarrier.jurisdiction [ fhir:value "http://hl7.org/fhir/NamingSystem/fda-udi" ]
]; #
fhir:Device.status [ fhir:value "inactive"]; #
fhir:Device.manufacturer [ fhir:value "Acme Devices, Inc"]; #
fhir:Device.manufactureDate [ fhir:value "2013-02-01"^^xsd:date]; #
fhir:Device.expirationDate [ fhir:value "2014-02-01"^^xsd:date]; # 013032 = this is the manufacturing date expressed in YYYDDD (three digit year, three digit day number)
fhir:Device.association [
fhir:index 0;
fhir:Device.association.status [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/device-associationstatus" ];
fhir:Coding.code [ fhir:value "attached" ]
]
];
fhir:Device.association.humanSubject [
fhir:Reference.reference [ fhir:value "Patient/example" ]
]
]] . # 014032 = this is the expiration date expressed in YYYDDD (three digit year, three digit day number)
# - ontology header ------------------------------------------------------------
[a owl:Ontology;
owl:imports fhir:fhir.ttl] .
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the
examples are correct and useful, but they are not a normative part
of the specification.